March 2023 Endoscopy 10/03/2023 3:00 PM GMT - 22/03/2023 4:00 PM GMT View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 172. Previous|12|Next Image Lot # Item Title Time Left Your Bids 1 Olympus PCF-Q260AL Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Play, Not Reaching Specification, To Be Adjusted, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2310683* 1 Winning BidN/AStatusSold View details 2 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2343311* 1 Winning BidN/AStatusSold View details 3 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2243302* 1 Winning BidN/AStatusSold View details 4 Olympus A2941A 7 Degree Rigid Endoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 5 Olympus WA29040A Rigid Ureteroscope in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - Distorted, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 6 Richard Wolf 4450-501 Rigid Endoscope - Engineer's Report : Optical System - Clipped Image, Insertion Tube - No Fault Found, Light Transmission - 10% Loss 1 Winning BidN/AStatusSold View details 7 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115984* 1 Winning BidN/AStatusSold View details 8 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 0 Broken Fibers, Rough Edge on Mask, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115985* 1 Winning BidN/AStatusSold View details 9 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110626* 1 Winning BidN/AStatusSold View details 10 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Twist Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *G114351* 1 Winning BidN/AStatusSold View details 11 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 2 Broken Fibers and Stain on Image, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115005* 1 Winning BidN/AStatusSold View details 12 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - Heavy Fluid Stain, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - Major Light Loss, Leak Check - No Fault Found *A110622* 1 Winning BidN/AStatusSold View details 13 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115971* 1 Winning BidN/AStatusSold View details 14 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kink Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115216* 1 Winning BidN/AStatusSold View details 15 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks and Indents Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400245* 1 StatusUnsold View details 16 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2622899* 1 Winning BidN/AStatusSold View details 17 Unknown Manufacturer 30 Degree Rigid Laparoscope - Engineer's Report : Optical System - Cloudy Vision - Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Other Comments - All I.D. Markings Worn Away 1 Winning BidN/AStatusSold View details 18 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500437* 1 StatusUnsold View details 19 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush and Kink Near Grip, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110571* 1 Winning BidN/AStatusSold View details 20 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 1 Broken Fiber and Stain on Edge, Angulation - No Fault Found, Insertion Tube - Rubber Grip Cone Adrift, Light Transmission - No Fault Found, Leak Check - Leak at Body Area *G114418* 1 Winning BidN/AStatusSold View details 21 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Severe Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115228* 1 Winning BidN/AStatusSold View details 22 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600424* 1 StatusUnsold View details 23 Olympus CYF-240A Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400333* 1 StatusUnsold View details 24 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - Head Functions Inoperable, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2958033* 1 Winning BidN/AStatusSold View details 25 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Down Angulation Flexi Broken, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2622886* 1 Winning BidN/AStatusSold View details 26 Olympus Evis Lucera MAJ-1154 Pigtail Connector 1 Winning BidN/AStatusSold View details 27 Olympus Evis Lucera MAJ-1154 Pigtail Connector 1 Winning BidN/AStatusSold View details 28 Olympus WA23080A Leak Tester with Fujinon Fitting 1 Winning BidN/AStatusSold View details 29 Olympus WA23080A Leak Tester with Karl Storz Fitting 1 Winning BidN/AStatusSold View details 30 Olympus WA23080A Leak Tester with Karl Storz Fitting 1 Winning BidN/AStatusSold View details 31 Olympus WA23080A Leak Tester with Karl Storz Fitting 1 Winning BidN/AStatusSold View details 32 Olympus WA23080A Leak Tester with Olympus Fitting 1 Winning BidN/AStatusSold View details 33 Olympus WA23080A Leak Tester with Olympus Fitting 1 Winning BidN/AStatusSold View details 34 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W800271* 1 Winning BidN/AStatusSold View details 35 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W900535* 1 Winning BidN/AStatusSold View details 36 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W900481* 1 Winning BidN/AStatusSold View details 37 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2734629* 1 Winning BidN/AStatusSold View details 38 Olympus CF-230L Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Worn at Proximal End, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500398* 1 Winning BidN/AStatusSold View details 39 Karl Storz 10331B Rigid Endoscope - Engineer's Report : Optical System - Approx. 8 Broken Fibers and Stain Present, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 StatusUnsold View details 40 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W900536* 1 Winning BidN/AStatusSold View details 41 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W040728* 1 Winning BidN/AStatusSold View details 42 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W900482* 1 Winning BidN/AStatusSold View details 43 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W900522* 1 Winning BidN/AStatusSold View details 44 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2723586* 1 Winning BidN/AStatusSold View details 45 Pentax EC-3490FK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120176* 1 Winning BidN/AStatusSold View details 46 Pentax EC-3840LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *E02054* 1 Winning BidN/AStatusSold View details 47 Almikro Rigid Endoscope in Box - Engineer's Report : Optical System - Stained, Insertion Tube - No Fault Found, Light Transmission - 20% Loss *02641* 1 Winning BidN/AStatusSold View details 48 Karl Storz 10331 B1 0 Degree Rigid Endoscope with Mini Light Source in Case - Engineer's Report - Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *1135528* 1 Winning BidN/AStatusSold View details 49 Olympus A50020A 0 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 50 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 51 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 52 Olympus A50020A 0 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 53 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 54 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 55 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 56 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Excessive Leak from Bending Section *W141168* 1 Winning BidN/AStatusSold View details 57 Olympus BF-1T180 Video Bronchoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Worn, Light Transmission - No Fault Found, Leak Check - Leak from Insertion Tube *2802258* 1 Winning BidN/AStatusSold View details 58 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Leak Check - Leak From Body, Case Cover Loose *W801010* 1 Winning BidN/AStatusSold View details 59 Olympus CYF-5 Cystoscope with Light Guide Tube - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W147582* 1 Winning BidN/AStatusSold View details 60 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *1301317* 1 Winning BidN/AStatusSold View details 61 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 12 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked and Crush Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *W800489* 1 Winning BidN/AStatusSold View details 62 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Crush Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *1301326* 1 Winning BidN/AStatusSold View details 63 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks, Light Transmission - No Fault Found, Leak Check - Minor Leak Present *1301327* 1 Winning BidN/AStatusSold View details 64 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kink Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *W700593* 1 Winning BidN/AStatusSold View details 65 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Crush Marks and Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W600488* 1 Winning BidN/AStatusSold View details 66 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 10 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *1301322* 1 Winning BidN/AStatusSold View details 67 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W600428* 1 Winning BidN/AStatusSold View details 68 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 12 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Leak Check - No Fault Found *2503587* 1 Winning BidN/AStatusSold View details 69 Vision Sciences TNE-5000 Laryngoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Channels - Unable to Check, Leak Check - No Fault Found *TE0143P* (H) 1 Winning BidN/AStatusSold View details 70 Olympus CYF-240A Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700576* 1 StatusUnsold View details 71 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710829* 1 Winning BidN/AStatusSold View details 72 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2911158* 1 Winning BidN/AStatusSold View details 73 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2610446* 1 Winning BidN/AStatusSold View details 74 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2911157* 1 Winning BidN/AStatusSold View details 75 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2510245* 1 Winning BidN/AStatusSold View details 76 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710675* 1 Winning BidN/AStatusSold View details 77 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 60+ Broken Fibers, Angulation - Strained, Insertion Tube - Strained, Light Transmission - No Fault Found, Leak Check - Leaking From Taped Up Light Guide Tube *W405278* 1 StatusUnsold View details 78 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 35 Broken Fibers, Angulation - Strained, Insertion Tube - Strained, Light Transmission - No Fault Found, Leak Check - No Fault Found *W405276* 1 StatusUnsold View details 79 Olympus CYF-240A Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700568* 1 Winning BidN/AStatusSold View details 80 Pentax FNL-10RBS Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinks and Crush Mark Present, Light Transmission - No Fault Found *G111816* 1 Winning BidN/AStatusSold View details 81 Olympus HYF-XP Hysteroscope in Case - Engineer's Report - Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crushed *W501509* 1 Winning BidN/AStatusSold View details 82 Henke-Sass, Wolf 233229 0 Degree Laparoscope - Engineer's Report : Optical System - Lens Damage, Insertion Tube - No Fault Found, Light Transmission - Major Loss 1 StatusUnsold View details 83 Dyonics KG14957 0 Degree Video Scope - Engineer's Report : Optical System - Unable To Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 StatusUnsold View details 84 Olympus A5294A 0 Degree Scope - Engineer's Report : Optical System - Unable To Check - Eyepiece Missing, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 StatusUnsold View details 85 Dyonics 3628 70 Degree Video Arthroscope - Engineer's Report : Optical System - Unable To Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 StatusUnsold View details 86 Dyonics 3628 70 Degree Video Arthroscope - Engineer's Report : Optical System - Unable To Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 StatusUnsold View details 87 Xion EF-N Pharyngoscope - Engineer's Report : Optical System - Fluid Stain, Angulation - Stained, Insertion Tube - Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 05725* 1 StatusUnsold View details 88 Zimmer 3953-62 30 Degree Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - 10% Light Loss 1 Winning BidN/AStatusSold View details 89 Acmi Microlens G68 0 Degree Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Minor Light Loss 15% 1 Winning BidN/AStatusSold View details 90 Dyonics 720 9401 70 Degree Video Arthroscope - Engineer's Report : Optical System - Unable To Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 StatusUnsold View details 91 Balholzer 10-0496-00 20 Degree Rigid Scope - Engineer's Report : Optical System - Poor, Insertion Tube - No Fault Found, Light Transmission - Poor 1 Winning BidN/AStatusSold View details 92 Karl Storz 28022A 0 Degree Angled Rigid Scope - Engineer's Report : Optical System - Clipped, Insertion Tube - No Fault Found, Light Transmission - 20% Loss 1 StatusUnsold View details 93 R.Wolf 884080 Dual Eyepiece Rigid Scope in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 94 Olympus A1933A 70 Degree Rigid Scope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - 10% Loss 1 Winning BidN/AStatusSold View details 95 Hologic MyoSure Tray Including MyoSure 40-200 0 Degree Rigid Scope with Cannula - Engineer's Report : Optical System - Poor, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 StatusUnsold View details 96 Olympus GFB Gastroscope Camera - Engineer's Report : Optical System - Fluid and Broken Fibres, Angulation - Seized, Insertion Tube - No Fault Found, Light Transmission - Light Bulb with Tip, Channels - No Fault Found, Leak Check - No Fault Found Comments- Historical Medical Antique *Mfd 1965* 1 StatusUnsold View details 97 Olympus GIF-XQ20 Gastroscope-Engineer's Report : Optical System - Excessive Broken Fibres, Angulation - Ok, Insertion Tube - Badly Kinked, Light Transmission - Ok, Channels - Catch, Leak Check - No Fault Found, Comments- Model Badge Missing-See Photo *SN 2700975* *Mfd 1997* 1 StatusUnsold View details 98 Olympus CHF-CB30L Choledocoscope in Case - Engineer's Report : Optical System - 15 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Channels - Restricted, Leak Check - No Fault Found *W800925* 1 Winning BidN/AStatusSold View details 99 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 8 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book 1 StatusUnsold View details 100 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 7 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book 1 StatusUnsold View details Items per page 102550100 Previous|12|Next Previous 12 Next