BRITISH MEDICAL AUCTIONS November 2023 Endoscopy (#787) 03/11/2023 1:30 PM GMT - 10/11/2023 2:14 PM GMT CLOSED Starts Ending 10/11/2023 10:06 AM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 101-132 of 132. Previous|12|Next Lot 101 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2510234* View details Winning BidN/A Lot 102 Olympus ENF-P4 Pharyngoscope In Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 412284* View details Winning BidN/A Lot 103 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN View details Winning BidN/A Lot 104 Olympus TJF-260V Video Duodenoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 210161* View details Winning BidN/A Lot 105 Karl Storz 1101RP Scope - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 90589* View details Winning BidN/A Lot 106 Olympus CF-240DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Strained, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2110220* (g) View details Winning BidN/A Lot 107 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2243396* (g) View details Winning BidN/A Lot 108 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2300581* View details StatusUnsold Lot 109 Olympus TJF-260V Video Duodenoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2001166* (g) View details Winning BidN/A Lot 110 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Wrinkled, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2811028* (g) View details Winning BidN/A Lot 111 Pentax EG-3270UK 2.8 Ultrasound Video Gastroscope in Case (Ultrasound Untested) - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN H1200284* View details Winning BidN/A Lot 112 Pentax EG-3270UK 2.8 Ultrasound Video Gastroscope in Case (Ultrasound Untested) - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Perforated, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN H20203* View details Winning BidN/A Lot 113 Olympus GIF-XP260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 114 Olympus GIF-N230 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation -Excessive Play , Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2310388* View details StatusUnsold Lot 115 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2236489* View details Winning BidN/A Lot 116 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900113* View details Winning BidN/A Lot 117 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2857705* View details Winning BidN/A Lot 118 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2522270* View details Winning BidN/A Lot 119 Olympus CF-240L Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2930040* View details Winning BidN/A Lot 120 Olympus LF GP Laryngoscope in Case - Engineers Report : Optical System Minor Stain , Angulation - No Fault Found, Insertion Tube - Badly Crushed , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1000932* View details StatusUnsold Lot 121 Olympus LF DP Laryngoscope - Engineer's Report : Optical System - Dirt In Optics, Angulation - No Fault Found, Insertion Tube - Crush Marks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 9000325* View details Winning BidN/A Lot 122 Olympus TJF-260V Video Duodenoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2201793* View details Winning BidN/A Lot 123 Olympus ENF-P4 Pharyngoscope In Case - Engineers Report : Optical System 1 Broken Fiber , Angulation - No Fault Found, Insertion Tube - Badly Strained , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1421166* View details Winning BidN/A Lot 124 Olympus ENF-P4 Pharyngoscope In Case - Engineers Report : Optical System Fluid Stain , Angulation - No Fault Found, Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found *SN View details Winning BidN/A Lot 125 Olympus ENF-P4 Pharyngoscope In Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1420955* View details Winning BidN/A Lot 126 Olympus ENF-P4 Pharyngoscope In Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1421112* View details Winning BidN/A Lot 127 Olympus ENF-P4 Pharyngoscope In Case - Engineers Report : Optical System 0 Broken Fibers , Angulation - No Fault Found, Insertion Tube - Minor Kink , Light Transmission - No Fault Found, Channels - No Fault Found *SN 1421118* View details Winning BidN/A Lot 130 Karl Storz 27005BA Cystoscope - Engineer's Report : Diameter - 4.0mm, Angle - 30 Degree, Length - 310, Optical Image - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 131 Karl Storz 27005B Cystoscope - Engineer's Report : Diameter - 4.0mm, Angle - 30 Degree, Length - 310, Optical Image - Damaged, Image Messy, Light Transmission - No Fault Found, Insertion Tube - Dented View details Winning BidN/A Lot 132 Karl Storz 27005BA Cystoscope - Engineer's Report : Diameter - 4.0mm, Angle - 30 Degree, Length - 310, Optical Image - Slightly Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 133 Karl Storz Hopkins II 27005B1A Cystoscope - Engineer's Report : Diameter - 4.0mm, Angle - 30 Degree, Length - 310, Optical Image - Clear Image Slightly Yellow, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 134 Henka - Sasswolf 719-970-0434 Cystoscope - Engineer's Report : Diameter - 4.0mm, Angle - 30 Degree, Length - 310, Optical Image - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Items per page 102550100 Previous|12|Next Previous 12 Next Previous 12 Next