January 2023 Endoscopy Equipment 16/01/2023 2:00 PM GMT - 25/01/2023 4:06 PM GMT Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViewsDefaultDefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Lot Number Filter By Categories Category match ANY of the aboveALL of the aboveANY of the aboveANY of the aboveALL of the above Featured Price Exclude closed lots View Search ▼ Items per page 102550100100 Results: Viewing items 1-94 of 94. Previous|1|Next Image Lot # Item Title Time Left Your Bids 1 Olympus GIF-Q240 Video Gastroscope in Case - Engineer's Report : Optical System - Head Unit Faulty, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found *2801385* 1 Winning BidN/AStatusSold View details 2 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2931616* 1 Winning BidN/AStatusSold View details 3 Olympus CF-240AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2110314* 1 Winning BidN/AStatusSold View details 4 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2134583* 1 Winning BidN/AStatusSold View details 5 Pentax ECY-1570K Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G120328* **RI** 1 Winning BidN/AStatusSold View details 7 Olympus GF-200 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2620546* 1 Winning BidN/AStatusSold View details 8 Olympus CF-10L Colonoscope in Case (Missing Badge) - Engineer's Report : Optical System - Obscured by Excessive Broken Fibers and Fluid Stain, Angulation - Not Reaching Specification, Insertion Tube - Severely Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *N/A* 1 Winning BidN/AStatusSold View details 9 Olympus CHF-CB30L Choledocoscope in Case - Engineer's Report : Optical System - 15 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Channels - Restricted, Leak Check - No Fault Found *W800925* 1 StatusUnsold View details 10 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *2700278* 1 Winning BidN/AStatusSold View details 11 Olympus LF-2 Laryngoscope in Case - Engineer's Report : Optical System - Image Totally Obscured, Angulation - Broken Wires, Insertion Tube - No Fault Found, Light Transmission - Nil *2813862* 1 StatusUnsold View details 12 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700518* 1 Winning BidN/AStatusSold View details 13 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indent, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800524* 1 Winning BidN/AStatusSold View details 14 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900638* 1 Winning BidN/AStatusSold View details 15 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900643* 1 Winning BidN/AStatusSold View details 16 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900639* 1 Winning BidN/AStatusSold View details 17 Olympus BF-240 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1240930* 1 Winning BidN/AStatusSold View details 18 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900641* 1 Winning BidN/AStatusSold View details 19 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900642* 1 Winning BidN/AStatusSold View details 22 Pentax FNL-10RP3 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Leaking, Light Transmission - No Fault Found, Leak Check - Bending Section Rubber Leaking *H141068* 1 Winning BidN/AStatusSold View details 23 Pentax FNL-10RP3 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Squash Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G116937* 1 Winning BidN/AStatusSold View details 24 Acutronic EF-I14 Laryngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found *10408* 1 StatusUnsold View details 25 Olympus CYF-4 Cystoscope - Engineer's Report : Optical System - 32 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Channels - Restricted, Leak Check - Light Guide Tube Leaking, Other Comments - Light Guide Tube has Tape Repair *W405278* 1 Winning BidN/AStatusSold View details 26 Olympus CYF-4 Cystoscope - Engineer's Report : Optical System - 22 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W405276* 1 Winning BidN/AStatusSold View details 27 Olympus BF Type 40 Bronchoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Wrinkles in Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700063* 1 Winning BidN/AStatusSold View details 28 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - 58 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - NO Fault Found *W704104* 1 Winning BidN/AStatusSold View details 29 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube -Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111816* 1 Winning BidN/AStatusSold View details 30 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111822* 1 Winning BidN/AStatusSold View details 31 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110404* 1 Winning BidN/AStatusSold View details 32 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - 1 x Minor Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111848* 1 Winning BidN/AStatusSold View details 33 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111819* 1 Winning BidN/AStatusSold View details 34 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110591* 1 Winning BidN/AStatusSold View details 35 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - Excessive Play, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110402* 1 Winning BidN/AStatusSold View details 36 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Minor Crush and Leak in Bending Section, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - Leak in Bending Section Rubber *G111820* 1 Winning BidN/AStatusSold View details 37 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111782* 1 Winning BidN/AStatusSold View details 38 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case Engineer's Report : Optical System - No Fault Found, Angulation - Crush in Bending Section, Insertion Tube - Badly Kinked, Bending Section Rubber Leaking, Light Transmission - No Fault Found, Leak Check - Bending Section Rubber Leaking *G111494* 1 Winning BidN/AStatusSold View details 39 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111479* 1 Winning BidN/AStatusSold View details 40 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111756* 1 Winning BidN/AStatusSold View details 41 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111812* 1 Winning BidN/AStatusSold View details 42 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111841* 1 Winning BidN/AStatusSold View details 43 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 1 x Minor Dirt Speck, Angulation - Crush in Bending Section, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111797* 1 Winning BidN/AStatusSold View details 44 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111764* 1 Winning BidN/AStatusSold View details 45 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111760* 1 Winning BidN/AStatusSold View details 46 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Excessive Play, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111840* 1 Winning BidN/AStatusSold View details 47 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111750* 1 Winning BidN/AStatusSold View details 48 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111839* 1 Winning BidN/AStatusSold View details 49 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - Crush in Bending Section, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111833* 1 Winning BidN/AStatusSold View details 50 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bad Kinks and Crush Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110601* 1 Winning BidN/AStatusSold View details 51 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111475* 1 Winning BidN/AStatusSold View details 52 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111491* 1 Winning BidN/AStatusSold View details 53 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111472* 1 Winning BidN/AStatusSold View details 54 Olympus LF-GP Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1212091* 1 Winning BidN/AStatusSold View details 55 Pentax EE-1580K Video Esophagoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120147* 1 Winning BidN/AStatusSold View details 56 Pentax EE-1580K Video Esophagoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - 1 x Minor Indentation, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120146* 1 StatusUnsold View details 57 Pentax EE-1580K Video Esophagoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120148* 1 StatusUnsold View details 58 Pentax EE-1580K Video Esophagoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120145* 1 Winning BidN/AStatusSold View details 62 Vision Sciences CST-5000 Video Cystoscope In Carry Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Rubber Grip Damaged, Light Transmission - No Fault Found, Leak Check - Unable to Check 1 Winning BidN/AStatusSold View details 63 Smith & Nephew DuraView OL-1 Rhinolaryngoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers and Fluid in Optics, Angulation - No Fault Found, Insertion Tube - Rubber Grip Missing, Light Transmission - No Fault Found *DV911002* 1 Winning BidN/AStatusSold View details 64 Olympus BF Type N20 Bronchoscope in Case - Engineer's Report : Optical System - 14 Broken Fibers, Angulation - Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - Major Loss, Leak Check - No Fault Found *1120876* 1 StatusUnsold View details 65 Olympus GIF Q10 Gastroscope in Case - Engineer's Report : Optical System - 6 Broken Fibers and Fluid Stain Present, Angulation - Bending Section Strained, Not Reaching Specification, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *C5002* 1 Winning BidN/AStatusSold View details 66 Karl Storz 11101RP2 Pharyngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 67 Karl Storz 11302 BDD2 Videoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 68 Karl Storz 11302 BDD2 Video Scope - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Plaster Sleeve Repair, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 69 Karl Storz 11302 BND1 Video Scope - Engineer's Report : Optical System - Blurred, Angulation - Strained, Insertion Tube - Kinked, Temporary Plaster Repair, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 70 Karl Storz 11302 BDD2 Video Scope - Engineer's Report : Optical System - Blurred, Angulation - No Fault Found, Insertion Tube - Minor Crush Marks, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 71 Olympus URF Type P5 Ureteroscope - Engineer's Report : Optical System - Fluid Stain Present, Angulation - Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *2243503* 1 Winning BidN/AStatusSold View details 72 Karl Storz 11302 BN1 Video Scope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Strained, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 73 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 74 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 75 Karl Storz 11272 VUA Video Cystoscope in Case - Engineer's Report : Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check 1 Winning BidN/AStatusSold View details 76 Karl Storz 11272 VNU Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check 1 Winning BidN/AStatusSold View details 80 Olympus CYF-VH Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Channels - Channel Leak *2827359* 1 Winning BidN/AStatusSold View details 82 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - Excessive Light Loss, Channels - No Fault Found, Leak Check - No Fault Found *2900328* 1 Winning BidN/AStatusSold View details 83 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - 20% Light Loss, Channels - No Fault Found, Leak Check - No Fault Found *W047373* 1 Winning BidN/AStatusSold View details 84 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - Dark Image, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800180* 1 Winning BidN/AStatusSold View details 85 Olympus CF-240L Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930203* 1 Winning BidN/AStatusSold View details 86 Olympus LF-2 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2014001** 1 Winning BidN/AStatusSold View details 87 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 8 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book 1 StatusUnsold View details 88 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 7 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book 1 StatusUnsold View details 89 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 8 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book 1 StatusUnsold View details 90 Job Lot Including 5 x Olympus MAJ-901 Water Containers and 1 x Olympus MAJ-902 Water Container 1 Winning BidN/AStatusSold View details 91 Olympus MAJ-1154 Pigtail Connector (Loose Casing) 1 Winning BidN/AStatusSold View details 92 Olympus MAJ-1911 Pigtail Connector 1 Winning BidN/AStatusSold View details 93 Job Lot Including 1 x Olympus MU-1 Maintenance Unit with Leakage Tester Cable (Powers Up), 2 x Soluscope OL-LF-TP Connexions, 4 x Pentax Waterproof Caps, 8 x Pentax Valves and 1 x CCS K10009118 Cable 1 Winning BidN/AStatusSold View details 94 Olympus ENF-XP Pharyngoscope in Case - Engineer's Report : Optical System - 14 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *2314149* 1 Winning BidN/AStatusSold View details 95 Pentax ECY-1570K Video Cystoscope in Carry Case - Engineer's Report : Optical System -No Fault Found, Angulation - No Fault Found, Insertion Tube -Worn, Light Transmission - Plug Separate from Light Guide Tube, Channels - No Fault Found, Leak Check -No Fault Plug Leak *SN G120280* *Mfd NA * 1 Winning BidN/AStatusSold View details 96 Karl Storz VN06030AEMV Video Scope with 2 x 0 Degree Optical Lenses and 2 x 90 Degree Optical Lenses in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - No Fault Found 1 StatusUnsold View details 97 Olympus CYF-3 Cystoscope - Engineer's Report : Optical System - 15% Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W501006* 1 StatusUnsold View details 98 Richard Wolf 7330.072 Intubation Scope - Engineer's Report : Optical System - Fluid Stain and Lens Separation, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check *142669* 1 StatusUnsold View details 99 Karl Storz VN06030AEMW Video Scope with 2 x 0 Degree Optical Lenses and 2 x 90 Degree Optical Lenses in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 100 Karl Storz VN06030AEMW Video Scope with 2 x 0 Degree Optical Lenses and 2 x 90 Degree Optical Lenses in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 101 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Image, Angulation - Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930475* 1 Winning BidN/AStatusSold View details 102 Karl Storz VN06030AEMW Video Scope with 2 x 0 Degree Optical Lenses and 2 x 90 Degree Optical Lenses in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - No Fault Found 1 Winning BidN/AStatusSold View details 103 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Catch in Bio Channel, Leak Check - No Fault Found *2600430* **6522-894** 1 Winning BidN/AStatusSold View details 104 Olympus ENF-GP Rhinolaryngoscope in Case - Engineer's Report : Optical System - 20 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kinks and Bad Crush Present, Light Transmission - No Fault Found, Leak Check - Excessive Body Leak *2612220* 1 StatusUnsold View details Items per page 102550100100 Previous|1|Next Previous 11 Next