November 2021 Endoscopy Part 2 17/11/2021 11:00 AM GMT - 29/11/2021 2:28 PM GMT View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-49 of 49. Previous|1|Next Image Lot # Item Title Time Left Your Bids 1 Olympus SIF-Q240 Video Enteroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Leaking Bending Section Rubber, Light Transmission - No Fault Found, Channels - No Fault Found *2200055* 1 Winning BidN/AStatusSold View details 2 Pentax EG-3870UTK Ultrasound Video Gastroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Kinked, Channels - Unable to Check, Leak Check - Unable to Check, Other Comments - Wear on Transducer, Unable to Check Ultrasound Capability *A120478* 1 Winning BidN/AStatusSold View details 3 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800297* 1 Winning BidN/AStatusSold View details 4 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900301* 1 Winning BidN/AStatusSold View details 5 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2100049* 1 Winning BidN/AStatusSold View details 6 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2856790* 1 Winning BidN/AStatusSold View details 7 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2645198* 1 Winning BidN/AStatusSold View details 8 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2745232* 1 Winning BidN/AStatusSold View details 9 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800294* 1 Winning BidN/AStatusSold View details 10 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - L/R Brake Faulty, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2100039* 1 Winning BidN/AStatusSold View details 11 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - L/R Brake Faulty, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700280* 1 Winning BidN/AStatusSold View details 12 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2411947* 1 Winning BidN/AStatusSold View details 13 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2150206* 1 Winning BidN/AStatusSold View details 14 Olympus MH-908 Ultrasound Endoscope Probe in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check, Leak Check - Unable to Check, Other Comments - Unable to Check Ultrasound Capability *1110150* 1 Winning BidN/AStatusSold View details 15 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Insertion Tube - Kink at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Cracked Distal Cap *2900350* 1 Winning BidN/AStatusSold View details 16 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800293* 1 Winning BidN/AStatusSold View details 17 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800291* 1 Winning BidN/AStatusSold View details 18 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Distorted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800296* 1 Winning BidN/AStatusSold View details 19 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900299* 1 Winning BidN/AStatusSold View details 20 Olympus GF-UC240P Video Ultrasound Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - L/R Brake Faulty, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check, Leak Check - Unable to Check, Other Comments - Unable to Check Ultrasound Capability *1000010* 1 Winning BidN/AStatusSold View details 21 Olympus TJF-240 Video Duodenoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Bio Channel Restricted, Leak Check - Excessive Leak Present *2800145* 1 Winning BidN/AStatusSold View details 22 Olympus BF-240 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1040658* 1 Winning BidN/AStatusSold View details 23 Olympus GF-UCT240 Video Ultrasound Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable to Check, Other Comments - Unable to Check Ultrasound Capability *1200031* 1 Winning BidN/AStatusSold View details 24 Olympus TJF-20 Duodenoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - Excessive Play, Not Reaching Specification, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2211044* 1 Winning BidN/AStatusSold View details 25 Fujinon Unknown Model Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Strained and Stained, Light Transmission - No Fault Found, Channels - No Fault Found *308A026* 1 Winning BidN/AStatusSold View details 26 Olympus CF-Q240AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Tension with L/R Movement, Insertion Tube - Perforated Bending Section Rubber, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Perforated Bending Section Rubber *2110099* 1 Winning BidN/AStatusSold View details 27 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800185* 1 Winning BidN/AStatusSold View details 28 Olympus BF-1T240 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indentations, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1230898* 1 Winning BidN/AStatusSold View details 29 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification L/R, Bending Section Strained, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800169* 1 Winning BidN/AStatusSold View details 30 Microscopix Pharyngoscope in Case - Engineer's Report : Optical System - Grey Fibers and Dirt Specks Present, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Light Transmission - No Fault Found, Leak Check - Unable to Check *44834* 1 StatusUnsold View details 31 Olympus ENF-P4 Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked *1024994* 1 Winning BidN/AStatusSold View details 32 Fujinon EG-450WR5 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *201A298* 1 Winning BidN/AStatusSold View details 33 Pentax FG-38UX Ultrasound Gastroscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check, Lea kCHeck - Unable to Check, Other Comments - Unable to Check Ultrasound Capability *A110201* 1 Winning BidN/AStatusSold View details 34 Olympus CF-240AL Video Colonoscope - Engineer's Report : Vertical Line Interference, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2210548* 1 Winning BidN/AStatusSold View details 35 Karl Storz 11302 BDX Video Intubation Scope in Case - Engineer's Report : Optical System - Unable to Check, Insertion Tube - Broken Bending Section *69135* 1 Winning BidN/AStatusSold View details 36 Pentax EG-3870UTK Ultrasound Video Gastroscope in Case (Spares and Repairs) *A120479* 1 Winning BidN/AStatusSold View details 37 Olympus GF-UM20 Ultrasound Gastroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check, Leak Check - Unable to Check *1200166* 1 StatusUnsold View details 38 Fujinon EG-450WR5 Video Gastroscope in Case - Engineer's Report : Optical System - Interference on Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *201A044* 1 Winning BidN/AStatusSold View details 39 Fujinon EC-450WL5 Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Strained, Light Transmission - No Fault Found, Leak Check - No Fault Found *308A022* 1 Winning BidN/AStatusSold View details 40 Olympus CYF Type V Video Cystoscope in Case - Engineers Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Twisted 45 Degrees, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500338* 1 StatusUnsold View details 41 Olympus HYF Type P Hysterscope - Engineer's Report : Optical System - Excessive Broken Fibres, Angulation - Severely Crushed, Insertion Tube - Perished, Light Transmission - Poor, Leak Check - Excessive *SN 1100534* 1 Winning BidN/AStatusSold View details 100 Olympus GIF-1T20 Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found (S) *2111977* Winning BidN/AStatusSold View details 101 Olympus GIF-XQ20 Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2701305* Winning BidN/AStatusSold View details 102 Olympus CF-1T20L Colonoscope - Engineer's Report : Optical System - 10 Broken Fibers, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2543949* Winning BidN/AStatusSold View details 103 Olympus ENF-GP Pharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found (G) *W801276* Winning BidN/AStatusSold View details 104 Olympus ENF-GP Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found (G) *W505489* Winning BidN/AStatusSold View details 105 Olympus BF-1T260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700912* Winning BidN/AStatusSold View details 106 Olympus URF-P5 Urethroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found (S) *2755325* Winning BidN/AStatusSold View details 107 Olympus URF-P5 Urethroscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found (S) *2755328* Winning BidN/AStatusSold View details Items per page 102550100 Previous|1|Next Previous 1 Next