BRITISH MEDICAL AUCTIONS November 2023 Endoscopy (#787) 03/11/2023 1:30 PM GMT - 10/11/2023 2:14 PM GMT CLOSED Starts Ending 10/11/2023 10:06 AM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 132. Previous|12|Next Lot 1 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 800547* View details Winning BidN/A Lot 2 Pentax FNL-10RBS Pharyngoscope Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN G11775* View details Winning BidN/A Lot 3 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 0 Broken Fibers Dirt in Optics , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 800574* View details Winning BidN/A Lot 4 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, *SN 2825028* View details Winning BidN/A Lot 5 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System Over 40 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, *SN View details StatusUnsold Lot 6 Olympus ENF-GP Pharyngoscope - Engineers Report : Optical System 10 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, *SN View details Winning BidN/A Lot 7 Olympus ENF-GP Pharyngoscope - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, *SN 700595* View details Winning BidN/A Lot 8 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 3 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, *SN 800548* View details Winning BidN/A Lot 9 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, *SN 800531* View details Winning BidN/A Lot 10 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 3 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, *SN 800568* View details Winning BidN/A Lot 11 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, *SN View details Winning BidN/A Lot 12 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 1 Broken Fiber , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, *SN View details Winning BidN/A Lot 13 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2311792* View details Winning BidN/A Lot 14 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Wrinkled, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN View details Winning BidN/A Lot 15 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2311809* View details Winning BidN/A Lot 16 Olympus PCF-Q260AL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 23170703* View details Winning BidN/A Lot 17 Job Lot of Scopes Including 1 x Olympus GIF-XQ Gastroscope, 1 x Olympus CF-IBW Colonoscope and 1 x Olympus BF-582 Bronchoscope (All for Spares and Repairs) View details Winning BidN/A Lot 18 Olympus CF-240AL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2210499* View details Winning BidN/A Lot 19 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2236029* View details Winning BidN/A Lot 20 Olympus ENF-GP Pharyngoscope in Case - Engineers Report : Optical System Over 30 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W404899* View details Winning BidN/A Lot 21 Pentax FI-10BS Laryngoscope in Case (Dismantled Condition) - Engineers Report : Optical System No Focus , Angulation - Strained, Insertion Tube - Torn *sn a01186*(IPS) View details Winning BidN/A Lot 22 Olympus CF-Q240L Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained , Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900347* View details Winning BidN/A Lot 23 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2033710* View details Winning BidN/A Lot 24 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2033649* View details Winning BidN/A Lot 25 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2032195* View details Winning BidN/A Lot 26 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2235251* View details Winning BidN/A Lot 27 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2033727* View details Winning BidN/A Lot 28 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900398* View details Winning BidN/A Lot 29 Olympus CYF-5 Cystoscope In Case - Engineer's Report : Optical System - Bad Fluid Stain , Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 500924* View details StatusUnsold Lot 30 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 2 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, *SN 011373* View details Winning BidN/A Lot 31 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900450* View details Winning BidN/A Lot 32 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2141287* View details Winning BidN/A Lot 33 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2140801* View details Winning BidN/A Lot 34 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2000480* View details Winning BidN/A Lot 35 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2100555* View details Winning BidN/A Lot 36 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2000750* View details Winning BidN/A Lot 37 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted , Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900424*( View details Winning BidN/A Lot 38 Olympus GIF-2T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained , Insertion Tube - Minor Kink , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 39 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System Minor Stain , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, *SN 512478* View details Winning BidN/A Lot 40 Olympus LF GP Laryngoscope in Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1000932* View details Winning BidN/A Lot 41 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2243098* View details Winning BidN/A Lot 42 Olympus BF-1T60 Bronchoscope in Case - Engineers Report : Optical System Minor Stain , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 2801422* View details Winning BidN/A Lot 43 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2142233* View details Winning BidN/A Lot 44 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2000741* View details Winning BidN/A Lot 45 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2146790* View details Winning BidN/A Lot 46 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2243191* View details Winning BidN/A Lot 47 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900444* View details Winning BidN/A Lot 48 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2243191* View details Winning BidN/A Lot 49 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2141290* View details Winning BidN/A Lot 50 Olympus LF-TP Laryngoscope in Case - Engineers Report : Optical System Excessive Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 700531* View details StatusUnsold Lot 51 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2700675* View details Winning BidN/A Lot 52 Olympus ENF-GP laryngoscope in Case - Engineers Report : Optical System Fluid Stain , Angulation - No Fault Found, Insertion Tube - Badly Kinked , Light Transmission - No Fault Found, Channels - No Fault Found *SN View details Winning BidN/A Lot 53 Olympus BF-260 Video Bronchoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2002699* View details Winning BidN/A Lot 54 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 200745* View details StatusUnsold Lot 55 Olympus LF GP Laryngoscope in Case - Engineers Report : Optical System - Fluid Stain , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1201919* View details Winning BidN/A Lot 56 Olympus LF-TP Laryngoscope in Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1102025* View details Winning BidN/A Lot 57 Olympus LF-TP Laryngoscope in Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 700524* View details Winning BidN/A Lot 58 Olympus BF-P60 Bronchoscope in Case - Engineers Report : Optical System 2 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 2802146* View details Winning BidN/A Lot 59 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900442* View details Winning BidN/A Lot 60 Olympus TJF-260V Video Duodenoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2101502 View details Winning BidN/A Lot 61 Olympus LF-TP Laryngoscope in Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 700522* View details Winning BidN/A Lot 62 Olympus BF-260 Video Bronchoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2102984* View details Winning BidN/A Lot 63 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2000749* View details Winning BidN/A Lot 64 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2243096* View details Winning BidN/A Lot 65 Olympus LF-GP Laryngoscope in Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 50064* View details Winning BidN/A Lot 66 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2000747* View details Winning BidN/A Lot 67 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - Intermittent Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2000743* View details StatusUnsold Lot 68 Olympus LF-TP Laryngoscope in Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 7000530* View details Winning BidN/A Lot 69 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Minor Kink , Light Transmission - No Fault Found, Channels - No Fault Found *SN 800524* View details Winning BidN/A Lot 70 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - Freeze Frame Inoperable , Angulation - Not Reaching Specification- To Be Adjusted, Insertion Tube - Wrinkled, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2510253* View details Winning BidN/A Lot 71 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2000748* View details Winning BidN/A Lot 72 Olympus BF-P60 Bronchoscope in Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 2802070* View details Winning BidN/A Lot 73 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2040495* View details Winning BidN/A Lot 74 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900449* View details Winning BidN/A Lot 75 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900451* View details Winning BidN/A Lot 76 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900446* View details Winning BidN/A Lot 77 Olympus BF-1T260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2001709* View details Winning BidN/A Lot 78 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2200676* View details Winning BidN/A Lot 79 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900445* View details Winning BidN/A Lot 80 Olympus BF-260 Video Bronchoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2102297* View details Winning BidN/A Lot 81 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Tube Has Minor Kink, Channels - No Fault Found, Leak Check - No Fault Found *SN 2141280* View details Winning BidN/A Lot 82 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2260677* View details Winning BidN/A Lot 83 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 200754* View details Winning BidN/A Lot 84 Olympus CF-H260DL Video Colonoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2200678* View details Winning BidN/A Lot 85 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2142373* View details Winning BidN/A Lot 86 Karl Storz AIDA NEO Control Unit *HDD Removed* (Powers Up) *SN KSK21367* View details StatusUnsold Lot 87 Olympus PCF-240L Video Colonoscope in Case - Engineer's Report : Optical System - Misty View , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN2900101* View details Winning BidN/A Lot 88 Olympus MH-908 Ultrasonic Probe In Case - Engineer's Report : Optical System - Unable to Check , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN1500036* View details StatusUnsold Lot 89 Pentax FNL-10RBS Laryngoscope In Case - Engineers Report : Optical System 2 Broken Fibers, Angulation - Down Angulation Broken, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *SN G111558* View details StatusUnsold Lot 90 Olympus CYF-4 Cystoscope in Case - Engineers Report : Optical System Misty View Over 50 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Crush Marks, Stained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 203740* View details StatusUnsold Lot 91 Olympus HYF Type XP Hysteroscope In Case - Engineers Report : Optical System Excess Broken Fibers , Angulation - No Fault Found, Insertion Tube - Dull, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 92 Olympus GF-UM2000 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Unable to Check Ultrasound Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1310304* View details StatusUnsold Lot 93 Olympus CYF-240 Video Cystoscope *Mfd 2014* in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - No Fault Found , Insertion Tube - Bending Section Rubber Split, Tube Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check *SN 2860606* View details StatusUnsold Lot 94 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Bending Section Rubber Split, Tube Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check *2860606* (RI) View details StatusUnsold Lot 95 Smith & Nephew Ref 7205928 30 Degree Autoclavable Video Arthroscope - Engineer's Report : Optical System - Unable to Test, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN XH30187* View details Winning BidN/A Lot 96 Smith & Nephew Ref 7210716 30 Degree Multimode Video Arthroscope - Engineer's Report : Optical System - Unable to Test, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN XR3960* View details Winning BidN/A Lot 97 Pentax FNL-10RBS Pharyngoscope - Engineer's Report : Optical System - 4 Broken Fibres, Angulation - Kinked and Perforated, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - NLeaking Insertion Tube *SN A010291* View details Winning BidN/A Lot 98 Pentax FNL-10RBS Rhinolaryngoscope - Engineer's Report : Optical System - Fluid and Dirt Stain , Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - Tube Leak *SN G111845* View details StatusUnsold Lot 99 Xion EF-N Pharyngoscope - Engineer's Report : Optical System - Fluid Stain, Angulation - Stained, Insertion Tube - Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 05725* View details Winning BidN/A Lot 100 Olympus TJF-260V Video Duodenoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2101360* View details Winning BidN/A Items per page 102550100 Previous|12|Next Previous 12 Next Previous 12 Next