BRITISH MEDICAL AUCTIONS February 2024 Endoscopy Equipment (#843) 08/02/2024 11:00 AM GMT - 19/02/2024 3:40 PM GMT CLOSED Starts Ending 19/02/2024 10:00 AM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 168. Previous|12|Next Lot 1 Linvatec HD4300 Autoclave 30 Degree Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 2 Richard Wolf 8880.543 30 Degree Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found with Richard Wolf 8885.011 Sheath View details Winning BidN/A Lot 3 Karl Storz 27301B 30 Degree Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 4 Olympus WA53000A 0 Degree Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 5 Stryker 502-539-010 0 Degree Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details StatusUnsold Lot 6 Conmed HD5500 0 Degree Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 7 Karl Storz 1032A DA 90 Degree Bronchoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 8 Dyonics 7207947 0 Degree Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 9 Conmed HD5500 0 Degree Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 10 Conmed HD5500 0 Degree Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 11 Richards 30 Degree 70230914 Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 12 ACMI FO-8168D 0 Degree Cystoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details StatusUnsold Lot 13 ACMI FO-8168M 30 Degree Cystoscope - Engineer's Report : Optical System - Cloudy, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details StatusUnsold Lot 14 Richard Wolf 8712402 0 Degree Urethroscope - Engineer's Report : Optical System - Slightly Cloudy, Insertion Tube - Bent, Light Transmission - No Fault Found, View details Winning BidN/A Lot 15 Circon Acmi 70 Degree Cystoscope - Engineer's Report : Optical System - Half Image Missing, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details StatusUnsold Lot 16 Circon Acmi 30 Degree Cystoscope - Engineer's Report : Optical System - Half Image Missing, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details StatusUnsold Lot 17 Circon Acmi 70 Degree Cystoscope - Engineer's Report : Optical System - Cloudy, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 18 Circon Acmi 0 Degree Cystoscope - Engineer's Report : Optical System - Cloudy, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 19 Stryker 0502-503-101 0 Degree Laparoscope - Engineer's Report : Optical System - No Fault Found , Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 20 Stryker 502-743-010 0 Degree Cystoscope - Engineer's Report : Optical System - Blurry, Insertion Tube - Bent, Light Transmission - No Fault Found, View details Winning BidN/A Lot 21 Karl Storz 7200 A 0 Degree Arthroscope - Engineer's Report : Optical System - Obscured Vision - Blurry , Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 22 Karl Storz 62043 A 0 Degree Laparoscope - Engineer's Report : Optical System - No Fault Found , Insertion Tube - No Fault Found, Light Transmission - No Fault Found, View details Winning BidN/A Lot 23 Olympus GF-UM2000 Ultrasound Video Gastroscope - Engineer's Report : Optical System - Image ok But Function Buttons Inoperable , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1530535* View details Winning BidN/A Lot 24 Machida ENT-30F Pharyngoscope in Case - Engineer's Report : Optical System - Fluid Stain Obscuring Image, Angulation - No Fault Found, Insertion Tube - Minor Crush , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details StatusUnsold Lot 25 Pentax FNL-10RP3 Rhinolaryngoscope - Engineer's Report : Optical System - Heavy Fluid Stain, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN G116154* View details StatusUnsold Lot 26 Olympus HYF Type XP Hysteroscope In Case - Engineer's Report : Optical System - Excess Broken Broken Fibres and Fluid Stain, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W401368* View details Winning BidN/A Lot 27 Olympus HYF Type XP Hysteroscope In Case - Engineer's Report : Optical System - Fluid Stain Across Image, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W000762* View details Winning BidN/A Lot 28 Olympus HYF Type XP Hysteroscope In Case - Engineer's Report : Optical System - Over 100 Broken Fibres, Angulation - No Fault Found, Insertion Tube - Strained , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W900122* View details Winning BidN/A Lot 29 Smith & Nephew OL-1 Pharyngoscope - Engineer's Report : Optical System - Excess Broken Fibres and Heavy Fluid Stain, Angulation - No Fault Found, Insertion Tube - Rubber Grip Missing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details StatusUnsold Lot 30 Vision Sciences CST-5000 Video Cystoscope - Engineer's Report : Optical System - Unable To Check, Angulation - No Fault Found, Insertion Tube - Severed and Torn Near Body , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 31 Vision Sciences TNE-2000 Rhinolaryngoscope - Engineer's Report : Optical System - Totally Obscured By Fluid and Broken Fibres, Angulation - Bending Section Squashed , Insertion Tube - Strained, Light Transmission - Tube Severed, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 32 Vision Sciences SPV-7000 Probe - Engineers Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found View details StatusUnsold Lot 33 Olympus LF-TP Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibres , Angulation - No Fault Found, Insertion Tube - Crush Mark, Channels - No Fault Found *SN 201430* View details Winning BidN/A Lot 34 Pentax FNL-10RBS Laryngoscope In Case - Engineers Report : Optical System 2 Broken Fibers, Angulation - Down Angulation Broken, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *SN G111558* View details StatusUnsold Lot 35 DP Medical Stroboview 2000 Camera Control Unit View details Winning BidN/A Lot 36 Lapalux 429-67200 5.0mm 0 Degree Laparoscope - Engineers Report Optical System - No Image, Light Transmission - No Fault Found, Insertion Tube - Dented View details Winning BidN/A Lot 37 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A048* View details StatusUnsold Lot 38 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A071* View details StatusUnsold Lot 39 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A085* View details StatusUnsold Lot 40 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A052* View details Winning BidN/A Lot 41 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A116* View details StatusUnsold Lot 42 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A084* View details StatusUnsold Lot 43 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A096* View details StatusUnsold Lot 44 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A068* View details StatusUnsold Lot 45 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *135A087* View details StatusUnsold Lot 46 Downs Light Source Version 3.0 (Powers Up) View details Winning BidN/A Lot 47 Olympus Surgical CO2 Insufflator (Powers Up) View details Winning BidN/A Lot 48 Fujinon Unknown I.D Cystoscope - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 135029* View details StatusUnsold Lot 49 Karl Storz 11302BD2 Laryngoscope - Engineer's Report : Optical System - Over 60 Broken Fibres, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2223395* View details Winning BidN/A Lot 50 Karl Storz AIDA NEO Control Unit *HDD Removed* (Powers Up) *SN KSK21367* View details Winning BidN/A Lot 51 Unknown Manufacturer Camera View details Winning BidN/A Lot 52 Olympus CYF-240 Video Cystoscope - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2700475 View details Winning BidN/A Lot 53 Olympus ESG-100 Generator Software Version V2.11-A with 1 x Olympus Celon Footswitch II (Powers Up) View details Winning BidN/A Lot 54 Olympus Evis Lucera MAJ-1154 Pigtail Connector View details Winning BidN/A Lot 55 Olympus MAJ-901 Water Container in Box View details Winning BidN/A Lot 56 Olympus OEV191H HD LCD Monitor (Powers Up with Damage to Screen / Casing - See Photos) View details Winning BidN/A Lot 57 Smith and Nephew Dyonics Xenon XL Light Source (Powers Up) View details StatusUnsold Lot 58 Smith and Nephew Dyonics ED-3 Enhanced Digital 3-Chip Camera Control Unit (Powers Up) View details Winning BidN/A Lot 59 Olympus OEV261H High Definition LCD Endoscopy Monitor with AC Adaptor and Power Cable (Powers Up) View details Winning BidN/A Lot 60 Olympus OEV261H High Definition LCD Endoscopy Monitor with AC Adaptor (Powers Up with Stock Power Cable, Cable Not Included, Scratches to Screen - See Photos) View details Winning BidN/A Lot 61 20 x Ambu REF 477001000 aScope 4 Broncho Regular 5.0/2.2 Flexible Endoscopes (Exp 04-2023) View details Winning BidN/A Lot 62 20 x Ambu REF 477001000 aScope 4 Broncho Regular 5.0/2.2 Flexible Endoscopes (Exp 04-2023) *Stock Photo* View details Winning BidN/A Lot 63 20 x Ambu REF 477001000 aScope 4 Broncho Regular 5.0/2.2 Flexible Endoscopes (Exp 04-2023) *Stock Photo* View details Winning BidN/A Lot 64 20 x Ambu REF 477001000 aScope 4 Broncho Regular 5.0/2.2 Flexible Endoscopes (Exp 04-2023) *Stock Photo* View details Winning BidN/A Lot 65 20 x Ambu REF 477001000 aScope 4 Broncho Regular 5.0/2.2 Flexible Endoscopes (Exp 04-2023) *Stock Photo* View details Winning BidN/A Lot 66 10 x Ambu REF 477001000 aScope 4 Broncho Regular 5.0/2.2 Flexible Endoscopes (Exp 04-2023) View details Winning BidN/A Lot 67 Job Lot of Various Consumables *All Expired* View details Winning BidN/A Lot 68 Olympus IMH-20 Image Management System (Powers Up - HDD Removed) View details Winning BidN/A Lot 69 Olympus Evis Lucera MAJ-1154 Pigtail Connector View details Winning BidN/A Lot 70 Olympus OFP Endoscopic Flushing Pump (Powers Up with Damage to Casing - See Photos) *SN 27 21705* View details StatusUnsold Lot 71 Olympus EVIS Lucera Video System Center Model CV-260SL Unit (Powers Up) *SN 7722039* View details Winning BidN/A Lot 72 Job Lot Including 1 x Olympus EVIS CLV-260SL Xenon Light Source (Powers Up) and 1 x Olympus MAJ-1536 Keyboard *SN 7712018* View details Winning BidN/A Lot 73 Stryker Pneumo Sure XL High Flow Insufflator Unit (Powers Up, Requires Service) *SN 1509CE0369* View details Winning BidN/A Lot 74 Stryker SDC3 HD Information Management System (Powers Up) *SN 15E031854* View details Winning BidN/A Lot 75 Olympus ECS-260 Endoscopic Connector Cable View details Winning BidN/A Lot 76 Olympus ECS-260 Endoscopic Connector Cable View details Winning BidN/A Lot 77 Olympus EU-ME1 Universal Endoscopic Ultrasound Center with CV-290 Keyboard (Powers Up) View details StatusUnsold Lot 78 11 x Olympus Rigid Scope Cases View details Winning BidN/A Lot 79 12 x Olympus Rigid Scope Cases View details Winning BidN/A Lot 80 Pentax ED34-i10T Video Duodenoscope - Engineers Report : Optical System - Unable to Check , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN A110128* View details Winning BidN/A Lot 81 Olympus GIF-XQ240 Video Gastroscope - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification - To Be Adjusted , Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2336558* View details Winning BidN/A Lot 82 Olympus GIF-H260 Video Gastroscope - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2243380* View details Winning BidN/A Lot 83 Olympus CF-Q240L Colonoscope - Engineers Report : Optical System - Head Malfunction , Angulation - Bending Section Rubber Badle Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2800089* View details Winning BidN/A Lot 84 Olympus GIF-XQ240 Video Gastroscope - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2913510* View details Winning BidN/A Lot 85 Olympus CF-240L Video Colonoscope - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2930097* View details Winning BidN/A Lot 86 Olympus CYF-200 Video Cystoscope - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - Kinked with Minor Ripples , Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 1010307* View details Winning BidN/A Lot 87 Olympus CF-240L Video Colonoscope - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification - To Be Adjusted , Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2800246* View details Winning BidN/A Lot 88 Olympus GIF-XP240 Video Gastroscope - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2030268* View details Winning BidN/A Lot 89 Olympus CF-240L Video Colonoscope - Engineers Report : Optical System - No Fault Found , Angulation - Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 203097* View details Winning BidN/A Lot 90 Olympus CYF-240 Video Cystoscope - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 290704* View details Winning BidN/A Lot 91 Olympus CYF-4 Cystoscope - Engineer's Report : Optical System - Severe Fluid Stain, Angulation - No Fault Found, Insertion Tube - Kinded, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details StatusUnsold Lot 92 Olympus LF-GP Laryngoscope - Engineer's Report : Optical System - 7 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Indentations, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN View details Winning BidN/A Lot 93 Olympus CYF- 4 Cystoscope - Engineer's Report : Optical System - Dirt Particle In Optics, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details StatusUnsold Lot 94 Olympus CYF- 4 Cystoscope - Engineer's Report : Optical System - Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 190027* View details Winning BidN/A Lot 95 Olympus CYF- 4 Cystoscope - Engineer's Report : Optical System - Fluid Stain Across Image, Angulation - Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details StatusUnsold Lot 96 Olympus CYF-5A Cystoscope - Engineer's Report : Optical System - Over 30 Broken Fibers, Angulation - Strained, Insertion Tube - Kink Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W600805* View details StatusUnsold Lot 97 Richard Wolf 7305.006 Cystoscope - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - Crush Mark, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 98 Olympus CF-Q260DL Video Colonoscope - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2510215* View details Winning BidN/A Lot 99 Olympus ENF-P4 Pharyngoscope - Engineer's Report : Optical System - 0 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kink Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2825056* View details Winning BidN/A Lot 100 Olympus ENF-P4 Pharyngoscope - Engineer's Report : Optical System - 0 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kink, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 910968* View details Winning BidN/A Items per page 102550100 Previous|12|Next Previous 12 Next Previous 12 Next