BRITISH MEDICAL AUCTIONS August 2022 Endoscopy (#540) 12/08/2022 3:00 PM BST - 18/08/2022 3:52 PM BST CLOSED Starts Ending 18/08/2022 1:04 PM BST Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-81 of 81. Previous|1|Next Lot 1 Lawton 49-0025 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 2 Endoscopic London A2054/2 00 0 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 3 Richard Wolf 888.0543 Panview 4.0 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 4 Richard Wolf 888.0543 Panview 4.0 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 5 Richard Wolf 888.0543 Panview 4.0 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 6 Richard Wolf 888.0543 Panview 4.0 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 7 Richard Wolf 888.0543 Panview 4.0 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 8 Richard Wolf 888.0543 Panview 4.0 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 9 Stryker 342-31 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 10 Uroplasty MPS-130 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 11 ConMed HD1030 UHD 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 12 Reda R010-050302-000 0 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 13 M3 30A 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 14 ASAP SemiFlex 12 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 15 Karl Storz Hopkins II 27005CA E-Class 70 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 16 Karl Storz Hopkins 27005BA 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 17 Karl Storz Hopkins 27005BA 30 Degree Rigid Endoscope (Clear View) View details Winning BidN/A Lot 19 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2321236* View details Winning BidN/A Lot 20 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Missing Badge *2533323* View details Winning BidN/A Lot 21 Olympus GIF-Q260 Video Gastroscope - in Case Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indents Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *27452872* View details Winning BidN/A Lot 22 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Minor Crush Marks in Light Guide Tube *2410092* View details Winning BidN/A Lot 23 Olympus TJF-260V Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2901017* View details Winning BidN/A Lot 24 Olympus TJF-260V Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500056* View details Winning BidN/A Lot 25 Olympus GIF-Q260 Video Gastroscope - in Case Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2644531* View details Winning BidN/A Lot 26 Olympus PCF-240AL Pediatric Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2200028* View details Winning BidN/A Lot 27 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800179* View details Winning BidN/A Lot 28 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2200704* View details Winning BidN/A Lot 29 Olympus BF-1T240 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indents Present, Light Transmission - No Fault Found, Channels - Bio Channel Blocked, Leak Check - No Fault Found *2800417* View details Winning BidN/A Lot 30 Olympus GIF-UCT240 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unable to Check Ultrasound Feature *1800210* View details Winning BidN/A Lot 31 Olympus GF-UE260 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Play, Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unable to Check Ultrasound Feature *1910312* View details Winning BidN/A Lot 32 Olympus GIF-UCT240 Ultrasound Video Gastroscope in Case - Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unable to Check Ultrasound Feature *1000323* View details Winning BidN/A Lot 33 Olympus GIF-UC240P Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unable to Check Ultrasound Feature *1100017* View details Winning BidN/A Lot 34 Karl Storz 11272VP Video Urethro-Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check, Leak Check - Unable to Check *22326* View details Winning BidN/A Lot 35 Olympus CF-200HL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2110169* View details StatusUnsold Lot 36 Olympus JF-V2 Video Duodenoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700025* View details StatusUnsold Lot 37 Olympus URF-P5 Urethroscope in Case - Engineer's Report : Optical System - 0 Broken Fibers, Fluid Stain Present, Angulation - Bending Section Distorted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2701189* View details Winning BidN/A Lot 38 Reister Nasal Scope in Case - Engineer's Report : Optical System - 22 Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Crush in Bending Section, Light Transmission - No Fault Found, Leak Check - Unable to Check *407292* View details Winning BidN/A Lot 39 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2723821* View details Winning BidN/A Lot 40 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Bite Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2242814* View details Winning BidN/A Lot 41 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Glue Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2745243* View details Winning BidN/A Lot 42 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indentations Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2745247* View details Winning BidN/A Lot 43 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2244098* View details Winning BidN/A Lot 44 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Crush Mark in Light Guide Tube *2242810* View details Winning BidN/A Lot 45 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2745245* View details Winning BidN/A Lot 46 Karl Storz Flex X2 Ureteroscope in Case - Engineer's Report : Optical System - 0 Broken Fibers, Stain on Image, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Channels - Unable to Check, Leak Check - Unable to Check *2133543* View details Winning BidN/A Lot 47 Olympus CYF-5 Cystoscope with Light Guide Cable - Engineer's Report : Optical System - 6 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W703517* View details Winning BidN/A Lot 48 Olympus CYF-5 Cystoscope with Light Guide Cable - Engineer's Report : Optical System - 4 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W602927* View details Winning BidN/A Lot 49 Olympus URF-P5 Urethroscope in Case - Engineer's Report : Optical System - 10 Broken Fibers, Angulation - Distorted, Insertion Tube - Crush at Body, Light Transmission - No Fault Found, Channels - Catching, Leak Check - Excessive Leak Present *W800237* View details Winning BidN/A Lot 50 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2100021* View details Winning BidN/A Lot 51 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Wrinkled at Body, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2410150* View details Winning BidN/A Lot 52 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2100020* View details Winning BidN/A Lot 53 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300142* View details Winning BidN/A Lot 54 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - L/R Brake Faulty, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300143* View details Winning BidN/A Lot 55 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800295* View details Winning BidN/A Lot 56 Pentax EC-3830LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check *C12349* View details Winning BidN/A Lot 57 Pentax VNL-1170K Rhinolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G120171* View details Winning BidN/A Lot 59 Pentax Video Gastroscope in Case (Unknown Model) - Engineers Report : Optical System - Interference, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 60 Tyrui Technology LinkView 1200 Camera & 100W LED Light Source Combo Console with Camera (Powers Up with Good Bulb, Loose Camera Connector - See Photo) View details Winning BidN/A Lot 61 Tyrui Technology LinkView 1200 Camera & 100W LED Light Source Combo Console with Camera (Powers Up with Good Bulb) View details Winning BidN/A Lot 62 Tyrui Technology LinkView 1080 Camera & 100W LED Light Source Combo Console with Camera (Powers Up with Good Bulb) View details Winning BidN/A Lot 63 Olympus Stack System Including 1 x Olympus OEV191H Monitor, 1 x Olympus MAJ-1156 Keyboard, 1 x Olympus MAJ-1154 Pigtail Connector, 1 x Olympus Evis Lucera CV-260 Processor and 1 x Olympus Evis Lucera CLV-260 Light Source (All Powers Up) View details Winning BidN/A Lot 64 Job Lot Including 1 x Olympus MAJ-1156 Keyboard, 1 x Olympus MAJ-1154 Pigtail Connector, 1 x Olympus Evis Lucera CV-260 Processor and 1 x Olympus Evis Lucera CLV-260 Light Source (Both Power Up) View details Winning BidN/A Lot 65 Pentax EPK-1000 Video Processor (Powers Up) View details Winning BidN/A Lot 66 2 x Endoscopic Pigtail Connectors View details Winning BidN/A Lot 69 1 x Karl Storz 20100032 / 20100032 Light Source Adapter for connecting to Storz Video Endoscope View details Winning BidN/A Lot 70 Mixed Lot Including 1 x Olympus Model CLH-2 Halogen Light Source (Powers Up) 1 x Olympus Heat Probe Unit with 1 x Olympus MAJ-528 Footswitch (Powers Up with Fault-See Photo) View details Winning BidN/A Lot 71 2 x Olympus ECS-260 Endoscopy Cables View details Winning BidN/A Lot 72 Job Lot Including 1 x Olympus OTV-S4 Digital Signal Processing Unit, 1 x Olympus CLV-S20 Light Source Unit and 1 x Olympus CLV-U20 Universal Light Source Unit (All Power Up) View details StatusUnsold Lot 73 Olympus GIF-UM2000 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unable to Check Ultrasonics *1830850* View details StatusUnsold Lot 74 Pentax FI-13P Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A01002* View details StatusUnsold Lot 77 Olympus Stack Trolley with 1 x Olympus OEV191 Monitor, 1 x Olympus Keyboard and 1 x Olympus Visera OTV-S7 Digital Processor (Powers Up) *7785832 / 7721342* View details StatusUnsold Lot 78 Olympus WM-260 Mobile Workstation Stack Trolley (Powers Up) with Olympus OEV261H Monitor (Untested Due to No Power Supply) View details Winning BidN/A Lot 79 Olympus Stack System Including 1 x Olympus OEV262H Monitor, 1 x Olympus Evis OVC-200 Lecturescope, 2 x Olympus MAJ-1154 Pigtail Connectors, 1 x Olympus Keyboard, 1 x Olympus Evis Lucera CV-260SL Processor and 1 x Olympus Evis Lucera CLV-260 Light Source on 2 x Stack Trolleys (All Power Up) View details Winning BidN/A Lot 80 Olympus Stack Trolley with 1 x Olympus OEV191 Monitor, 1 x Olympus Keyboard (Missing Keys), 1 x Olympus Visera OTV-S7 Digital Processor, 1 x Olympus Visera CLV-S40 Light Source, 1 x Olympus A10-T1 Video Adapter and 1 x Sedlbauer MTT 1000 UPS (Powers Up) *7729738 / 7200268 / 7785833* View details StatusUnsold Lot 81 Olympus Compact Trolley with Olympus OEV191H Monitor, Olympus Visera CLV-S40 Light Source, Olympus Visera OTV-S7 Digital Signal Processor, Sony UP-21MD Color Video Printer and Sony DVO-1000MD DVD Recorder (Powers Up) *S/N 7825086 / 7884407* View details Winning BidN/A Lot 82 Olympus TC-C1 Clinical Trolley with Sony Trinitron PVM-14M2MDE Monitor, Olympus OTV-S6 Advanced Digital Multi Processor, Olympus CLH-250 Light Source, Sony Color Video Printer UP-21MD and Sony Digital Videocassette Recorder DSR-20MDP (All Power Up) *S/N 2102310 / 7123080 / 7227165* View details StatusUnsold Lot 83 Olympus Stack Trolley with Olympus OEV181H Monitor, Olympus ECS-260 Connector Cable, Sony UP-25MD Colour Video Printer and Sony Digital Video Cassette Recorder (Powers Up) View details Winning BidN/A Lot 84 Pentax Stack Trolley with Sony Trinitron Monitor, Pentax LH-150II Light Source, Pentax PSV-4000 Camera Control Unit, Pentax Camera Head and Sony UP-21MD Colour Video Printer (Powers Up) View details Winning BidN/A Lot 85 Olympus CLV-S30 Xenon Light Source with Leica Camera Control Unit (Powers Up with Good Bulb) View details Winning BidN/A Lot 86 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Discoloured, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2421573* View details Winning BidN/A Lot 87 Olympus GIF-XQ230 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2603032* View details Winning BidN/A Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next