BRITISH MEDICAL AUCTIONS April 2023 Endoscopy (#655) 04/04/2023 1:00 PM BST - 14/04/2023 5:10 PM BST CLOSED Starts Ending 14/04/2023 1:00 PM BST Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 121. Previous|12|Next Lot 1 Olympus BF-F260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2651203* View details Winning BidN/A Lot 2 Olympus GIF-100 Video Gastroscope with Leak Tester, Water Bottle and Waterproof Cap in Case - Engineer's Report : Optical System - No Fault Found, Angulation- No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Fond *2013081* View details Winning BidN/A Lot 3 Olympus GIF-100 3 Meter Conversion Equine Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation- No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Fond *2113036* View details Winning BidN/A Lot 4 Fujinon EC-530WL3 Video Colonoscope in Case - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Kinks in Light Guide Tube *643D001* View details Winning BidN/A Lot 5 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Kinks in Light Guide Tube *2857629* View details Winning BidN/A Lot 6 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Tube Leak, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak from Tube *2734139* View details Winning BidN/A Lot 7 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Wrinkles Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300783* View details Winning BidN/A Lot 8 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300785* View details Winning BidN/A Lot 9 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710833* View details Winning BidN/A Lot 10 Olympus GIF-H260 Video Gastroscope in Case - - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2040709* View details Winning BidN/A Lot 11 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2846405* View details Winning BidN/A Lot 12 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2846406* View details Winning BidN/A Lot 13 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Leaking, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Bending Section Rubber Leaking *2040708* View details Winning BidN/A Lot 14 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900471* View details Winning BidN/A Lot 15 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2200705* View details Winning BidN/A Lot 16 Fujinon EY-470S/B Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *13TA059* View details StatusUnsold Lot 17 Pentax FNL-10RP3 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Leak Check - No Fault Found *116821* View details Winning BidN/A Lot 18 Pentax FNL-10RP3 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Leak Check - No Fault Found *116839* View details Winning BidN/A Lot 19 Pentax FNL-10RP3 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Leak Check - No Fault Found *118714* View details Winning BidN/A Lot 20 Olympus GIF-XQ260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Tube Leak, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2934656* View details Winning BidN/A Lot 21 Thackery 30 Degree Rigid Arthroscope with Trocar - Engineer's Report - Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Major Light Loss View details Winning BidN/A Lot 22 Olympus A22001A Rigid Cystoscope - Engineer's Report : Optical System - No Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 23 Buck 30 Degree Rigid Cystoscope - Engineer's Report : Optical System - No Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 24 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2140721* View details Winning BidN/A Lot 25 Olympus PCF-Q260AL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2010552* View details Winning BidN/A Lot 26 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710835* View details Winning BidN/A Lot 27 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2000475* View details Winning BidN/A Lot 28 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2947706* View details Winning BidN/A Lot 29 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710831* View details Winning BidN/A Lot 30 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800142* View details Winning BidN/A Lot 31 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710818* View details Winning BidN/A Lot 32 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2947935* View details Winning BidN/A Lot 33 Olympus BF-1T260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2713209* View details Winning BidN/A Lot 34 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Tube Wrinkles, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2200703* View details Winning BidN/A Lot 35 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Tube Wrinkles, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300786* View details Winning BidN/A Lot 36 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2947936* View details Winning BidN/A Lot 37 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120205* View details Winning BidN/A Lot 38 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120096* View details StatusUnsold Lot 39 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120177* View details StatusUnsold Lot 40 Pentax EC-3840LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *E02053* View details StatusUnsold Lot 41 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120219* View details StatusUnsold Lot 42 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120101* View details StatusUnsold Lot 43 Olympus CF-200S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2410228* View details StatusUnsold Lot 44 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120222* View details StatusUnsold Lot 45 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120132* View details StatusUnsold Lot 46 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120204.* View details StatusUnsold Lot 47 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120133* View details StatusUnsold Lot 48 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120093* View details StatusUnsold Lot 49 Pentax FNL-10RBS Laryngoscope in Case - Engineer's Report : Optical System - 0 x Broken Fibers, No Mask, Angulation - Controls Missing, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - Unable to Check, Other Comments - Partially Dismantled *A110575* View details Winning BidN/A Lot 50 Olympus BF-1T260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2801115* View details Winning BidN/A Lot 51 Olympus BF-1T260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2801113* View details Winning BidN/A Lot 52 Pentax FNL-10RBS Laryngoscope with Mini Light Source in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Unable to Check *G111811* View details StatusUnsold Lot 53 Pentax FNL-10RBS Laryngoscope in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110608* View details StatusUnsold Lot 54 Pentax FNL-10RBS Laryngoscope with Mini Light Source in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Leak Check - Unable to Check, Other Comments - Partially Dismantled *A110405* View details StatusUnsold Lot 55 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120120* View details Winning BidN/A Lot 56 Pentax EC-3885LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120134* View details Winning BidN/A Lot 57 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930049* View details Winning BidN/A Lot 58 Olympus SIF-Q240 Video Enteroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710117* View details Winning BidN/A Lot 59 Olympus GIF-XP240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930106* View details Winning BidN/A Lot 60 Olympus GF-UC240P Ultrasound Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *1200025* View details Winning BidN/A Lot 61 Olympus GF-UC240P Ultrasound Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *1600082* View details Winning BidN/A Lot 62 Karl Storz 27002L Rigid Ureteroscope in Tray - Engineer's Report : Optical System - Orange Mark on Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 63 Karl Storz 260033A Rigid Laparoscope in Tray - Engineer's Report : Optical System - Cloudy / Misty, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 64 Olympus A70941A 30 Degree Rigid Arthroscope in Tray - Engineer's Report : Optical System - Poor Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 65 Richard Wolf 8934.441 Rigid Laparoscope in Tray - Engineer's Report : Optical System - Yellow, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 66 Karl Storz 27005A 0 Degree Rigid Cystoscope in Tray - Engineer's Report : Optical System - Chip on Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 67 Olympus A22005A 30 Degree Rigid Cystoscope in Tray - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 68 Olympus WA02943A Rigid Ureteroscope in Tray - Engineer's Report : Optical System - No Fault Found, Insertion Tube - Strained, Light Transmission - Scorched View details Winning BidN/A Lot 69 Olympus GF-UM2000 Ultrasound Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1210158* View details StatusUnsold Lot 70 Visionsense 0 Degree Video Rigid Arthroscope with Light Guide Tube in Tray - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found (W) View details StatusUnsold Lot 71 Arthrex AR3030 30 Degree Rigid Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 72 Olympus A2035A Rigid Cystoscope - Engineer's Report : Optical System - Dark and Obscured, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 73 Olympus A1932A Rigid Cystoscope - Engineer's Report : Optical System - Obscured, Insertion Tube - No Fault Found, Light Transmission - 10% Loss View details Winning BidN/A Lot 74 Atlantech 309WA Rigid Arthroscope - Engineer's Report : Optical System - Grey Patch on Image, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 75 Olympus A22005A Rigid Cystoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 76 Olympus BF-1T260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault *2302406* View details Winning BidN/A Lot 77 Olympus BF-1T260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault *2202283* View details Winning BidN/A Lot 78 Olympus BF-1T260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault *2202288* View details Winning BidN/A Lot 79 Pentax EC-3885LK Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120138* View details Winning BidN/A Lot 80 Pentax EC-3885LK Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120131* View details Winning BidN/A Lot 81 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 0 x Broken Fibers, Dirt Marks on Optics, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111783* View details StatusUnsold Lot 82 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111832* View details Winning BidN/A Lot 83 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111842* View details Winning BidN/A Lot 84 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111843* View details Winning BidN/A Lot 85 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 1 x Broken Fiber, 4 x Grey Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111753* View details StatusUnsold Lot 86 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111821* View details Winning BidN/A Lot 87 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 45 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111178* View details StatusUnsold Lot 88 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111801* View details Winning BidN/A Lot 89 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111831* View details Winning BidN/A Lot 90 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 2 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111836* View details StatusUnsold Lot 91 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111808* View details Winning BidN/A Lot 92 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 2 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111826* View details Winning BidN/A Lot 93 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111823* View details Winning BidN/A Lot 94 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111818* View details Winning BidN/A Lot 95 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111800* View details Winning BidN/A Lot 96 Pentax FNL-10RBS Laryngoscope with Mini Light Source - Engineer's Report : Optical System - 0 x Broken Fibers, Slight Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111824* View details Winning BidN/A Lot 97 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks and Indents Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400245* View details StatusUnsold Lot 98 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500437* View details StatusUnsold Lot 99 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600424* View details Winning BidN/A Lot 100 Olympus CYF-240A Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400333* View details StatusUnsold Items per page 102550100 Previous|12|Next Previous 12 Next Previous 12 Next