BRITISH MEDICAL AUCTIONS October 2021 Endoscopy Equipment (#432) 08/10/2021 5:00 PM BST - 13/10/2021 2:32 PM BST CLOSED Starts Ending 13/10/2021 1:02 PM BST Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-47 of 47. Previous|1|Next Lot 1 Karl Storz 27005 FA Hopkins 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (Clear View) *1209E4* View details Winning BidN/A Lot 2 Karl Storz 27005 FA E-Class 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (Slightly Cloudy View) *1058802* View details StatusUnsold Lot 3 Karl Storz 27005 FA Hopkins II 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (Slightly Cloudy View) *1717729* View details StatusUnsold Lot 4 Karl Storz 27005 FA Hopkins II 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (Slightly Cloudy View) *1716054* View details StatusUnsold Lot 5 Karl Storz 27005 FA Hopkins 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (Cloudy View and Marks Present) *1207EV* View details StatusUnsold Lot 6 Karl Storz 27005 FA Hopkins II 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (Very Cloudy View) *1509965* View details Winning BidN/A Lot 7 Karl Storz 27005 FA Hopkins II 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (Clear View) *120036* View details Winning BidN/A Lot 8 Karl Storz 27005 FA Hopkins 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (No View) *120711* View details Winning BidN/A Lot 9 Karl Storz 27005 FA Hopkins II 12 Degree Rigid Cystoscope with Olympus WA2P400A Protective Tube (Cloudy View and Marks Present) *1054119* View details StatusUnsold Lot 10 Karl Storz 27005 FA Hopkins 12 Degree Rigid Cystoscope (Cloudy View and Marks Present) *120919* View details StatusUnsold Lot 11 Karl Storz 27005 FA Hopkins 12 Degree Rigid Cystoscope (Very Cloudy View) *1202JH* View details Winning BidN/A Lot 12 Karl Storz 27005 FA Hopkins 12 Degree Rigid Cystoscope (Clear View) *1207SY* View details Winning BidN/A Lot 13 Olympus LF-TP Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W500012* View details Winning BidN/A Lot 14 Olympus LF-GP Laryngoscope in Case - Engineer's Report : Optical System - 0 Broken Fibers, Minor Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W201309* View details StatusUnsold Lot 15 Olympus TJF-260V Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Split, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Bending Section Rubber Leaking *2600110* View details Winning BidN/A Lot 16 Olympus LF-TP Laryngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1800038* View details Winning BidN/A Lot 17 Pentax FHY-10RBS Hysteroscope with BS-LL1 Mini Light Source in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *G110253* View details StatusUnsold Lot 18 Karl Storz Model 11278VS Urethroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details Winning BidN/A Lot 19 Olympus URF-P5 Urethroscope in Case - Engineer's Report : Optical System - 18 Broken Fibers, Angulation - Strained, Insertion Tube - No Bending Rubber, Light Transmission - No Fault Found, Channels - No Fault Found, Leakc Check - Untested Due to Missing Bending Rubber *2600441* View details Winning BidN/A Lot 20 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, ANgulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700478* View details Winning BidN/A Lot 21 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - This is a Sterrad Ready Plus Model *W47762* View details Winning BidN/A Lot 22 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W704216* View details StatusUnsold Lot 23 Pentax EG-2970K Video Gastroscope in Case - Engineer's Report : Optical System - Interference on Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Minor Leak View details Winning BidN/A Lot 24 Pentax EC-380LP Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *E01199* View details Winning BidN/A Lot 25 Pentax EG-3830UT Ultrasound Gastroscope in Case - Engineer's Report : Optical System - Fully Functional, Angulation - No Fault Found, Insertion Tube, No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *E110021* View details Winning BidN/A Lot 26 Pentax EC-3870LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details StatusUnsold Lot 27 Riester Model 3900 Pharyngoscope with Light Guide Tube in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *543848* View details Winning BidN/A Lot 28 Pentax EG3630U Ultrasound Gastroscope in Case - Engineer's Report : Optical System - Fully Functional, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *E110267* View details Winning BidN/A Lot 29 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink, Light Transmission - No Fault Found, Leak Check - No Fault Found *SN 2931693* View details Winning BidN/A Lot 30 Pentax ES-3870K Video Sigmoidoscope- Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *SN A120033* View details StatusUnsold Lot 31 Olympus CHF-B20 Duodenoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, 2 Meter Long Clear Silicon Specialist Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details StatusUnsold Lot 32 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - Blur on Image and Focus Fault, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak Present *W804839* View details Winning BidN/A Lot 33 Olympus BF-200 Video Bronchoscope- Engineer's Report : Optical System - No Fault Found, Angulation - Strained, Insertion Tube - Bending Section Rubber Split / Kinked, Light Transmission - No Fault Found, Leak Check - Leaking *SN 2300070* View details Winning BidN/A Lot 34 Olympus CYF-4 Cystoscope - Engineer's Report : Optical System - 5 Broken Fibers and Slight Stain, Angulation - No Fault Found, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak Present *W102709* View details StatusUnsold Lot 35 Olympus HYF Type P Hysterscope - Engineer's Report : Optical System - Excessive Broken Fibres, Angulation - Severely Crushed, Insertion Tube - Perished, Light Transmission - Poor, Leak Check - Excessive *SN 1100534* View details StatusUnsold Lot 36 Pentax ECY-1570 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *J110094* View details StatusUnsold Lot 37 Olympus SIF-230 Video Enteroscope- Engineer's Report : Optical System - No Fault Found, Angulation - Slightly Distorted, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Leak Check - No Fault Found *SN 170T215* View details Winning BidN/A Lot 38 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault FOund, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *W901717* View details Winning BidN/A Lot 39 Olympus LF-GP Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indentations, Light Transmission - No Fault Found, Channels - No Fault Found *W101169* View details Winning BidN/A Lot 40 Olympus ENF P4 Pharyngoscope- Engineer's Report : Optical System - Excessive Broken Fibres, Angulation - Up Inoperative, Insertion Tube - Badly Kinked, Light Transmission - Poor, Leak Check - Leaking *SN 1420058* View details Winning BidN/A Lot 41 Pentax FI-13RBS Laryngoscope - Engineer's Report : Optical System - No Broken Fibres, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *SN G110156* View details Winning BidN/A Lot 42 Olympus HYF Type P Hysterscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W600655* View details Winning BidN/A Lot 43 Job Lot Including 3 x 260 Series Twin Stack Trolley Connectors and 1 x Olympus MAJ Water Bottle *Cap / Lead Needs Reaffixing* View details Winning BidN/A Lot 44 Job Lot Including 1 x Olympus MAJ-1536 260 Series Endoscope with Tray and 1 x Olympus MAJ-2146 Sliding Tray for Endoscope Keyboard View details Winning BidN/A Lot 45 1 x Olympus Evis Lucera CV-260SL Processor and 1 x Olympus Evis Lucera CLV-260SL Light Source (Both Power Up and Fully Function Checked) View details Winning BidN/A Lot 46 1 x Olympus Evis Lucera CV-260SL Processor and 1 x Olympus Evis Lucera CLV-260SL Light Source (Both Power Up and Fully Function Checked) View details Winning BidN/A Lot 47 1 x Olympus Evis Lucera CV-260SL Processor (Powers Up and Fully Function Checked) and 1 x Olympus Evis Lucera CLV-260SL Light Source (Powers Up, No Lights on Faceplate, Damaged Casing - See Photo) View details Winning BidN/A Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next