BRITISH MEDICAL AUCTIONS November 2023 Endoscopy Equipment Part 2 (#794) 14/11/2023 5:30 PM GMT - 20/11/2023 5:34 PM GMT CLOSED Starts Ending 20/11/2023 1:00 PM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 138. Previous|12|Next Lot 1 Smith & Nephew Smith & Nephew 72202959 HD 4mm 30 Degree Autoclavable Video Arthroscope - Engineers Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN (21)CCF1444126* View details Winning BidN/A Lot 2 Oscar 0 Degree Autoclave Laparoscope - Engineers Report : Optical System - Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN 1667* View details Winning BidN/A Lot 3 Vision Sense A134 Video Arthroscope - Engineers Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN View details Winning BidN/A Lot 4 ACMI FO-8168M 30 Degree Cystoscope - Engineers Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 5 Stryker 92010664LP 0 Degree Laparoscope - Engineers Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN View details Winning BidN/A Lot 6 Karl Storz 26003 BA Hopkins II 30 Degree Autoclavable Laparoscope - Engineers Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN View details Winning BidN/A Lot 7 3M 81022N 3mm 30 Degree Endoscope - Engineers Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN View details Winning BidN/A Lot 8 Olympus A3765A 30 Degree Cystoscope - Engineers Report : Optical System - Obstructed , Light Transmission - No Fault Found, Insertion Tube - Bent *SN 800025* View details Winning BidN/A Lot 9 Dyonics 4mm 30 Degree Arthroscope - Engineers Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - Dents *SN 557462* View details Winning BidN/A Lot 10 ACMI F0-8168M 30 Degree Cystoscope - Engineers Report : Optical System - Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN View details Winning BidN/A Lot 11 Karl Storz 27005 BA Cystoscope - Engineers Report : Optical System - Obstructed View, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN 123PSJ View details Winning BidN/A Lot 12 Gynecare 4mm 0 19356 30 Degree Cystoscope - Engineers Report : Optical System - No Image , Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 13 Gynecare 4mm 0 19356 30 Degree Cystoscope - Engineers Report : Optical System - Slightly Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 14 R.Wolf 10mm 130 Degree Laparoscope - Engineers Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 15 Olympus WA50024B Endoeye LS 30 Degree Laparoscope - Engineers Report : Optical System - Unable to Check, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *SN 606393* View details Winning BidN/A Lot 16 ORLVISION Rs1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 17 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 18 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 19 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 20 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 21 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 22 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 23 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 24 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 25 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 26 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 27 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 28 ORLVISION RX1 Video Rhino-Laryngoscope (Untested) View details Winning BidN/A Lot 29 Fujinon EG-530FP Video Gastroscope in Case - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 314096* View details Winning BidN/A Lot 30 Fujinon EG-530FP Video Gastroscope in Case - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 314097* View details Winning BidN/A Lot 31 Fujinon EC-530FL Video Colonoscope - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 496145* View details Winning BidN/A Lot 32 Fujinon EG-530FP Video Gastroscope in Case - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 314098* View details Winning BidN/A Lot 33 Fujinon EC-530FL Video Colonoscope - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 496143* View details Winning BidN/A Lot 34 Fujinon EC-530FL Video Colonoscope - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 96A154* View details Winning BidN/A Lot 35 Fujinon EG-530FP Video Gastroscope in Case - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 314018* View details Winning BidN/A Lot 36 Fujinon EC-530FL Video Colonoscope - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 496153* View details Winning BidN/A Lot 37 Fujinon EG-530FP Video Gastroscope in Case - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 314069* View details Winning BidN/A Lot 38 Fujinon EG-530FP Video Gastroscope in Case - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 314070* View details Winning BidN/A Lot 39 Fujinon EC-530FL Video Colonoscope - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 496148* View details Winning BidN/A Lot 40 Fujinon EG-530FP Video Gastroscope in Case - Engineers Report : Optical System - Reported To Be In Working Order, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 314099* View details Winning BidN/A Lot 41 Vision Sciences SPV-7000 Probe - Engineers Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found View details StatusUnsold Lot 42 Karl Storz 11302 BDD2 Flexible Video Laryngoscope in Carry Case - Engineer's Report : Optical System - 2 Broken Fibres, Angulation - No Fault Found, Insertion Tube - No Fault Found *2206503* View details Winning BidN/A Lot 43 Karl Storz 11302 BDD2 Flexible Video Laryngoscope in Carry Case - Engineer's Report : Optical System - 0 Broken Fibres , Angulation - No Fault Found, Insertion Tube - No Fault Found, Channels - No Fault Found *SN2177644* View details Winning BidN/A Lot 44 Olympus LF-TP Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibres , Angulation - No Fault Found, Insertion Tube - Crush Mark, Channels - No Fault Found *SN 201430* View details StatusUnsold Lot 45 Olympus CF-Q260DL Video Colonoscope- Engineers Report : Optical System - No Fault Found , Angulation - Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2311682* View details Winning BidN/A Lot 46 Olympus BF-240 Video Bronchoscope In Case- Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 1920062** View details Winning BidN/A Lot 47 Olympus BF-240 Video Bronchoscope In Case- Engineers Report : Optical System - Blurred Vision , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN View details Winning BidN/A Lot 48 Olympus BF-240 Video Bronchoscope In Case- Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2800313* View details Winning BidN/A Lot 49 Olympus CF Q16OL Video Colonoscope In Case- Engineers Report : Optical System - Unable to Check, Angulation - Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2205525* View details Winning BidN/A Lot 50 Olympus CYF Type V2 Video Cystoscope - Engineers Report : Optical System - Unable to Check , Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 040756* View details Winning BidN/A Lot 51 MSI Pharyngoscope- Engineers Report : Optical System - Severe Fluid Stain, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 45365* View details StatusUnsold Lot 52 Olympus MH-908 Ultrasonic Probe In Case - Engineer's Report : Optical System - Unable to Check , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN1500036* View details Winning BidN/A Lot 53 Pentax FNL-10RBS Laryngoscope In Case - Engineers Report : Optical System 2 Broken Fibers, Angulation - Down Angulation Broken, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *SN G111558* View details StatusUnsold Lot 54 Olympus CYF-4 Cystoscope in Case - Engineers Report : Optical System Misty View Over 50 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Crush Marks, Stained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 203740* View details Winning BidN/A Lot 55 Olympus GF-UM2000 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Unable to Check Ultrasound Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1310304* View details Winning BidN/A Lot 56 Olympus CYF-240 Video Cystoscope *Mfd 2014* in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - No Fault Found , Insertion Tube - Bending Section Rubber Split, Tube Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check *SN 2860606* View details Winning BidN/A Lot 57 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Bending Section Rubber Split, Tube Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check *2860606* (RI) View details Winning BidN/A Lot 58 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2300581* View details StatusUnsold Lot 59 Olympus GIF-N230 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation -Excessive Play , Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2310388* View details Winning BidN/A Lot 60 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - Intermittent Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2000743* View details StatusUnsold Lot 61 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 200745* View details StatusUnsold Lot 62 Olympus LF-TP Laryngoscope in Case - Engineers Report : Optical System Excessive Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 700531* View details Winning BidN/A Lot 63 Olympus CYF-5 Cystoscope In Case - Engineer's Report : Optical System - Bad Fluid Stain , Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 500924* View details Winning BidN/A Lot 64 Olympus LF GP Laryngoscope in Case - Engineers Report : Optical System Minor Stain , Angulation - No Fault Found, Insertion Tube - Badly Crushed , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1000932* View details Winning BidN/A Lot 65 Pentax FNL-10RBS Rhinolaryngoscope - Engineer's Report : Optical System - Fluid and Dirt Stain , Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - Tube Leak *SN G111845* View details StatusUnsold Lot 66 Olympus ENF-P4 Pharyngoscope - Engineers Report : Optical System Over 40 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, *SN View details Winning BidN/A Lot 67 Karl Storz 200461 20 AIDA Control NEO Unit *HDD Removed* (Powers Up) View details Winning BidN/A Lot 68 Viking 3911010 Camera Head View details Winning BidN/A Lot 69 2 x Olympus HPU-20 Heat Probe Units (Both Power Up with E1 Message) View details Winning BidN/A Lot 70 Stryker Sidne Voice Activation System (Powers Up) View details Winning BidN/A Lot 71 Karl Storz Endoskope 207111 20 SCB unidrive GYN Console (Powers Up, with E11 Message) View details Winning BidN/A Lot 72 Annexart Celt 0000-610 Laparoscopic Light Source (Powers Up with Good Bulb) View details StatusUnsold Lot 73 DP Medical Stroboview 2000 Camera Control Unit View details StatusUnsold Lot 74 Olympus PCF-Q260AL Video Colonoscope In Case- Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification - Bending Section Distorted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 281413* View details Winning BidN/A Lot 75 Olympus GIF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2958675* View details Winning BidN/A Lot 76 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2411989* View details Winning BidN/A Lot 77 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - No Fault Found , Not Reaching Specification Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 24122016* View details Winning BidN/A Lot 78 Olympus GIF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2644935* View details Winning BidN/A Lot 79 Olympus GIF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2645794* View details Winning BidN/A Lot 80 Olympus PCF-Q260AL Video Colonoscope In Case - Engineers Report : Optical System - Blurred Image , Angulation - Not Reaching Specification Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2910476* View details Winning BidN/A Lot 81 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - Not Reaching Specification To Be Adjusted, Angulation - No Fault Found, Insertion Tube - Rubber Grip Split, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2411987* View details Winning BidN/A Lot 82 Olympus GIF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2857524* View details Winning BidN/A Lot 83 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - Not Reaching Specification To Be Adjusted , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2510223* View details Winning BidN/A Lot 84 Olympus GIF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2533013* View details Winning BidN/A Lot 85 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2311882* View details Winning BidN/A Lot 86 Olympus GIF-XQ260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2522115* View details Winning BidN/A Lot 87 Olympus GIF-XQ260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN2522115* View details Winning BidN/A Lot 88 Olympus GIF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - Minor Indentations, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2857616* View details Winning BidN/A Lot 89 Olympus GIF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2857763* View details Winning BidN/A Lot 90 Karl Storz 1129DE1 - Engineers Report : Optical System - Excessive Broken Fibre , Angulation - Strained, Insertion Tube - Bending Rubber Missing, Light Transmission - 30 % Loss View details Winning BidN/A Lot 91 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification Brake Knob Adrift , Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2811101 View details Winning BidN/A Lot 92 Olympus ENF-XP Pharyngoscope in Case - Engineers Report : Optical System - 3 Broken Fibres, Angulation - No Fault Found, insertion Tube - No Fault Found , Light Transmission - No Fault Found View details Winning BidN/A Lot 93 Olympus PCF-Q260AL Video Colonoscope - Engineers Report : Optical System - Not Reaching Specification To Be Adjusted , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN View details Winning BidN/A Lot 94 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2311887* View details Winning BidN/A Lot 95 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2710892* View details Winning BidN/A Lot 96 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Left Angulation Flexi Broken, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2811103* View details Winning BidN/A Lot 97 Olympus CF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification To Be Adjusted, Insertion Tube - Minor Indentation, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2957910* View details Winning BidN/A Lot 98 Olympus GIF-Q260 Video Gastroscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2857609* View details Winning BidN/A Lot 99 Olympus CF-Q260DL Video Colonoscope in Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2610572* View details Winning BidN/A Lot 100 Olympus PCF-Q260AL Video Colonoscope In Case - Engineers Report : Optical System - No Fault Found , Angulation - Not Reaching Specification To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 2801400* View details Winning BidN/A Items per page 102550100 Previous|12|Next Previous 12 Next Previous 12 Next