May 2023 Endoscopy 05/05/2023 3:00 PM BST - 10/05/2023 3:29 PM BST View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 101-145 of 145. Previous|12|Next Image Lot # Item Title Time Left Your Bids 103 ACMI 30 Degree HM Rigid Scope - Engineer's Report : Optical System - Stained Image, Light Transmission - 20% Loss, Insertion Tube - No Fault Found 1 Winning BidN/AStatusSold View details 104 ACMI M3 30 Degree Rigid Scope - Engineer's Report : Optical System - No Fault Found, Light Transmission - 10% Loss, Insertion Tube - No Fault Found 1 Winning BidN/AStatusSold View details 105 ACMI M3 30 Degree Rigid Scope - Engineer's Report : Optical System - Obscured, Light Transmission - Burnt, Insertion Tube - No Fault Found 1 Winning BidN/AStatusSold View details 106 ACMI M3 30 Degree Rigid Scope - Engineer's Report : Optical System - Obscured, Light Transmission -No Fault Found, Insertion Tube - No Fault Found 1 Winning BidN/AStatusSold View details 107 ACMI M3 12 Degree Rigid Scope - Engineer's Report : Optical System - Very Dark, Light Transmission -No Fault Found, Insertion Tube - No Fault Found 1 Winning BidN/AStatusSold View details 108 Linvatec 7570A O Degree Rigid Scope - Engineer's Report : Optical System - Blurred Image, Light Transmission -No Fault Found, Insertion Tube - No Fault Found 1 Winning BidN/AStatusSold View details 109 Gyrus L6-0A O Degree Rigid Scope - Engineer's Report : Optical System - No Fault Found, Light Transmission -No Fault Found, Insertion Tube - No Fault Found 1 Winning BidN/AStatusSold View details 110 Olympus UHI-3 Insufflator Unit (Powers Up) 1 Winning BidN/AStatusSold View details 110A Olympus UHI-3 Insufflator Unit (Powers Up) 1 Winning BidN/AStatusSold View details 111 Karl Storz SCB unidrive GYN 207111 20 Endoscopy Console with 1 x Karl Storz Model 20012630 Foot Pedal (Powers Up with Blank Display-See Photo) 1 Winning BidN/AStatusSold View details 112 Stryker 40L High Flow Insufflator Unit (Powers Up) 1 Winning BidN/AStatusSold View details 113 Stryker 40L High Flow Insufflator Unit (Powers Up) 1 Winning BidN/AStatusSold View details 114 Stryker X8000 Light Source (Powers Up) 1 Winning BidN/AStatusSold View details 115 Stryker X8000 Light Source (Powers Up) 1 Winning BidN/AStatusSold View details 116 Olympus LUS-2 Ultrasonic Lithotriptor Unit (No Power) 1 Winning BidN/AStatusSold View details 117 Olympus MH-237 Pigtail Endoscopy Processor Cable 1 Winning BidN/AStatusSold View details 118 Olympus PCF 240 S Video Sigmoidoscope In Carry Case - Engineer's Report : Optical System - No Fault Found , Light Transmission - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Accessories 1 x Waterproof Cap *SN 2400164* *GL* 1 Winning BidN/AStatusSold View details 119 Olympus PCF 240 S Video Sigmoidoscope In Carry Case - Engineer's Report : Optical System - No Fault Found , Light Transmission - No Fault Found, Angulation - No Fault Found, Insertion Tube - Rubber Grip Split, Accessories 1 x Waterproof Cap *SN 2700274* *GL* 1 Winning BidN/AStatusSold View details 120 Olympus CF Q260DL Video Colonoscope In Carry Case - Engineer's Report : Optical System - No Fault Found , Light Transmission - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Accessories 1 x Waterproof Cap *SN 2011416* *GL* 1 Winning BidN/AStatusSold View details 121 Olympus CF Q260DL Video Colonoscope In Carry Case - Engineer's Report : Optical System - No Fault Found , Light Transmission - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Accessories 1 x Waterproof Cap *Mfd 2015* *SN 2512085* *GL* 1 Winning BidN/AStatusSold View details 122 Olympus BF Type P260F Bronchoscope in Carry Case - Engineer's Report : Optical System - 5 Broken Fibres and Fluid Stains , Light Transmission - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Leak Check- Leak on Down Angulation, Accessories 1 x Waterproof Cap *Mfd 2008* *SN 2800842* Comments- Ex Vet Use* 1 Winning BidN/AStatusSold View details 123 Olympus GIF XP260AN Video Gastroscope in Carry Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Angulation - Not Reaching Speching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Leak Check- Leak on Down Angulation, *Mfd 2009* *SN 2917238* Comments- Ex Vet Use* 1 StatusUnsold View details 124 Olympus GIF 2T240 Video Gastroscope in Carry Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Angulation - Bending Section Strained, Insertion Tube - No Fault Found, Leak Check- Leak on Down Angulation, *Mfd 2008* *SN 2841378* *Comments- Ex Vet Use* 1 Winning BidN/AStatusSold View details 125 Pentax FNL-10RBS Laryngoscope in Carry Case - Engineer's Report : Optical System - 2 Broken Fibre, Light Transmission - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Leak Check- Unable to Check, Other Comments Body in Dismantled Condition, See Photos *SN G111463* 1 Winning BidN/AStatusSold View details 126 Pentax FNL-10RBS Laryngoscope in Carry Case - Engineer's Report : Optical System - 2 Broken Fibre, Light Transmission - No Fault Found, Angulation -Excessive Play, Insertion Tube - Kinked, Bendy Rubber Missing-See Photos, Leak Check Unable to Check *SN G111784* 1 Winning BidN/AStatusSold View details 127 Pentax EG-3670URK 2.4 Ultrasound Video Endoscope - Engineer's Report : Optical System - Untested Due to No Processor, Angulation Badly Strained *GL* 1 Winning BidN/AStatusSold View details 128 Fujinon F0-120S Bronchoscope - Engineer's Report : Optical System - No Broken Fibres, Light Transmission - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks, Leak Check- No Fault Found *GL* 1 Winning BidN/AStatusSold View details 129 Olympus LF TP Laryngoscope - Engineer's Report : Optical System - 4 Broken Fibres, Light Transmission - No Fault Found, Angulation - Strained, Insertion Tube - Crush Marks, Leak Check- No Fault Found *GL* 1 Winning BidN/AStatusSold View details 130 Olympus LF GP Laryngoscope - Engineer's Report : Optical System - 6 Broken Fibres, Light Transmission - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks, Leak Check- No Fault Found *GL* 1 Winning BidN/AStatusSold View details 131 Olympus LF TP Laryngoscope - Engineer's Report : Optical System - No Broken Fibres, Light Transmission - No Fault Found, Angulation - Strained, Insertion Tube - No Fault Found, Leak Check- No Fault Found *GL* 1 Winning BidN/AStatusSold View details 132 Olympus HYF Type XP Hysteroscope - Engineer's Report : Optical System - Fluid Stain, Light Transmission - No Fault Found, Angulation - Strained, Insertion Tube - Crushed B Section, Leak Check- No Fault Found *GL* 1 Winning BidN/AStatusSold View details 133 Pentax ECY-1570K 2.0 Video Cystoscope - Engineer's Report : Optical System -No Fault Found, Light Transmission -No Fault Found , Angulation -No Fault Found , Insertion Tube - Damage Beneath Grip, Leak Check- No Fault Found, Accessories 1 x Waterproof Cap *GL* 1 StatusUnsold View details 134 Olympus LF DP Laryngoscope - Engineer's Report : Optical System - Excessive Broken Fibres, Light Transmission - No Fault Found, Angulation - Distorted, Insertion Tube - Severely Crushed, Leak Check- Leak from Tube, Channels- Restricted *SN 1001196* *GL* 1 Winning BidN/AStatusSold View details 135 Olympus CYF-2 Video Cystoscope - Engineer's Report : Optical System -25+ Broken Fibres and Fluid Stain, Light Transmission -No Fault Found , Distorted, Insertion Tube -Kinked and Strined, Leak Check- No Fault Found *SN 1000815* *GL* 1 Winning BidN/AStatusSold View details 136 Olympus CYF-2 Cystoscope - Engineer's Report : Optical System - Obscured by Fluid, Light Transmission -Ok, Insertion Tube - Badly Kinked, Angulation - Strained, Leak Check- Tube Leaking *GL* 1 Winning BidN/AStatusSold View details 137 Olympus HYF-Type 1T Fibre Optic Hysteroscope Engineer's Report : Optical System - No Broken Fibres, Light Transmission -No Broken Fibres, Insertion Tube - No Fault Found, Angulation - No Fault Found, Leak Check- No Fault Found* *SN 1101459* *GL* 1 Winning BidN/AStatusSold View details 138 Olympus LF DP Laryngoscope - Engineer's Report : Optical System - 1 Broken Fibre, Light Transmission -No Broken Fibres, Insertion Tube - No Fault Found, Angulation - No Fault Found, Leak Check- No Fault Found* *SN W400755* *GL* 1 Winning BidN/AStatusSold View details 139 Vision Sciences CST-4000 Cystoscope - Engineer's Report : Optical System - Excessive Broken Fibres, Light Transmission -No Fault Found, Insertion Tube - Badly Crushed, Angulation - No Fault Found, Leak Check- Unable to Check* *GL* 1 Winning BidN/AStatusSold View details 140 Olympus GIF-XQ30 Video Gastroscope - Engineer's Report : Optical System - Minor Dirt Particles, Light Transmission -No Fault Found, Insertion Tube - No Fault Found, Angulation - No Fault Found, Leak Check- Leak From Bio Channel* Comments- Missing Tag, See Photo *GL* 1 Winning BidN/AStatusSold View details 141 Olympus LF GP Laryngoscope - Engineer's Report : Optical System - 4 Broken Fibres, Light Transmission -No Fault Found, Insertion Tube - Badly Kinked, Angulation - No Fault Found, Leak Check- No Fault Found *GL* 1 Winning BidN/AStatusSold View details 142 Olympus MAF Type Mobile Airways Scope - Engineer's Report : Optical System - Unable to Check, Insertion Tube -Tube Damage Beneath Grip, Bad Kink, Light Transmission- Unable to Check, Angulation - No Fault Found, Leak Check- No Fault Found *GL* 1 Winning BidN/AStatusSold View details 143 Pentax ECY-1570K 2.0 Video Cystoscope - Engineer's Report : Optical System -Image Interference, Light Transmission -No Fault Found , Angulation -No Fault Found , Insertion Tube - No Fault Found, Leak Check- No Fault Found, Accessories 1 x Waterproof Cap *GL* 1 Winning BidN/AStatusSold View details 144 Pentax ECY-1570K 2.0 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Light Transmission -No Fault Found , Angulation -No Fault Found , Insertion Tube - Worn, Leak Check- No Fault Found, Accessories 1 x Waterproof Cap *GL* 1 Winning BidN/AStatusSold View details 145 Job Lot Including 1 x Karl Storz TC 200 image 1 S Connect Console (Powers Up) 1 x Karl Storz Model 20040240US Keyboard 1 Winning BidN/AStatusSold View details 146 Olympus MAJ-1215 Endoscopic Autoclavable Lithotripter Transducer Handpiece *SN 7710381* 1 Winning BidN/AStatusSold View details Items per page 102550100 Previous|12|Next Previous 12 Next