BRITISH MEDICAL AUCTIONS May 2023 Endoscopy (#672) 05/05/2023 3:00 PM BST - 10/05/2023 3:29 PM BST CLOSED Starts Ending 10/05/2023 1:04 PM BST Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 145. Previous|12|Next Lot 1 Karl Storz 11272VN Video Cystoscope with Leak Tester in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 2 Karl Storz 11101CM Video Pharyngoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - Unable to Check View details Winning BidN/A Lot 3 Karl Storz 11302BD2 Laryngoscope in Case - Engineer's Report : Optical System - 60 Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Worn Tube, Light Transmission - No Fault Found, Leak Check - Unable to Check Due to No Bending Section Rubber *RI* View details Winning BidN/A Lot 4 Karl Storz 11272VN Video Cystoscope with Leak Tester in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check Due to Incompatible Leak Tester View details Winning BidN/A Lot 5 Karl Storz 11272VN Video Cystoscope with Damaged Leak Tester in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked and Rucked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check View details Winning BidN/A Lot 6 Karl Storz 11278VSUA Video Urethroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Down Broken, Insertion Tube - Strained, Light Transmission - No Fault Found, Leak Check - Unable to Check View details Winning BidN/A Lot 7 Karl Storz 27005BA 30 Degree Rigid Scope - Engineer's Report : Optical System - No Image, Insertion Tube - Distorted, Light Transmission - 30% Loss View details Winning BidN/A Lot 8 Richard Wolf 8974.401 Cystoscope - Engineer's Report : Optical System - Very Poor Dark Image, Insertion Tube - Distorted, Light Transmission - No Fault Found View details StatusUnsold Lot 9 Karl Storz 27005FA Cystoscope - Engineer's Report : Optical System - Shattered Image, Insertion Tube - No Fault Found, Light Transmission - 100% Loss View details Winning BidN/A Lot 10 Gimmi GMS40A with Accessories in Case - Engineer's Report :Optical System - No Fault Found, Insertion Tube - Distorted, Light Transmission - Major Loss View details Winning BidN/A Lot 11 Olympus ENF-P3 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink, Light Transmission - No Fault Found, Leak Check - No Fault Found *2601645* View details Winning BidN/A Lot 12 Olympus GIF-1T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2730381* View details Winning BidN/A Lot 13 Olympus GIF-XP260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2323778* View details Winning BidN/A Lot 14 DP Medical TF6 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *RI* View details Winning BidN/A Lot 15 Pentax FNL-10RBS Pharyngoscope with 2 x Mini Light Sources and 1 x Light Source Cable in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115805* View details Winning BidN/A Lot 16 Pentax FNL-10RBS Pharyngoscope with 1 x Light Source Cable in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115838* View details Winning BidN/A Lot 17 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2512084* View details Winning BidN/A Lot 18 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2411972* View details Winning BidN/A Lot 19 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2311832* View details Winning BidN/A Lot 20 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2211630* View details Winning BidN/A Lot 21 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2633773* (RI) View details Winning BidN/A Lot 22 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Bending Section Rubber Split, Tube Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check *2860606* (RI) View details StatusUnsold Lot 23 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2040719* View details Winning BidN/A Lot 24 Olympus GIF-XP260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2023634* View details Winning BidN/A Lot 25 Olympus LF-TP Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Leak from Bending Section Rubber, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak from Bending Section Rubber *W900787* View details Winning BidN/A Lot 26 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2846401* View details Winning BidN/A Lot 27 Olympus LF-TP Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 0 Broken Fibers, Slight Stain Present, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1900707* View details Winning BidN/A Lot 28 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2330229* View details Winning BidN/A Lot 29 Olympus CYF-3 Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak from Tube *905508* View details Winning BidN/A Lot 30 Olympus GIF-2T200 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Worn Surface, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500778* View details Winning BidN/A Lot 31 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2235692* View details Winning BidN/A Lot 32 Olympus PCF-P240AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Multiple Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Insertion Tube Leaking *2300100* View details Winning BidN/A Lot 33 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2745480* View details Winning BidN/A Lot 34 Olympus GIF-XQ230 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Coating Peeling, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2502372* View details Winning BidN/A Lot 35 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Badly Strained, Not Reaching Specification, Insertion Tube - Minor Twist Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2011390* View details Winning BidN/A Lot 36 Olympus GIF-Q240Z Video Gastroscope in Case - Engineer's Report : Optical System - Intermittent Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2200174* View details Winning BidN/A Lot 37 Olympus GIF-XK240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300714* View details Winning BidN/A Lot 38 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - Head Functions Inoperative, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2330226* View details Winning BidN/A Lot 39 Olympus BF-10 Bronchoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300179* View details Winning BidN/A Lot 40 Stryker 502-539-010 Laparoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 41 Stryker 502-205-030 Laparoscope - Engineer's Report : Optical System - Dark Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details StatusUnsold Lot 42 Olympus A4674A Cystoscope with Sheath in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 43 Karl Storz 11278V Ureteroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Strained, Light Transmission - Unable to Check, Leak Check - Unable to Check View details Winning BidN/A Lot 44 Karl Storz 11272VN Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Rucked, Light Transmission - No Fault Found, Leak Check - Unable to Check View details Winning BidN/A Lot 45 Karl Storz 11272VN Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - Unable to Check View details Winning BidN/A Lot 46 Karl Storz 11272VN Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - Unable to Check View details Winning BidN/A Lot 47 Karl Storz 11272VN Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Rucked, Light Transmission - No Fault Found, Leak Check - Unable to Check View details Winning BidN/A Lot 48 Olympus BF-P180 Video Bronchoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Strained, Insertion Tube - Grip Split and Crush Marks Present, Light Transmission - No Fault Found, Channels - Catching, Leak Check - Leak at Body *2700887* View details Winning BidN/A Lot 49 Karl Storz 1230 70 Degree Arthroscope with Punch (Damaged) View details Winning BidN/A Lot 50 Pentax EB-1170K Video Bronchoscope - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - Severely Crushed, Light Transmission - Excess Light Loss *G120438* View details Winning BidN/A Lot 51 Olympus CF-P200S Video Sigmoidoscope - Engineer's Report : Optical System - Head Function Inoperative, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *2020902* View details Winning BidN/A Lot 52 Olympus CF-P20S Sigmoidoscope - Engineer's Report : Optical System - Over 80 Broken Fibers, Angulation - Strained, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2826227* View details Winning BidN/A Lot 53 Vision Sciences ENT-2000 Rhinolaryngoscope - Engineer's Report : Optical System - Fluid Contamination, Angulation - Broken, Insertion Tube - Stripped Covering, Light Transmission - Poor View details StatusUnsold Lot 54 Olympus MAF-GM Airways Scope - Engineer's Report : Optical System - Untested Due to No Battery, Angulation - No Fault Found, Insertion Tube - Crush Marks, Channels - Catching View details Winning BidN/A Lot 55 Olympus A5294A 0 Degree Laparoscope - Engineer's Report : Optical System - Blurred, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 56 Karl Storz 26046 BA Cystoscope with 2 x Sheaths in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - Indentation Present, Light Transmission - No Fault Found View details Winning BidN/A Lot 57 Karl Storz 0 Degree Rigid Scope with Light Guide Tube (100% Light Loss) in Case - Engineer's Report : Optical System - Poor Blurred Image, Insertion Tube - Indentation Present, Light Transmission - No Fault Found View details Winning BidN/A Lot 58 Karl Storz 26008 BA 30 Degree Rigid Scope with 5 x Various Sheaths - Engineer's Report : Optical System - Poor, Insertion Tube - No Fault Found, Light Transmission - 100% Loss View details Winning BidN/A Lot 59 Karl Storz 26120 BA 30 Degree Rigid Scope with 5 x Various Sheaths - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 62 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *13TA059* View details Winning BidN/A Lot 63 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120096* View details Winning BidN/A Lot 64 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120177* View details Winning BidN/A Lot 65 Pentax EC-3840LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *E02053* View details Winning BidN/A Lot 66 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120219* View details Winning BidN/A Lot 67 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120101* View details Winning BidN/A Lot 68 Olympus CF-200S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2410228* View details Winning BidN/A Lot 69 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120222* View details Winning BidN/A Lot 70 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120132* View details Winning BidN/A Lot 71 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120204.* View details Winning BidN/A Lot 72 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120133* View details Winning BidN/A Lot 73 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120093* View details Winning BidN/A Lot 74 Pentax FNL-10RBS Laryngoscope with Mini Light Source in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Unable to Check *G111811* View details Winning BidN/A Lot 75 Pentax FNL-10RBS Laryngoscope in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110608* View details Winning BidN/A Lot 76 Pentax FNL-10RBS Laryngoscope with Mini Light Source in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Leak Check - Unable to Check, Other Comments - Partially Dismantled *A110405* View details Winning BidN/A Lot 77 Olympus GF-UM2000 Ultrasound Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1210158* View details Winning BidN/A Lot 78 Visionsense 0 Degree Video Rigid Arthroscope with Light Guide Tube in Tray - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found (W) View details StatusUnsold Lot 79 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 0 x Broken Fibers, Dirt Marks on Optics, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111783* View details Winning BidN/A Lot 80 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 1 x Broken Fiber, 4 x Grey Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111753* View details StatusUnsold Lot 81 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 45 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111178* View details StatusUnsold Lot 82 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 2 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111836* View details Winning BidN/A Lot 83 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks and Indents Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400245* View details Winning BidN/A Lot 84 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500437* View details Winning BidN/A Lot 85 Olympus CYF-240A Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400333* View details Winning BidN/A Lot 86 Xion EF-N Pharyngoscope - Engineer's Report : Optical System - Fluid Stain, Angulation - Stained, Insertion Tube - Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 05725* View details StatusUnsold Lot 87 Olympus GFB Gastroscope Camera - Engineer's Report : Optical System - Fluid and Broken Fibres, Angulation - Seized, Insertion Tube - No Fault Found, Light Transmission - Light Bulb with Tip, Channels - No Fault Found, Leak Check - No Fault Found Comments- Historical Medical Antique *Mfd 1965* View details Winning BidN/A Lot 88 Olympus GIF-XQ20 Gastroscope-Engineer's Report : Optical System - Excessive Broken Fibres, Angulation - Ok, Insertion Tube - Badly Kinked, Light Transmission - Ok, Channels - Catch, Leak Check - No Fault Found, Comments- Model Badge Missing-See Photo *SN 2700975* *Mfd 1997* View details Winning BidN/A Lot 89 Olympus GIF-H260 Video Gastroscope in Carry Case - Engineer's Report : Optical System - Ok, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Accessories- 1 x Waterproof Cap *SN 2243973* View details Winning BidN/A Lot 90 Olympus GIF-H260 Video Gastroscope in Carry Case - Engineer's Report : Optical System -No Fault Found, Angulation -No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *SN 2846227* *Mfd 2008* View details Winning BidN/A Lot 91 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - Ok, Angulation - Strained and Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *SN 2710779* View details Winning BidN/A Lot 92 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - Ok, Angulation - Strained and Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *SN 2710776* View details Winning BidN/A Lot 93 Olympus ENF-T3 Pharyngoscope in Case - Engineer's Report : Optical System - Unable to Focus, Dirt in Eyepiece, Angulation - Strained, Insertion Tube - Twisted, Light Transmission - 50% Loss, Leak Check - Body Leaking *SN 1211498* View details Winning BidN/A Lot 94 Olympus GIF 1T240 Video Gastroscope in Carry Case - Engineer's Report : Optical System -No Fault Found, Angulation -No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *SN 2730390* View details Winning BidN/A Lot 95 Olympus ENF Type P4 Rhinolaryngoscope In Carry Case - Engineer's Report : Optical System -2 Broken Fibres, Angulation- No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check- No Fault Found *SN W800746* *Mfd 2008* View details StatusUnsold Lot 96 Olympus ENF Type P4 Rhinolaryngoscope In Carry Case - Engineer's Report : Optical System -1 Broken Fibre, Angulation- No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check- No Fault Found *SN 1125880* *Mfd 2011* View details Winning BidN/A Lot 97 Karl Storz 11102 CM Video Pharyngoscope in Carry Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable To Check *SN74658* View details Winning BidN/A Lot 98 Karl Storz 11102 CM Video Pharyngoscope in Carry Case - Engineer's Report : Optical System - Unable to Check, Light Transmission Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found *SN 66758* View details Winning BidN/A Lot 99 Karl Storz 11102 CM Video Pharyngoscope in Carry Case - Engineer's Report : Optical System - Unable to Check, Light Transmission Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found *SN 67061* View details Winning BidN/A Lot 100 Karl Storz 11102 CM Video Pharyngoscope in Carry Case - Engineer's Report : Optical System - Unable to Check, Light Transmission Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found *SN 68263* View details Winning BidN/A Lot 101 Karl Storz Image HD 1 REF H3-Z TH100 SPIES Camera Head View details Winning BidN/A Lot 102 ACMI M3-30A Gold Rigid Scope - Engineer's Report : Optical System - No Fault Found , Light Transmission - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Items per page 102550100 Previous|12|Next Previous 12 Next Previous 12 Next