BRITISH MEDICAL AUCTIONS February 2022 Endoscopy (#484) 23/02/2022 2:30 PM GMT - 28/02/2022 2:42 PM GMT CLOSED Starts Ending 28/02/2022 1:06 PM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-64 of 64. Previous|1|Next Lot 1 Olympus TJF-240 Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800109* View details Winning BidN/A Lot 2 Olympus BF-260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2601242* View details Winning BidN/A Lot 3 Olympus CF-240L Video Colonoscope in Case - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800254* View details Winning BidN/A Lot 4 Olympus ENF-GP Nasopharyngoscope in Box - Engineer's Report : Optical System - 6 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinked and Bad Twist Near Bending Section Where Leaking, Light Transmission - No Fault Found, Leak Check - Leak Present from Insertion Tube *1301411* View details Winning BidN/A Lot 6 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber and Very Minor Stain, Angulation - No Fault Found, Insertion Tube - Minor Kink and Minor Crush Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901890* View details Winning BidN/A Lot 8 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901866* View details Winning BidN/A Lot 9 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 4 Broken Fibers and Slight Stain, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901878* View details Winning BidN/A Lot 11 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901913* View details Winning BidN/A Lot 12 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901905* View details Winning BidN/A Lot 13 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901892* View details Winning BidN/A Lot 14 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *1100639* View details Winning BidN/A Lot 15 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901890* View details Winning BidN/A Lot 16 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901891* View details Winning BidN/A Lot 18 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber and Minor Stain, Angulation - No Fault Found, Insertion Tube - Minor Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901894* View details Winning BidN/A Lot 19 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Kinks and Crush Mark Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901893* View details Winning BidN/A Lot 20 Olympus LF-GP Laryngoscope with Olympus MAJ-524 Portable Light Source (Powers Up) in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W700416* View details Winning BidN/A Lot 21 Olympus LF-GP Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Slightly Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1413835* View details Winning BidN/A Lot 22 Olympus LF-GP Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink, Light Transmission - No Fault Found, Channels - Leaking, Leak Check - Slow Leak from Channel and Eyepiece *W001096* View details Winning BidN/A Lot 23 Olympus LF-GP Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Leaking Bending Section Rubber, Minor Indentations, Light Transmission - No Fault Found, Channels - Leaking, Leak Check - Leaks Present *W001104* View details Winning BidN/A Lot 24 Olympus CF-240AL Video Colonoscope in Case - Engineer's Report : Optical System - Image Ok, Head Functions Inoperable, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2320646* View details Winning BidN/A Lot 27 Pentax EC-3840L Video Colonoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Crushed and Kinked Light Guide Tube, *A01093* View details Winning BidN/A Lot 29 Pentax FNL-10RP3 Laryngoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Unable to Check Due to Missing Bending Section Rubber *G114981* View details Winning BidN/A Lot 30 Olympus LF-P Laryngoscope - Engineer's Report : Optical System - 5 Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Leaking, Light Transmission - No Fault Found, Leak Check - Leaking from Bending Section Rubber *2821619* View details StatusUnsold Lot 31 Olympus LF-P Laryngoscope - Engineer's Report : Optical System - Massive Amount of Broken Fibers, Angulation - Not Reaching Specification, Insertion Tube - Bad Crush Marks, Light Transmission - Poor, Leak Check - No Fault Found *2521432* View details Winning BidN/A Lot 32 Olympus ENF-XP Pharyngoscope - Engineer's Report - Optical System - Over 40 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Severely Crushed and Split, Light Transmission - Poor, Leak Check - Leak from Split *2511798* View details Winning BidN/A Lot 33 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report - Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2710319* View details Winning BidN/A Lot 34 Olympus PCF-230 Video Colonoscope in Case - Engineer's Report - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500122* View details Winning BidN/A Lot 35 Olympus LF-V Flexible Intubation Endoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak Present *2010324* View details Winning BidN/A Lot 36 Olympus PCF-240S Video Sigmoidoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800293* View details Winning BidN/A Lot 37 Olympus PCF-240S Video Sigmoidoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800294* View details Winning BidN/A Lot 38 Olympus GIF-XK240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900136* View details Winning BidN/A Lot 39 Olympus CHF Type P20 Flexible Chloedochoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Severely Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1320879* View details StatusUnsold Lot 40 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report - Optical System - Condensation Within Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2336770* View details Winning BidN/A Lot 41 Pentax FI-16BS Fiber Intubation Scope in Case - Engineer's Report - Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *N/A* View details Winning BidN/A Lot 42 Olympus CYF-2 Cystoscope in Case - Engineer's Report : Optical System - Over 20 Broken Fibers and Bad Fluid Stain Present, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube, No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W101059* View details StatusUnsold Lot 43 Olympus GIF-Q230 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indents, Light Transmission - No Fault Found, Channels - Biopsy Dial Totally Blocked at Top End, Leak Check - No Fault Found *2400322* View details Winning BidN/A Lot 45 Pentax FI-13RBS Fiber Intubation Scope with Pentax BS-LH2 Portable Light Source (Untested Due to No Battery) in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Marks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G110085* View details Winning BidN/A Lot 46 Olympus GIF-X200 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2400485* View details Winning BidN/A Lot 49 Olympus TJF-200 Video Duodenoscope in Case - Engineer's Report - Optical System - Image Ok, Head Functions Faulty, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Strained and Sticky, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700927* View details Winning BidN/A Lot 51 Olympus Prototype 2 Meter Endoscope in Case - Engineer's Report - Optical System - 10 Broken Fibers and Yellowing Image, Angulation - Ok, Insertion Tube - Crush and Kink Marks Throughout, Channels - Unable to Check, Leak Check - No Fault Found *A11214* View details Winning BidN/A Lot 52 Pentax FI-10RBS Fiber Intubation Scope with Pentax BS-LH2 Portable Light Source (Untested Due to No Battery) in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111751* View details Winning BidN/A Lot 53 Olympus OSF-3 Sigmoidoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *23140010* View details Winning BidN/A Lot 55 Olympus GIF-XK200 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Sticky Light Guide Tube *2510786* View details StatusUnsold Lot 56 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *21000787* View details Winning BidN/A Lot 57 Pentax FNL-10RBS Laryngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Badly Kinked and Badly Crushed, Light Transmission - Poor, Leak Check - No Fault Found *G111980* View details Winning BidN/A Lot 58 Olympus GIF-XQ10 Gastroscope in Case - Engineer's Report : Optical System - Approx 150 Broken Fibers, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Badly Kinked, Light Transmission - Poor, Channels - Poor, Leak Check - Leaking Tube *2410248* View details Winning BidN/A Lot 59 Pentax EG-1870K Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Coating Perishing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking Insertion Tube *A120187* View details Winning BidN/A Lot 60 Olympus EndoCapsule Set Including 1 x RE-1 Unit and 1 x VE-1 Unit, Battery Charger, Docking Station and Accessories View details Winning BidN/A Lot 61 Olympus GF-UC240 Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Unused with All Accessories *1000329* View details StatusUnsold Lot 62 Olympus CF-FH260AZL HD 200M Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Has Option to use Auto-Fluorescence Imaging *2700106* View details StatusUnsold Lot 63 Pentax FCN-15X Choledochoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *B01361* View details Winning BidN/A Lot 64 Fujinon EG-450CT5 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Patient Tube - No Fault Found, Light Guide Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *230A039* View details StatusUnsold Lot 100 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901906* View details Winning BidN/A Lot 101 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901879* View details Winning BidN/A Lot 102 Olympus ENF-GP Nasopharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901898* View details Winning BidN/A Lot 103 Olympus ENF-GP Nasopharyngoscope in Case - Engineers Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901901* View details Winning BidN/A Lot 104 Optim Entity LED NasoView Nasopharyngoscope with 3 x Batteries, Battery Charger and Leak Tester in Case (Powers Up) - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *L0053A* View details Winning BidN/A Lot 105 Pentax EG-383IT Video Gastroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Unable to Check, Channels - No Fault Found, Leak Check - No Fault Found *E010028* View details Winning BidN/A Lot 106 Olympus GIF-XQ30 Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2402062* View details Winning BidN/A Lot 107 Pentax FI-16RBS Fiber Intubation Scope with Pentax BS-LC1 Light Cable in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G110153* View details Winning BidN/A Lot 108 Karl Storz 11292DE1 Choledocho-Fiberscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, *2178727* View details Winning BidN/A Lot 109 Pentax FB-15V Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G111819* View details Winning BidN/A Lot 110 Fujinon EG-530N Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *6G250A096* View details Winning BidN/A Lot 111 Fujinon EN-450T5 Enteroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *5C361A109* View details Winning BidN/A Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next