BRITISH MEDICAL AUCTIONS June 2022 Endoscopy Part 2 (#521) 21/06/2022 2:00 PM BST - 27/06/2022 2:30 PM BST CLOSED Starts Ending 27/06/2022 1:06 PM BST Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-46 of 46. Previous|1|Next Lot 1 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800186* View details Winning BidN/A Lot 2 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2610391* View details Winning BidN/A Lot 3 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2310055* View details Winning BidN/A Lot 4 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2522628* View details Winning BidN/A Lot 5 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W700195* View details Winning BidN/A Lot 6 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W700169* View details Winning BidN/A Lot 7 Olympus CYF-V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W700201* View details Winning BidN/A Lot 8 Olympus CHF-P60 Choledocoscope in Case - Engineer's Report : Optical System - 8 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Leaking, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak From Bending Section Rubber *2800126* View details Winning BidN/A Lot 9 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2948359* View details Winning BidN/A Lot 10 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kinks / Ripples, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710719* View details Winning BidN/A Lot 11 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2410106* View details Winning BidN/A Lot 12 Olympus GIF-UM2000 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unable to Check Ultrasonics *1830850* View details StatusUnsold Lot 13 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - Image OK, Head Functions Inoperative, Angulation - No Fault Found, Light Transmission - No Fault FOund, Channels - No Fault Found, Leak Check - No Fault Found *2710704* View details Winning BidN/A Lot 14 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710728* View details Winning BidN/A Lot 15 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2911250* View details Winning BidN/A Lot 16 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2911286* View details Winning BidN/A Lot 17 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710721* View details Winning BidN/A Lot 18 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710727* View details Winning BidN/A Lot 19 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2410075* View details Winning BidN/A Lot 20 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2911242* View details Winning BidN/A Lot 21 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Ripples, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2610420* View details Winning BidN/A Lot 22 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2911280* View details Winning BidN/A Lot 23 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2410080* View details Winning BidN/A Lot 24 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300182* View details Winning BidN/A Lot 25 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2510124* View details Winning BidN/A Lot 26 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2948359* View details Winning BidN/A Lot 27 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - 11 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W247916* View details Winning BidN/A Lot 28 Olympus BF-P40 Bronchoscope - Engineer's Report : Optical System - 1 Broken Fiber and Minor Stain Present, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1031635* View details Winning BidN/A Lot 29 Pentax FNL-10RP3 Laryngoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *A111414* View details Winning BidN/A Lot 30 Pentax FNL-10RP3 Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks Present, Excessive Leak in Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Excessive Leak from Bending Section Rubber *A111413* View details Winning BidN/A Lot 31 Olympus CF-200HL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2110133* View details Winning BidN/A Lot 32 Olympus LF-GP Laryngoscope in Case - Engineer's Report : Optical System - 7 Broken Fibers and Fluid / Dirt Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Slow Tube Leak Present *1413685* View details StatusUnsold Lot 33 Vision Sciences ENT-2000 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Leak Check - Unable to Check *J1628P* View details Winning BidN/A Lot 34 Baxter 1 Meter Ultrafine Scope in Case - Engineer's Report : Optical System - Blurred, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - Unable to Check View details StatusUnsold Lot 35 Olympus CHF-PQ20 Choledocoscope - Engineer's Report : Optical System - Blurred Image, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking Tube *2420446* View details StatusUnsold Lot 36 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *5707-894* View details Winning BidN/A Lot 37 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *5707-894* View details StatusUnsold Lot 38 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *5707-894* View details StatusUnsold Lot 39 Olympus LS-10R Teaching Attachment in Case View details StatusUnsold Lot 40 Vision Sciences TNE-2000 Rhinolaryngoscope in Case - Engineer's Report : Optical System - Multiple Broken Fibers, Angulation - Snaking, Insertion Tube - Multiple Crushed Sections, Light Transmission - Loss of Light, Channels - Blocked, Leak Check - No Fault Found, Other Comments - Light Guide Coating Damaged *T02745* (H) View details StatusUnsold Lot 41 Vision Sciences TNE-2000 Rhinolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Requires Adjustment, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - Leak Present from Bending Section Rubber, Other Comments - Crushed Light Tube *T0278S* (H) View details Winning BidN/A Lot 42 Vision Sciences TNE-5000 Rhinolaryngoscope in Case - Engineer's Report : Optical System - Untested, Angulation - Damaged Bending Section, Insertion Tube - Bending Section Damaged, No Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Untested But Suspect Leak will be Present *TE30116P* (H) View details StatusUnsold Lot 43 Vision Sciences TNE-5000 Rhinolaryngoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - Untested *TE40113P* (H) View details Winning BidN/A Lot 44 Vision Sciences TNE-5000 Rhinolaryngoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found, Other Comments - Damage to Parts on Control Body *350108* (H) View details Winning BidN/A Lot 45 Vision Sciences TNE-2000 Rhinolaryngoscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Leak Check - Light Guide Tube Torn and Leaking *T0226P* (H) View details StatusUnsold Lot 46 Pentax FI-13P Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A01002* View details StatusUnsold Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next