BRITISH MEDICAL AUCTIONS January 2023 Endoscopy Equipment (#603) 16/01/2023 2:00 PM GMT - 25/01/2023 4:06 PM GMT CLOSED Starts Ending 25/01/2023 1:06 PM GMT View details Auction info BRITISH MEDICAL AUCTIONS Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViewsDefaultDefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Lot Number Filter By Categories Category match ANY of the aboveALL of the aboveANY of the aboveANY of the aboveALL of the above Featured Price Exclude closed lots View Search ▼ Results: Viewing items 1-94 of 94. Previous|1|Next Items per page 102550100100 Lot 1 Olympus GIF-Q240 Video Gastroscope in Case - Engineer's Report : Optical System - Head Unit Faulty, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found *2801385* View details Winning BidN/A Lot 2 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2931616* View details Winning BidN/A Lot 3 Olympus CF-240AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2110314* View details Winning BidN/A Lot 4 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2134583* View details Winning BidN/A Lot 5 Pentax ECY-1570K Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G120328* **RI** View details Winning BidN/A Lot 7 Olympus GF-200 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2620546* View details Winning BidN/A Lot 8 Olympus CF-10L Colonoscope in Case (Missing Badge) - Engineer's Report : Optical System - Obscured by Excessive Broken Fibers and Fluid Stain, Angulation - Not Reaching Specification, Insertion Tube - Severely Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *N/A* View details Winning BidN/A Lot 9 Olympus CHF-CB30L Choledocoscope in Case - Engineer's Report : Optical System - 15 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Channels - Restricted, Leak Check - No Fault Found *W800925* View details StatusUnsold Lot 10 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *2700278* View details Winning BidN/A Lot 11 Olympus LF-2 Laryngoscope in Case - Engineer's Report : Optical System - Image Totally Obscured, Angulation - Broken Wires, Insertion Tube - No Fault Found, Light Transmission - Nil *2813862* View details StatusUnsold Lot 12 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700518* View details Winning BidN/A Lot 13 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indent, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800524* View details Winning BidN/A Lot 14 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900638* View details Winning BidN/A Lot 15 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900643* View details Winning BidN/A Lot 16 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900639* View details Winning BidN/A Lot 17 Olympus BF-240 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1240930* View details Winning BidN/A Lot 18 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900641* View details Winning BidN/A Lot 19 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900642* View details Winning BidN/A Lot 22 Pentax FNL-10RP3 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Leaking, Light Transmission - No Fault Found, Leak Check - Bending Section Rubber Leaking *H141068* View details Winning BidN/A Lot 23 Pentax FNL-10RP3 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Squash Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G116937* View details Winning BidN/A Lot 24 Acutronic EF-I14 Laryngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found *10408* View details StatusUnsold Lot 25 Olympus CYF-4 Cystoscope - Engineer's Report : Optical System - 32 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Channels - Restricted, Leak Check - Light Guide Tube Leaking, Other Comments - Light Guide Tube has Tape Repair *W405278* View details Winning BidN/A Lot 26 Olympus CYF-4 Cystoscope - Engineer's Report : Optical System - 22 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W405276* View details Winning BidN/A Lot 27 Olympus BF Type 40 Bronchoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Wrinkles in Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700063* View details Winning BidN/A Lot 28 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - 58 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - NO Fault Found *W704104* View details Winning BidN/A Lot 29 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube -Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111816* View details Winning BidN/A Lot 30 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111822* View details Winning BidN/A Lot 31 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110404* View details Winning BidN/A Lot 32 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - 1 x Minor Crush Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111848* View details Winning BidN/A Lot 33 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111819* View details Winning BidN/A Lot 34 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Mark, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110591* View details Winning BidN/A Lot 35 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - Excessive Play, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110402* View details Winning BidN/A Lot 36 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Minor Crush and Leak in Bending Section, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - Leak in Bending Section Rubber *G111820* View details Winning BidN/A Lot 37 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111782* View details Winning BidN/A Lot 38 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case Engineer's Report : Optical System - No Fault Found, Angulation - Crush in Bending Section, Insertion Tube - Badly Kinked, Bending Section Rubber Leaking, Light Transmission - No Fault Found, Leak Check - Bending Section Rubber Leaking *G111494* View details Winning BidN/A Lot 39 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111479* View details Winning BidN/A Lot 40 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111756* View details Winning BidN/A Lot 41 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111812* View details Winning BidN/A Lot 42 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111841* View details Winning BidN/A Lot 43 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 1 x Minor Dirt Speck, Angulation - Crush in Bending Section, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111797* View details Winning BidN/A Lot 44 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111764* View details Winning BidN/A Lot 45 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111760* View details Winning BidN/A Lot 46 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Excessive Play, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111840* View details Winning BidN/A Lot 47 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111750* View details Winning BidN/A Lot 48 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111839* View details Winning BidN/A Lot 49 Pentax FNL-10RBS Nasolaryngoscope in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - Crush in Bending Section, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111833* View details Winning BidN/A Lot 50 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bad Kinks and Crush Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *A110601* View details Winning BidN/A Lot 51 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111475* View details Winning BidN/A Lot 52 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111491* View details Winning BidN/A Lot 53 Pentax FNL-10RBS Nasolaryngoscope with BS-LH2 Portable Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111472* View details Winning BidN/A Lot 54 Olympus LF-GP Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1212091* View details Winning BidN/A Lot 55 Pentax EE-1580K Video Esophagoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120147* View details Winning BidN/A Lot 56 Pentax EE-1580K Video Esophagoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - 1 x Minor Indentation, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120146* View details StatusUnsold Lot 57 Pentax EE-1580K Video Esophagoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120148* View details StatusUnsold Lot 58 Pentax EE-1580K Video Esophagoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120145* View details Winning BidN/A Lot 62 Vision Sciences CST-5000 Video Cystoscope In Carry Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Rubber Grip Damaged, Light Transmission - No Fault Found, Leak Check - Unable to Check View details Winning BidN/A Lot 63 Smith & Nephew DuraView OL-1 Rhinolaryngoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers and Fluid in Optics, Angulation - No Fault Found, Insertion Tube - Rubber Grip Missing, Light Transmission - No Fault Found *DV911002* View details Winning BidN/A Lot 64 Olympus BF Type N20 Bronchoscope in Case - Engineer's Report : Optical System - 14 Broken Fibers, Angulation - Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - Major Loss, Leak Check - No Fault Found *1120876* View details StatusUnsold Lot 65 Olympus GIF Q10 Gastroscope in Case - Engineer's Report : Optical System - 6 Broken Fibers and Fluid Stain Present, Angulation - Bending Section Strained, Not Reaching Specification, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *C5002* View details Winning BidN/A Lot 66 Karl Storz 11101RP2 Pharyngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Light Transmission - No Fault Found View details Winning BidN/A Lot 67 Karl Storz 11302 BDD2 Videoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 68 Karl Storz 11302 BDD2 Video Scope - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Plaster Sleeve Repair, Light Transmission - No Fault Found View details Winning BidN/A Lot 69 Karl Storz 11302 BND1 Video Scope - Engineer's Report : Optical System - Blurred, Angulation - Strained, Insertion Tube - Kinked, Temporary Plaster Repair, Light Transmission - No Fault Found View details Winning BidN/A Lot 70 Karl Storz 11302 BDD2 Video Scope - Engineer's Report : Optical System - Blurred, Angulation - No Fault Found, Insertion Tube - Minor Crush Marks, Light Transmission - No Fault Found View details Winning BidN/A Lot 71 Olympus URF Type P5 Ureteroscope - Engineer's Report : Optical System - Fluid Stain Present, Angulation - Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *2243503* View details Winning BidN/A Lot 72 Karl Storz 11302 BN1 Video Scope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Strained, Light Transmission - No Fault Found View details Winning BidN/A Lot 73 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Light Transmission - No Fault Found View details Winning BidN/A Lot 74 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Light Transmission - No Fault Found View details Winning BidN/A Lot 75 Karl Storz 11272 VUA Video Cystoscope in Case - Engineer's Report : Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check View details Winning BidN/A Lot 76 Karl Storz 11272 VNU Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check View details Winning BidN/A Lot 80 Olympus CYF-VH Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Channels - Channel Leak *2827359* View details Winning BidN/A Lot 82 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - Excessive Light Loss, Channels - No Fault Found, Leak Check - No Fault Found *2900328* View details Winning BidN/A Lot 83 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - 20% Light Loss, Channels - No Fault Found, Leak Check - No Fault Found *W047373* View details Winning BidN/A Lot 84 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - Dark Image, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800180* View details Winning BidN/A Lot 85 Olympus CF-240L Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930203* View details Winning BidN/A Lot 86 Olympus LF-2 Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2014001** View details Winning BidN/A Lot 87 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 8 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book View details StatusUnsold Lot 88 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 7 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book View details StatusUnsold Lot 89 Olympus IF11C5-3000 3 Meter Industrial Fiberscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Guide Tube - No Fault Found, Control Body and Cosmetics - Like New, Other Comments - Supplied with 8 Viewing Heads of 3 Different Fields of View, Like New Scope with Instruction Book View details StatusUnsold Lot 90 Job Lot Including 5 x Olympus MAJ-901 Water Containers and 1 x Olympus MAJ-902 Water Container View details Winning BidN/A Lot 91 Olympus MAJ-1154 Pigtail Connector (Loose Casing) View details Winning BidN/A Lot 92 Olympus MAJ-1911 Pigtail Connector View details Winning BidN/A Lot 93 Job Lot Including 1 x Olympus MU-1 Maintenance Unit with Leakage Tester Cable (Powers Up), 2 x Soluscope OL-LF-TP Connexions, 4 x Pentax Waterproof Caps, 8 x Pentax Valves and 1 x CCS K10009118 Cable View details Winning BidN/A Lot 94 Olympus ENF-XP Pharyngoscope in Case - Engineer's Report : Optical System - 14 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *2314149* View details Winning BidN/A Lot 95 Pentax ECY-1570K Video Cystoscope in Carry Case - Engineer's Report : Optical System -No Fault Found, Angulation - No Fault Found, Insertion Tube -Worn, Light Transmission - Plug Separate from Light Guide Tube, Channels - No Fault Found, Leak Check -No Fault Plug Leak *SN G120280* *Mfd NA * View details Winning BidN/A Lot 96 Karl Storz VN06030AEMV Video Scope with 2 x 0 Degree Optical Lenses and 2 x 90 Degree Optical Lenses in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - No Fault Found View details StatusUnsold Lot 97 Olympus CYF-3 Cystoscope - Engineer's Report : Optical System - 15% Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W501006* View details StatusUnsold Lot 98 Richard Wolf 7330.072 Intubation Scope - Engineer's Report : Optical System - Fluid Stain and Lens Separation, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check *142669* View details StatusUnsold Lot 99 Karl Storz VN06030AEMW Video Scope with 2 x 0 Degree Optical Lenses and 2 x 90 Degree Optical Lenses in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - No Fault Found View details Winning BidN/A Lot 100 Karl Storz VN06030AEMW Video Scope with 2 x 0 Degree Optical Lenses and 2 x 90 Degree Optical Lenses in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - No Fault Found View details Winning BidN/A Lot 101 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Image, Angulation - Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930475* View details Winning BidN/A Lot 102 Karl Storz VN06030AEMW Video Scope with 2 x 0 Degree Optical Lenses and 2 x 90 Degree Optical Lenses in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Leak Check - No Fault Found View details Winning BidN/A Lot 103 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Catch in Bio Channel, Leak Check - No Fault Found *2600430* **6522-894** View details Winning BidN/A Lot 104 Olympus ENF-GP Rhinolaryngoscope in Case - Engineer's Report : Optical System - 20 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kinks and Bad Crush Present, Light Transmission - No Fault Found, Leak Check - Excessive Body Leak *2612220* View details StatusUnsold Items per page 102550100100 Previous|1|Next Previous 11 Next Previous 11 Next