BRITISH MEDICAL AUCTIONS September 2022 Endoscopy (#551) 06/09/2022 1:40 PM BST - 15/09/2022 1:46 PM BST CLOSED Starts Ending 15/09/2022 1:00 PM BST Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-28 of 28. Previous|1|Next Lot 1 Olympus GIF-N260 Video Gastroscope with EndoMed Leak Tester in Case - Engineer's Report : Optical System - Cloudy Image, Angulation - Down Requires Adjustment, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2610551* View details StatusUnsold Lot 2 Olympus URF-V Video Urethroscope - Engineer's Report : Optical System - Unable to Check, Angulation - Strained, Not Reaching Specification, Insertion Tube - Crushed, Light Transmission - 20% Loss, Channels - Restricted, Leak Check - No Fault Found *W350852* View details Winning BidN/A Lot 3 Fujinon EC-530MP Video Colonoscope - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *656A028* View details Winning BidN/A Lot 4 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2830443* View details Winning BidN/A Lot 5 Fujinon EG-590WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *348A854* View details Winning BidN/A Lot 6 Olympus GIF-XK240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2400781* View details Winning BidN/A Lot 7 Olympus GIF-XK240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Play, Not Reaching Specification, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *230779* View details Winning BidN/A Lot 8 Vision Sciences TNE-2000 Rhinolaryngoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - Severely Crushed, Light Transmission - 20% Loss, Channels - Restricted, Leak Check - Leaking Light Guide Tube, Other Comments - Light Guide Tube Torn View details StatusUnsold Lot 9 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Channels - N/A, Leak Check - Unable to Check Due to Missing Bending Section Rubber *2840524* View details Winning BidN/A Lot 10 Olympus ENF-P4 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink, Bending Section Rubber Leaking, Light Transmission - No Fault Found, Channels - N/A, Leak Check - Leak Present from Bending Section Rubber *W011338* View details Winning BidN/A Lot 11 Olympus CF-2T200 Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Slightly Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2610550* View details Winning BidN/A Lot 12 Pentax ECY-1570K Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Channels - 1 x Jammed Valve, Leak Check - No Fault Found *G120320* View details StatusUnsold Lot 13 Pentax ECY-1570K Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G120318* View details Winning BidN/A Lot 14 Pentax ECY-1570K Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G120319* View details StatusUnsold Lot 15 Olympus Evis Lucera Elite GIF-HQ290 Video Gastroscope *Mfd - 2018* in Case - Engineer's Report - Optical System - No Fault Found - Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - In Excellent Condition - Like New *2736700* View details StatusUnsold Lot 16 Olympus Evis Lucera Elite GIF-H290 Video Gastroscope *Mfd - 2016* in Case - Engineer's Report - Optical System - No Fault Found - Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - In Excellent Condition - Like New *2645608* View details StatusUnsold Lot 17 Olympus ENF-P4 Pharyngoscope - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Kninked, Light Transmission - No Fault Found, Leak Check - No Fault Found *2724979* View details Winning BidN/A Lot 18 Olympus ENF-P4 Pharyngoscope - Engineer's Report : Optical System - No Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - Leak Present *W800582* View details Winning BidN/A Lot 19 Olympus ENF-P4 Pharyngoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W800577* View details Winning BidN/A Lot 20 Olympus ENF-P4 Pharyngoscope - Engineer's Report : Optical System - No Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked at Grip, Light Transmission - No Fault Found, Leak Check - No Fault Found *W800554* View details Winning BidN/A Lot 21 Olympus ENF-P4 Pharyngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *2825048* View details Winning BidN/A Lot 22 Olympus CF-200HL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2110169* View details Winning BidN/A Lot 23 Olympus JF-V2 Video Duodenoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700025* View details StatusUnsold Lot 24 Olympus GIF-UM2000 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unable to Check Ultrasonics *1830850* View details StatusUnsold Lot 50 Olympus ENF-P4 Pharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Minor Crush Mark Present, Light Transmission - No Fault Found, Leak Check - Unable to Check Due to Missing Bending Section Rubber *W011341* View details Winning BidN/A Lot 51 Pentax ECY-1575K Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120378* View details Winning BidN/A Lot 52 Pentax ECY-1575K Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120374* View details Winning BidN/A Lot 53 Pentax ECY-1575K Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *H120375* View details Winning BidN/A Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next