BRITISH MEDICAL AUCTIONS March 2023 Endoscopy (#639) 10/03/2023 3:00 PM GMT - 22/03/2023 4:00 PM GMT CLOSED Starts Ending 22/03/2023 1:00 PM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 172. Previous|12|Next Lot 1 Olympus PCF-Q260AL Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Play, Not Reaching Specification, To Be Adjusted, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2310683* View details Winning BidN/A Lot 2 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2343311* View details Winning BidN/A Lot 3 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2243302* View details Winning BidN/A Lot 4 Olympus A2941A 7 Degree Rigid Endoscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 5 Olympus WA29040A Rigid Ureteroscope in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - Distorted, Light Transmission - No Fault Found View details Winning BidN/A Lot 6 Richard Wolf 4450-501 Rigid Endoscope - Engineer's Report : Optical System - Clipped Image, Insertion Tube - No Fault Found, Light Transmission - 10% Loss View details Winning BidN/A Lot 7 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115984* View details Winning BidN/A Lot 8 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 0 Broken Fibers, Rough Edge on Mask, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115985* View details Winning BidN/A Lot 9 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110626* View details Winning BidN/A Lot 10 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Twist Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *G114351* View details Winning BidN/A Lot 11 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 2 Broken Fibers and Stain on Image, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115005* View details Winning BidN/A Lot 12 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - Heavy Fluid Stain, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - Major Light Loss, Leak Check - No Fault Found *A110622* View details Winning BidN/A Lot 13 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115971* View details Winning BidN/A Lot 14 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kink Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115216* View details Winning BidN/A Lot 15 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks and Indents Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400245* View details StatusUnsold Lot 16 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2622899* View details Winning BidN/A Lot 17 Unknown Manufacturer 30 Degree Rigid Laparoscope - Engineer's Report : Optical System - Cloudy Vision - Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Other Comments - All I.D. Markings Worn Away View details Winning BidN/A Lot 18 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report :Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500437* View details StatusUnsold Lot 19 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush and Kink Near Grip, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110571* View details Winning BidN/A Lot 20 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 1 Broken Fiber and Stain on Edge, Angulation - No Fault Found, Insertion Tube - Rubber Grip Cone Adrift, Light Transmission - No Fault Found, Leak Check - Leak at Body Area *G114418* View details Winning BidN/A Lot 21 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Severe Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *H115228* View details Winning BidN/A Lot 22 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600424* View details StatusUnsold Lot 23 Olympus CYF-240A Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400333* View details StatusUnsold Lot 24 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - Head Functions Inoperable, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2958033* View details Winning BidN/A Lot 25 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Down Angulation Flexi Broken, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2622886* View details Winning BidN/A Lot 26 Olympus Evis Lucera MAJ-1154 Pigtail Connector View details Winning BidN/A Lot 27 Olympus Evis Lucera MAJ-1154 Pigtail Connector View details Winning BidN/A Lot 28 Olympus WA23080A Leak Tester with Fujinon Fitting View details Winning BidN/A Lot 29 Olympus WA23080A Leak Tester with Karl Storz Fitting View details Winning BidN/A Lot 30 Olympus WA23080A Leak Tester with Karl Storz Fitting View details Winning BidN/A Lot 31 Olympus WA23080A Leak Tester with Karl Storz Fitting View details Winning BidN/A Lot 32 Olympus WA23080A Leak Tester with Olympus Fitting View details Winning BidN/A Lot 33 Olympus WA23080A Leak Tester with Olympus Fitting View details Winning BidN/A Lot 34 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W800271* View details Winning BidN/A Lot 35 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W900535* View details Winning BidN/A Lot 36 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W900481* View details Winning BidN/A Lot 37 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2734629* View details Winning BidN/A Lot 38 Olympus CF-230L Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Worn at Proximal End, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500398* View details Winning BidN/A Lot 39 Karl Storz 10331B Rigid Endoscope - Engineer's Report : Optical System - Approx. 8 Broken Fibers and Stain Present, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details StatusUnsold Lot 40 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W900536* View details Winning BidN/A Lot 41 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W040728* View details Winning BidN/A Lot 42 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W900482* View details Winning BidN/A Lot 43 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W900522* View details Winning BidN/A Lot 44 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2723586* View details Winning BidN/A Lot 45 Pentax EC-3490FK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A120176* View details Winning BidN/A Lot 46 Pentax EC-3840LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *E02054* View details Winning BidN/A Lot 47 Almikro Rigid Endoscope in Box - Engineer's Report : Optical System - Stained, Insertion Tube - No Fault Found, Light Transmission - 20% Loss *02641* View details Winning BidN/A Lot 48 Karl Storz 10331 B1 0 Degree Rigid Endoscope with Mini Light Source in Case - Engineer's Report - Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *1135528* View details Winning BidN/A Lot 49 Olympus A50020A 0 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 50 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 51 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 52 Olympus A50020A 0 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 53 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 54 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 55 Olympus WA50022B 30 Degree Video Laparoscope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 56 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Excessive Leak from Bending Section *W141168* View details Winning BidN/A Lot 57 Olympus BF-1T180 Video Bronchoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Worn, Light Transmission - No Fault Found, Leak Check - Leak from Insertion Tube *2802258* View details Winning BidN/A Lot 58 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Leak Check - Leak From Body, Case Cover Loose *W801010* View details Winning BidN/A Lot 59 Olympus CYF-5 Cystoscope with Light Guide Tube - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W147582* View details Winning BidN/A Lot 60 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *1301317* View details Winning BidN/A Lot 61 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 12 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked and Crush Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *W800489* View details Winning BidN/A Lot 62 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Crush Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *1301326* View details Winning BidN/A Lot 63 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks, Light Transmission - No Fault Found, Leak Check - Minor Leak Present *1301327* View details Winning BidN/A Lot 64 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kink Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *W700593* View details Winning BidN/A Lot 65 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Crush Marks and Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W600488* View details Winning BidN/A Lot 66 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 10 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *1301322* View details Winning BidN/A Lot 67 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W600428* View details Winning BidN/A Lot 68 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 12 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Leak Check - No Fault Found *2503587* View details Winning BidN/A Lot 69 Vision Sciences TNE-5000 Laryngoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Channels - Unable to Check, Leak Check - No Fault Found *TE0143P* (H) View details Winning BidN/A Lot 70 Olympus CYF-240A Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700576* View details StatusUnsold Lot 71 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710829* View details Winning BidN/A Lot 72 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2911158* View details Winning BidN/A Lot 73 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2610446* View details Winning BidN/A Lot 74 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2911157* View details Winning BidN/A Lot 75 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2510245* View details Winning BidN/A Lot 76 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710675* View details Winning BidN/A Lot 77 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 60+ Broken Fibers, Angulation - Strained, Insertion Tube - Strained, Light Transmission - No Fault Found, Leak Check - Leaking From Taped Up Light Guide Tube *W405278* View details StatusUnsold Lot 78 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 35 Broken Fibers, Angulation - Strained, Insertion Tube - Strained, Light Transmission - No Fault Found, Leak Check - No Fault Found *W405276* View details StatusUnsold Lot 79 Olympus CYF-240A Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700568* View details Winning BidN/A Lot 80 Pentax FNL-10RBS Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinks and Crush Mark Present, Light Transmission - No Fault Found *G111816* View details Winning BidN/A Lot 81 Olympus HYF-XP Hysteroscope in Case - Engineer's Report - Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crushed *W501509* View details Winning BidN/A Lot 82 Henke-Sass, Wolf 233229 0 Degree Laparoscope - Engineer's Report : Optical System - Lens Damage, Insertion Tube - No Fault Found, Light Transmission - Major Loss View details StatusUnsold Lot 83 Dyonics KG14957 0 Degree Video Scope - Engineer's Report : Optical System - Unable To Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details StatusUnsold Lot 84 Olympus A5294A 0 Degree Scope - Engineer's Report : Optical System - Unable To Check - Eyepiece Missing, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details StatusUnsold Lot 85 Dyonics 3628 70 Degree Video Arthroscope - Engineer's Report : Optical System - Unable To Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details StatusUnsold Lot 86 Dyonics 3628 70 Degree Video Arthroscope - Engineer's Report : Optical System - Unable To Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details StatusUnsold Lot 87 Xion EF-N Pharyngoscope - Engineer's Report : Optical System - Fluid Stain, Angulation - Stained, Insertion Tube - Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 05725* View details StatusUnsold Lot 88 Zimmer 3953-62 30 Degree Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - 10% Light Loss View details Winning BidN/A Lot 89 Acmi Microlens G68 0 Degree Arthroscope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Minor Light Loss 15% View details Winning BidN/A Lot 90 Dyonics 720 9401 70 Degree Video Arthroscope - Engineer's Report : Optical System - Unable To Check, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details StatusUnsold Lot 91 Balholzer 10-0496-00 20 Degree Rigid Scope - Engineer's Report : Optical System - Poor, Insertion Tube - No Fault Found, Light Transmission - Poor View details Winning BidN/A Lot 92 Karl Storz 28022A 0 Degree Angled Rigid Scope - Engineer's Report : Optical System - Clipped, Insertion Tube - No Fault Found, Light Transmission - 20% Loss View details StatusUnsold Lot 93 R.Wolf 884080 Dual Eyepiece Rigid Scope in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 94 Olympus A1933A 70 Degree Rigid Scope - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - 10% Loss View details Winning BidN/A Lot 95 Hologic MyoSure Tray Including MyoSure 40-200 0 Degree Rigid Scope with Cannula - Engineer's Report : Optical System - Poor, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details StatusUnsold Lot 96 Olympus GFB Gastroscope Camera - Engineer's Report : Optical System - Fluid and Broken Fibres, Angulation - Seized, Insertion Tube - No Fault Found, Light Transmission - Light Bulb with Tip, Channels - No Fault Found, Leak Check - No Fault Found Comments- Historical Medical Antique *Mfd 1965* View details StatusUnsold Lot 97 Olympus GIF-XQ20 Gastroscope-Engineer's Report : Optical System - Excessive Broken Fibres, Angulation - Ok, Insertion Tube - Badly Kinked, Light Transmission - Ok, Channels - Catch, Leak Check - No Fault Found, Comments- Model Badge Missing-See Photo *SN 2700975* *Mfd 1997* View details StatusUnsold Lot 98 Olympus CHF-CB30L Choledocoscope in Case - Engineer's Report : Optical System - 15 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Channels - Restricted, Leak Check - No Fault Found *W800925* View details Winning BidN/A Lot 99 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 8 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book View details StatusUnsold Lot 100 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 7 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book View details StatusUnsold Items per page 102550100 Previous|12|Next Previous 12 Next Previous 12 Next