BRITISH MEDICAL AUCTIONS September 2022 Mixed Medical Equipment Part 2 (#549) 22/09/2022 11:00 AM BST - 28/09/2022 5:31 PM BST CLOSED Starts Ending 28/09/2022 10:05 AM BST Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-46 of 46. Previous|1|Next Lot 43 Olympus WM-M260 Mobile Workstation with 1 x Olympus OTV-S4 Camera Unit, 1 x Olympus CLV-S20 Light Source, 1 x Sony UP-2850P Color Video Printer and 1 x Olympus OTV-24 Camera with 1 x AR-TF2 Coupler and 1 x Olympus ECS-260 Connection Lead (All Power Up) View details Winning BidN/A Lot 44 Olympus Mobile Workstation with 1 x Olympus CLV-260 Light Source (Powers Up) 2 x Sony DVO-1000MD DVD Recorders (All Power Up 1 with Damaged Button-See Photo) View details Winning BidN/A Lot 74 Olympus WMNP2 Stack Trolley (Powers Up) *S/N 21321220* View details Winning BidN/A Lot 92 Job Lot Including 1 x Olympus OEV191H HD LCD Monitor (Powers Up with Damage to Screen - See Photos) 2 x Panasonic LQ-MD800 DVD Video Recorders (Both Power Up) 1 x JVC BD-X201M DVD Recorder and 1 x Olympus EICP-D DVD Unit (Powers Up) *SN 7820579 / B5TA00498 / 7848641 / C5TA00552 / 07050043* View details Winning BidN/A Lot 172 Karl Storz 22220055 Image HD1 H3 Camera Head *S* **SN KC725773-H** View details Winning BidN/A Lot 173 Job Lot Including 1 x Karl Storz Xenon Nova 175 201315 20 Light Source (No Power) and 2 x Karl Storz Pressure Caps *S* **SN FB0644045** View details Winning BidN/A Lot 175 Karl Storz 22220055 Image1 HD H3 Camera Head *SN AA745925-H* View details Winning BidN/A Lot 176 Karl Storz Image 1 22220030 PAL S3 Camera Head *SN ID646525-H* View details Winning BidN/A Lot 178 Job Lot Including 1 x Karl Storz Endoskope AIDA control 200960 20 Unit (Powers Up, HDD Removed) and 1 x Richard Wolf 5124 LP Endoscope Light Source (No Power) *S* **SN R1659871 / 040223** View details StatusUnsold Lot 192 Olympus CLV-S20 Light Source (Powers Up, No Bulb, Small Crack in Casing - See Photos) View details StatusUnsold Lot 193 JVC KY-F58 Camera Control Unit (Powers Up) View details StatusUnsold Lot 194 Firefly KT2130 Wireless Veterinary Endoscopy Set Including Wireless Endo-Camera, Rigid Endoscope, Endoscope Jacket, Wireless LED Light Source, Wireless Receiver, Software and Charging Cables in Case (Excellent Condition - Like New) View details Winning BidN/A Lot 195 DP Medical XE 50 eco X TFT-USB Camera Control / Light Unit (Powers Up) View details Winning BidN/A Lot 233 Wassenburg Medical Dry 300 Pass Through Drying Cabinet (Unable to Power Test Due to Cut Power Supply) *G* View details StatusUnsold Lot 256 Stryker Stack Trolley (Powers Up) View details Winning BidN/A Lot 257 Stryker Stack Trolley (Powers Up) View details Winning BidN/A Lot 258 Stryker Stack Trolley (Powers Up) View details Winning BidN/A Lot 259 Job Lot Including 1 x Olympus TI-1900 Image Trolley, 1 x CTLStack Trolley and 1 x ERBE Vio-Cart Trolley View details Winning BidN/A Lot 267 Mixed Lot Including 1 x CTL Medical Stack Trolley and 1 x Welch Allyn Propaq CS Monitor Including ECG, SpO2, NIBP, T1 and T2 Options with 1 x NIBP Hose, 1 x BP Cuff, 1 x SpO2 Finger Sensor and 1 x AC Power Supply on Stand (Powers Up) *SN GA115807, 8590* View details StatusUnsold Lot 268 Stryker Micro Cart with 2 x Stryker Cross Flow Footswitches and 1 x Smith & Nephew Footswitch View details Winning BidN/A Lot 337 LTE Scope Store Scope Cleaning Cabinet Software Version V1.4.1 (Powers Up) *GL* View details StatusUnsold Lot 349 Karl Storz OR 1 Cabinet with Storz 200971 20 SCB OR1 Control Neo Unit (HDD REMOVED), Storz 200461 20 AIDA Control Neo Unit (HDD REMOVED), Storz 200901 20 SCB Interface Control Unit and Storz 200921 32 AIDA Interface II Unit View details StatusUnsold Lot 351 Karl Storz Stack System Including 1 x Karl Storz Endoskope Wide View HD Monitor, 1 x Karl Storz Endoskope 200903 31 Monitor ,1 x Karl Storz Endoskope AIDA Control 200960 20 Control Unit, 1 x Karl Storz Endoskope 201340 20 xenon nova 300 Light Source, 1 x Ricoh SG 2100N Printer and 1 x Karl Storz Endoskope 22220050 H3 image 1 HD Camera on Trolley 1 x Karl Storz Endoskope 222010 20 SCB image 1 hub (Powers Up, image 1 hub No Power) *SN09134292, R1537600, CA660471-P, ED06222158, FD0109* View details Winning BidN/A Lot 352 Karl Storz Stack System Including 1 x Karl Storz Endoskope Wide View HD Monitor, 1 x Karl Storz Endoskope 200903 31 Monitor ,1 x Karl Storz Endoskope AIDA Control 200960 20 Control Unit, 1 x Karl Storz Endoskope 201315 20 xenon nova Light Source and 1 x Karl Storz 222010 20 SCB image 1 Unit (All Powers Up) *SN 09135568, R1548611, CH1311131, BA659537* View details Winning BidN/A Lot 353 Karl Storz Stack System Including 1 x Karl Storz Endoskope Wide View HD Monitor, 1 x Karl Storz Endoskope 200903 31 Monitor ,1 x Karl Storz Endoskope AIDA Control 200960 20 Control Unit, 1 x Karl Storz Endoskope 222010 20 scb Image 1 hub Unit, 1 x Karl Storz Endoskope 201340 20 xenon nova 3000 Light Source and 1 x Karl Storz H3 Image 1 HD Camera (Powers Up) View details Winning BidN/A Lot 354 Lancer Getinge Group Endoscopy Stainless Storage Trolley View details Winning BidN/A Lot 361 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710856* View details Winning BidN/A Lot 362 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800590* View details Winning BidN/A Lot 363 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check Due to Plug Fault, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600411* View details Winning BidN/A Lot 364 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800595* View details Winning BidN/A Lot 365 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700501* View details Winning BidN/A Lot 366 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2735416* View details Winning BidN/A Lot 367 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2622930* View details Winning BidN/A Lot 368 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710863* View details Winning BidN/A Lot 369 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2622903* View details Winning BidN/A Lot 370 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2622901* View details Winning BidN/A Lot 371 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600458* View details Winning BidN/A Lot 372 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600461* View details Winning BidN/A Lot 374 Vision Sciences TNE-2000 Rhinolaryngoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - Severely Crushed, Light Transmission - 20% Loss, Channels - Restricted, Leak Check - Leaking Light Guide Tube, Other Comments - Light Guide Tube Torn View details Winning BidN/A Lot 375 Pentax ECY-1570K Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Channels - 1 x Jammed Valve, Leak Check - No Fault Found *G120320* View details Winning BidN/A Lot 377 Olympus Evis Lucera Elite GIF-HQ290 Video Gastroscope *Mfd - 2018* in Case - Engineer's Report - Optical System - No Fault Found - Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - In Excellent Condition - Like New *2736700* View details StatusUnsold Lot 378 Olympus Evis Lucera Elite GIF-H290 Video Gastroscope *Mfd - 2016* in Case - Engineer's Report - Optical System - No Fault Found - Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - In Excellent Condition - Like New *2645608* View details StatusUnsold Lot 379 Olympus JF-V2 Video Duodenoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700025* View details Winning BidN/A Lot 380 Olympus GIF-UM2000 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unable to Check Ultrasonics *1830850* View details Winning BidN/A Lot 419 Wassenburg AERclens Washer with Printer View details Winning BidN/A Lot 420 Wassenburg AERclens Washer with Printer View details StatusUnsold Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next