BRITISH MEDICAL AUCTIONS February 2025 Endoscopy (#1083) 14/02/2025 2:00 PM GMT - 21/02/2025 3:22 PM GMT CLOSED Starts Ending 21/02/2025 1:00 PM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-72 of 72. Previous|1|Next Lot 1 Vision Sciences CST-5000 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *850618* View details StatusUnsold Lot 2 Vision Sciences CST-5000 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *850615* View details StatusUnsold Lot 3 Vision Sciences CST-5000 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *850614* View details StatusUnsold Lot 4 Olympus WA50015L 45 Degree NTSC Video Laparoscope in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *601945* View details StatusUnsold Lot 5 Olympus GF-UM2000 Video Ultrasound Gastroscope in Case - Engineer's Report : Optical System - CCD Image Ok, Unable to Check Ultrasound Image, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1410342* View details Winning BidN/A Lot 6 Olympus GF-UM2000 Video Ultrasound Gastroscope in Case - Engineer's Report : Optical System - Function Head Inoperative, CCD Image Ok, Unable to Check Ultrasound Image, Angulation - Not Reaching Specification, To Be Adjusted, L/R Brake Faulty, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1630619* View details Winning BidN/A Lot 7 Vision Sciences CST-5000 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *850103* View details StatusUnsold Lot 8 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2400921* View details Winning BidN/A Lot 9 24 x Pentax Endoscope Caps View details StatusUnsold Lot 10 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2100789* View details Winning BidN/A Lot 11 Toshiba PEF-510SB Ultrasound Endoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kink Marks Present, Leak Check - Unable to Check *1582082* View details StatusUnsold Lot 12 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300855* View details Winning BidN/A Lot 13 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2100788* View details Winning BidN/A Lot 14 Olympus XGIF-N240Y1 Prototype Gastroscope - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A14323* View details Winning BidN/A Lot 15 Karl Storz 11004 BCI Bronchoscope - Engineer's Report : Optical System - Severe Fluid Stain Present, Unable to Count Broken Fibers Due to Jammed Eyepiece Preventing Focus, Angulation - Strained and Stiff MOvement, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak from Body *87498* View details StatusUnsold Lot 16 Olympus BF-1T260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *280114* View details Winning BidN/A Lot 17 Olympus BF-1T260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2801101* View details Winning BidN/A Lot 18 Olympus BF-260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2501077* View details Winning BidN/A Lot 19 Olympus TJF-260V Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Catch in Raiser Control, Leak Check - No Fault Found *2700345* View details Winning BidN/A Lot 20 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710674* View details Winning BidN/A Lot 21 Olympus BF-3C40 Bronchoscope in Case - Engineer's Report : Optical System - Minor Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Kink at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1210780* View details Winning BidN/A Lot 22 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault FOund, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930470* View details Winning BidN/A Lot 23 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 29A461* View details Winning BidN/A Lot 24 Olympus LF-2 Laryngoscope - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found , Insertion Tube - Kinked at Grip , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2512784* View details Winning BidN/A Lot 25 Olympus BF-XT30 Fiber Bronchoscope - Engineer's Report : Optical System - Broken Fibers, Angulation - No Fault Found , Insertion Tube - Kinked at Grip and Minor Crush , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2500617* View details StatusUnsold Lot 26 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - Not Reaching Specification - To be Adjusted, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2512102* View details Winning BidN/A Lot 27 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900422* View details Winning BidN/A Lot 28 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN View details Winning BidN/A Lot 29 Olympus MH-247 Ultrasonic Probe Set - Engineers Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 1911499* View details StatusUnsold Lot 30 Olympus ENF-P4 Pharyngoscope in Case - Engineer's Report : Optical SYstem - 5 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *W211977* View details Winning BidN/A Lot 31 Olympus ENF-GP Pharyngoscope with Mini Light Source - Engineer's Report : Optical System - 2 x Broken Fibers and Minor Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found, Other Comments - Light Source Untested Due to No Batteries *W901736* View details Winning BidN/A Lot 32 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 33 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 34 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 35 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 36 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 37 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - Not Reaching Specification - Strained Bending Section, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W040685* View details Winning BidN/A Lot 38 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400267* View details StatusUnsold Lot 39 10 x Given Imaging PillCam Colon 2 Capsules (All Like New in Box) View details StatusUnsold Lot 40 10 x Given Imaging PillCam Colon 2 Capsules (All Like New in Box) View details StatusUnsold Lot 41 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault FOund, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2830415* View details Winning BidN/A Lot 42 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault FOund, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930499* View details Winning BidN/A Lot 43 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault FOund, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2830414* View details Winning BidN/A Lot 44 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault FOund, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930467* View details Winning BidN/A Lot 45 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Left / Right Brake Faulty, Insertion Tube - No Fault FOund, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930467* View details Winning BidN/A Lot 46 Olympus TJF-200 Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Other Comments - Case Inserts Perished *2500493* View details Winning BidN/A Lot 47 Olympus TJF-260V Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700337* View details Winning BidN/A Lot 48 Olympus BF-1T260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Case Inserts Perishing *1500380* View details Winning BidN/A Lot 49 Pentax FNL-10RBS Laryngoscope in Case - Engineer's Report : Optical Systems - 25 x Broken Fibers and Heavy Fluid Stain Present, Angulation - Crushed Bending Section, Insertion Tube - Totally Collapsed, Light Transmission - No Fault Found, Leak Check - Leak from Insertion Tube *G110924* View details Winning BidN/A Lot 50 Pentax EC38-I10F Video Colonoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A110290* **BRENT** View details Winning BidN/A Lot 51 Pentax EC34-I10F Video Colonoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Play Evident, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A110098* **BRENT** View details Winning BidN/A Lot 52 Pentax EG27-I10 Video Gastroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Strained, Insertion Tube - Worn and Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A110266* **BRENT** View details Winning BidN/A Lot 53 Pentax EC-2990LI Video Colonoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Worn Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H110171* **BRENT** View details Winning BidN/A Lot 54 Pentax EC38-I10F Video Colonoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A110259* **BRENT** View details Winning BidN/A Lot 55 Pentax EG29-I10 Video Gastroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G110557* **BRENT** View details Winning BidN/A Lot 56 Pentax FB-18V Bronchoscope in Case - Engineer's Report : Optical System - 5 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Worn, Light Transmission - Light Guide Tube Torn at Plug, Channels - No Fault Found, Leak Check - Leak from Light Guide Tube *A110446* View details Winning BidN/A Lot 57 Olympus LF-GP Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1101199* View details Winning BidN/A Lot 58 Pentax ECY-1575K Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G120141* **BRENT** View details Winning BidN/A Lot 59 Pentax ECY-1575K Video Cystoscope in Case - Engineer's Report : Optical System - Out of Focus, Angulation - No Fault Found, Insertion Tube - Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G120134* **BRENT** View details Winning BidN/A Lot 60 Pentax EG27-I10 Video Gastroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A110259* **BRENT** View details Winning BidN/A Lot 61 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2030102* View details Winning BidN/A Lot 62 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Image, Angulation - Not Reaching Specification, Left / Right Brake Faulty, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2100012* View details Winning BidN/A Lot 63 Olympus BF-40 Bronchoscope in Case - Engineer's Report : Optical System - Over 300 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1130410* View details Winning BidN/A Lot 64 Karl Storz 11301 BNX Video Intubation Scope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Leak From Insertion Tube *75797* View details Winning BidN/A Lot 65 Karl Storz 11009 BCI Bronchoscope in Case - Engineer's Report : Optical System - 3 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked and Leaking Due to Missing Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Leak from Insertion Tube *2192411* View details StatusUnsold Lot 66 Karl Storz 11101 RP2 Pharyngoscope in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - Severely Crushed, Not Angled Due to Damage, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Leak From Insertion Tube *2816203* View details Winning BidN/A Lot 67 Karl Storz 11272 AA Cystoscope in Case - Engineer's Report : Optical System - Severe Fluid Stain and Missing Eyepiece, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak From Eyepiece *37642* View details StatusUnsold Lot 68 Karl Storz 11101 VP Video Pharyngoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Leak From Insertion Tube *14346* View details Winning BidN/A Lot 69 Karl Storz 11101 VP Video Pharyngoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kink at Grip, Light Transmission - No Fault Found, Leak Check - No Fault Found *111241* View details Winning BidN/A Lot 70 Karl Storz 11001 RP Pharyngoscope with Light Guide Tube and Leak Tester in Case - Engineer's Report : Optical System - Over 100 Broken Fibers and Fluid Stain Present, Angulation - Crush in Bending Section, Very Stiff, Insertion Tube - Bending Section Rubber Torn and Leaking, Light Transmission - No Fault Found, Leak Check - Leak from Insertion Tube *59557* View details Winning BidN/A Lot 71 Karl Storz 11101 VP Video Pharyngoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Torn Bending Section Rubber, Leak Check - Leak From Insertion Tube *14325* View details Winning BidN/A Lot 72 Olympus ENF-GP Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Rucked, Leaking Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Leak From Insertion Tube *2503499* View details StatusUnsold Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next