June 2023 Endoscopy 31/05/2023 12:00 PM BST - 07/06/2023 3:21 PM BST View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 142. Previous|12|Next Image Lot # Item Title Time Left Your Bids 1 Pentax FNL-10RBS Pharyngoscope with BS-LH2 Mini Light Source in Case - Engineer's Report : Scope is in Dismantled Condition *G111148* 1 Winning BidN/AStatusSold View details 2 Pentax FNL-10RBS Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111158* 1 Winning BidN/AStatusSold View details 3 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2310715* 1 Winning BidN/AStatusSold View details 4 Olympus CYF-5A Cystoscope in Case - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *N/A* 1 Winning BidN/AStatusSold View details 5 Olympus CYF-5A Cystoscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - ETO Valve Loose *351401* 1 Winning BidN/AStatusSold View details 6 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2311830* 1 Winning BidN/AStatusSold View details 7 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2310717* 1 Winning BidN/AStatusSold View details 8 Olympus CYF-5A Cystoscope in Case - Engineer's Report : Optical System - Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *351402* 1 Winning BidN/AStatusSold View details 9 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2345827* 1 Winning BidN/AStatusSold View details 10 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Minor Leak from Angulation *2345284* 1 Winning BidN/AStatusSold View details 11 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Minor Leak from Angulation *2345288* 1 Winning BidN/AStatusSold View details 12 Olympus CYF-5A Cystoscope in Case - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *500125* 1 Winning BidN/AStatusSold View details 13 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2311831* 1 Winning BidN/AStatusSold View details 14 Olympus BF-P260F Video Bronchoscope in Case - Engineer's Report : Optical System - Stain Present, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *2600493* 1 Winning BidN/AStatusSold View details 15 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Minor Leak from Angulation *2557616* 1 Winning BidN/AStatusSold View details 16 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2512076* 1 Winning BidN/AStatusSold View details 17 Karl Storz 11302BD2 Laryngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak From Tube Due to No Bending Section Rubber *2178502* 1 Winning BidN/AStatusSold View details 18 Fujinon EG-530FP Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found * 1 Winning BidN/AStatusSold View details 19 Fujinon EC-530LP Video Colonoscope in Case - Engineer's Report : Optical System - Intermittent Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *657K051* 1 Winning BidN/AStatusSold View details 20 Pentax FNL-10RBS Pharyngoscope in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G114551* 1 Winning BidN/AStatusSold View details 21 Olympus CF-10L Colonoscope in Case - Engineer's Report : Optical System - Excess Broken Fibers and Heavy Fluid Stain Present, Angulation - Strained, Insertion Tube - Kinked, Leak Check - Leak From Plug 1 Winning BidN/AStatusSold View details 22 Olympus ENF-GP Pharyngoscope in Case - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *1402977* 1 Winning BidN/AStatusSold View details 23 Olympus ENF-P4 Pharyngoscope in Case - Engineer's Report : Optical System - 12 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *700246* 1 StatusUnsold View details 24 Olympus ENF-GP Pharyngoscope in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *1700690* 1 Winning BidN/AStatusSold View details 25 Karl Storz 11102CM Video Pharyngoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - Unable to Check *68275* 1 Winning BidN/AStatusSold View details 26 Karl Storz 11302BD2 Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 27 Karl Storz 11101D Video Pharyngoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *59825* 1 Winning BidN/AStatusSold View details 28 Karl Storz 11292AD1 Choledocoscope with Light Guide Tube in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 29 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2400330* 1 Winning BidN/AStatusSold View details 30 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - 3 x Broken Fibers, Angulation - Inoperative, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 31 Olympus GIF-XQ20 Gastroscope - Engineer's Report : 4 Broken Fibers, Angulation - Not Reaching Specification, Other Comments - Sticky Light Guide Tube and Stained 1 Winning BidN/AStatusSold View details 32 Olympus BF-P60 Bronchoscope - Engineer's Report : Optical System - Looks OK but Adapter Jammed onto Eyepiece Obscuring View, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - Minor Intermittent Leak from Channel 1 Winning BidN/AStatusSold View details 33 Fujinon EC-450LP5 Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *4C285A009* **GL** 1 Winning BidN/AStatusSold View details 34 Pentax FNL-10RP3 Pharyngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *141314* 1 Winning BidN/AStatusSold View details 35 Olympus BF-260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2701710* 1 Winning BidN/AStatusSold View details 36 Olympus BF-260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2701702* 1 Winning BidN/AStatusSold View details 37 Olympus BF-F260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700197* 1 Winning BidN/AStatusSold View details 38 Olympus LTF-VH Rigid Video Laparoscope - Engineer's Report : Optical Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 39 Unknown Manufacturer 70 Degree Arthroscope - Engineer's Report : Optical System- Yellowed, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 40 Job Lot Including 1 x Richards 30 Degree 70230914 Arthroscope - Engineer's Report : Optical System- No Image, Angulation - No Fault Found, Insertion Tube - Distorted, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, 1 x Explorent 30 Degree 830030 Arthroscope Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Poor Light, Channels - No Fault Found, Leak Check - No Fault Foun 1 StatusUnsold View details 41 Henke Sass Wolf 0 Degree Short Rigid Scope - Engineer's Report : Optical System- Cloudy, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 StatusUnsold View details 42 Richards 30 Degree 70230914 Arthroscope - Engineer's Report : Optical System- Yellowed, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Yellowed, Channels - No Fault Found, Leak Check - No Fault Found 1 StatusUnsold View details 43 Job Lot Including 1 x Wolf 30 Degree Arthroscope - Engineer's Report : Optical System- Cloudy, Angulation - No Fault Found, Insertion Tube - Distorted, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, 1 x Wolf 0 Degree Arthroscope - Engineer's Report : Optical System- No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 StatusUnsold View details 44 Henke Sass Wolf 70 Degree Scope in Case - Engineer's Report : Optical System- No Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 45 Stryker 0 Degree 502-555-010 Cystoscope - Engineer's Report : Optical System- No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 46 Stryker 0 Degree 502-457-010 Laparoscope - Engineer's Report : Optical System- No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 47 Stryker 0 Degree 502-457-010 Laparoscope - Engineer's Report : Optical System- No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 48 Karl Storz 27005 BA Hopkins II Cystoscope - Engineer's Report : Optical System- Poor Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 49 Karl Storz 26105BA 30 Degree Cystoscope - Engineer's Report : Optical System- No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 50 Stryker 502-457-010 0 Degree Laparoscope - Engineer's Report : Optical System- No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 51 Richard Wolf 8974.401 Cystoscope - Engineer's Report : Optical System - Very Poor Dark Image, Insertion Tube - Distorted, Light Transmission - No Fault Found 1 StatusUnsold View details 52 Stryker 502-205-030 Laparoscope - Engineer's Report : Optical System - Dark Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 53 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Bending Section Rubber Split, Tube Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check *2860606* (RI) 1 StatusUnsold View details 54 Xion EF-N Pharyngoscope - Engineer's Report : Optical System - Fluid Stain, Angulation - Stained, Insertion Tube - Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 05725* 1 StatusUnsold View details 55 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 45 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111178* 1 StatusUnsold View details 56 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 1 x Broken Fiber, 4 x Grey Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111753* 1 Winning BidN/AStatusSold View details 57 Vision Sciences ENT-2000 Rhinolaryngoscope - Engineer's Report : Optical System - Fluid Contamination, Angulation - Broken, Insertion Tube - Stripped Covering, Light Transmission - Poor 1 StatusUnsold View details 58 Visionsense 0 Degree Video Rigid Arthroscope with Light Guide Tube in Tray - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found (W) 1 Winning BidN/AStatusSold View details 59 Olympus ENF Type P4 Rhinolaryngoscope In Carry Case - Engineer's Report : Optical System -2 Broken Fibres, Angulation- No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check- No Fault Found *SN W800746* *Mfd 2008* 1 StatusUnsold View details 60 Olympus GIF XP260AN Video Gastroscope in Carry Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Angulation - Not Reaching Speching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Leak Check- Leak on Down Angulation, *Mfd 2009* *SN 2917238* Comments- Ex Vet Use* 1 Winning BidN/AStatusSold View details 61 Pentax ECY-1570K 2.0 Video Cystoscope - Engineer's Report : Optical System -No Fault Found, Light Transmission -No Fault Found , Angulation -No Fault Found , Insertion Tube - Damage Beneath Grip, Leak Check- No Fault Found, Accessories 1 x Waterproof Cap *GL* 1 Winning BidN/AStatusSold View details 62 Tekno 700-063 30 Degree Rigid Scope with 4 x Various Sheaths in Case - Engineer's Report : Optical System - Poor, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 63 Olympus Job Lot Including 1 x Olympus VISERA OTV-S7 Camera Control Unit, 1 x Olympus VISERA CLV-S40 Light Source Unit and 1 x Olympus OTV-S7H Camera Head (All Power Up, Monitor Not Included - See Photos for Camera Condition) 1 Winning BidN/AStatusSold View details 64 Olympus OTV-S7 Camera Head (See Photos for Camera Condition - Monitor Not Included) 1 Winning BidN/AStatusSold View details 65 Karl Storz Job Lot Including 1 x Karl Storz Endoskope 201315 20 Xenon nova 175 Light Source, 1 x Karl Storz Endoskope 222000 20 SCB image 1 hub Camera Unit and 1 x Karl Storz Image 1 P3 REF 22220131 NTSC Camera Head (All Power Up, Monitor Not Included - See Photos for Camera Condition) 1 Winning BidN/AStatusSold View details 66 1 x Olympus Digital 3CCD OTV-SX2 Camera with 1 x Olympus AR-LX083 Coupler and 1 x Olympus AR-SX12E Coupler in Carry Case *SN 1202040* 1 Winning BidN/AStatusSold View details 67 Olympus EVIS MAJ-1911 Pigtail Connector *SN 7706010* 1 Winning BidN/AStatusSold View details 68 Stryker 1188 HD REF 1188-210-105 Camera with Tray 1 Winning BidN/AStatusSold View details 69 Stryker 1188 HD REF 1188-210-105 Camera Head with Tray 1 Winning BidN/AStatusSold View details 70 Stryker 1488 HD REF 1488-210-105 Camera Head with Tray 1 Winning BidN/AStatusSold View details 71 Olympus MH-237 Pigtail Connector 1 Winning BidN/AStatusSold View details 72 Olympus CLH-250 Light Source with 1 x Pentax BS-LC1 Fiber Optic Light Cable (Powers Up, No Bulb) 1 StatusUnsold View details 73 Stryker 40L High Flow Insufflator Unit (Powers Up) 1 Winning BidN/AStatusSold View details 74 Olympus UHI-3 Insufflator Unit (Powers Up) 1 Winning BidN/AStatusSold View details 75 Olympus HPU-20 Heat Probe Unit with 1 x Olympus MAJ-528 Foot Switch (Powers Up with Fault-See Photo) 1 StatusUnsold View details 76 Olympus Job Lot Including 1 x Olympus A3092 Light Source Cable, 1 x Olympus AR-T2 Coupler, 1 x Olympus MAJ-524 Miniature Portable Light Source, and Various Light Source Cable Attachments 1 Winning BidN/AStatusSold View details 77 Olympus Evis Lucera Elite MAJ-1911 Pigtail Connector 1 Winning BidN/AStatusSold View details 78 Stryker 1188 HD REF 1188-210-105 Camera Head with Tray 1 Winning BidN/AStatusSold View details 79 Stryker X8000 Light Source Unit (Powers Up with Missing Dial-See Photo) 1 Winning BidN/AStatusSold View details 80 Stryker 40L High Flow Insufflator Unit (Powers Up) 1 Winning BidN/AStatusSold View details 81 Pentax FNL-10RP3 Rhinolaryngoscope- Engineer's Report : Optical System - 1 Broken Fiber, Angulation - Bending Section Partially Seized, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *SN G117478* 1 Winning BidN/AStatusSold View details 82 ACMI M3-30A Rigid Scope - Engineer's Report: Optical System -No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - 20% Light Loss, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 83 Linvatec QL4300 Autoclav 30 Degree Arthroscope - Engineer's Report : Optical System -No Fault Found, Angulation -No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, 1 Winning BidN/AStatusSold View details 84 Stryker 502-539-030 5mm 30 Degree Laparoscope - Engineer's Report : Optical System - Shattered, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 85 Karl Storz 27005 BA Cystoscope- Engineer's Report : Optical System - Stained , Angulation - , Insertion Tube - Ok, Light Transmission - 20% Loss *SN 978283* 1 Winning BidN/AStatusSold View details 86 Stryker 502-539-030 5mm 30 Degree Laparoscope - Engineer's Report : Optical System -Obscured, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 87 Karl Storz 27005BA Cystoscope- Engineer's Report : Optical System - Cloudy, Angulation - , Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 88 Olympus A22002A Cystoscope- Engineer's Report : Optical System - Cloudy, Angulation - , Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 89 Karl Storz 27005 BA Cystoscope- Engineer's Report : Optical System - Cloudy , Angulation - , Insertion Tube - Ok, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 90 Olympus A22002A 30 Degree Cystoscope- Engineer's Report : Optical System - Ok, Insertion Tube - Ok, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 91 Olympus A3764A 0 Degree Cystoscope - Engineer's Report : Optical System - Cloudy, Insertion Tube - No Fault Found, Light Transmission -No Fault Found 1 Winning BidN/AStatusSold View details 92 R Wolf 8972.433 25 Degree Panoview Ureteroscope - Engineer's Report : Optical System - Cloudy, Insertion Tube - No Fault Found, Light Transmission -Excessive Light Loss 1 Winning BidN/AStatusSold View details 93 Karl Storz 1230 C 70 Degree Arthroscope in Tray - Engineer's Report : Optical System - Clipped Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 94 DP Medical TF-6 Flexible Endoscope in Carry Case - Engineer's Report : Optical System - Image Totally Obscured, Angulation - Seized , Insertion Tube - No Fault Found, Light Transmission -Excess Light Loss 1 StatusUnsold View details 95 Richard Wolf 8914.31 Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 96 Richard Wolf 26036AA Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 97 Richard Wolf 26036AA Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 98 Richard Wolf 26036AA Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 99 Vision Sense A134 Video Arthroscope with 1 x Vision Sense REF 560-6532 Light Guide Cable and Sheath in Metal Tray - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *W* 1 StatusUnsold View details 100 Karl Storz 11101 CM Video Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found 1 Winning BidN/AStatusSold View details Items per page 102550100 Previous|12|Next Previous 12 Next