September 2021 Endoscopy Equipment 22/09/2021 11:00 AM BST - 28/09/2021 2:00 PM BST View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-53 of 53. Previous|1|Next Image Lot # Item Title Time Left Your Bids 1 Olympus OEV191H Monitor (Powers Up) 1 Winning BidN/AStatusSold View details 2 Karl Storz Image 1 S3 Camera Head *FA750452-H* 1 Winning BidN/AStatusSold View details 3 ConMed IM4120 Autoclave True HD Camera Head *73543* 1 Winning BidN/AStatusSold View details 4 ConMed IM4120 Autoclave True HD Camera Head *73528* 1 Winning BidN/AStatusSold View details 5 R Wolf 8703.524 Ureteroscope *Clear View* 1 Winning BidN/AStatusSold View details 6 Karl Storz 27050D Working Element 1 Winning BidN/AStatusSold View details 7 R.Wolf 8708.534 Offset Ureteroscope with R.Wolf Light Cable in Case (Clear Image) 1 Winning BidN/AStatusSold View details 8 Karl Storz Resectoscope Set Including 1 x 27005 BA Hopkins II 30 Degree Telescope, 1 x 27051A Inner Sheath, 1 x 27040 Outer Sheath, 1 x 27048 CO Obturator, 1 x Light Lead and 1 x Scope Cover (Clear Image) 1 Winning BidN/AStatusSold View details 9 Stryker Ref 5400-50 Core Powered Instrument Driver *HW ID - Rev 1.3, Software - 0590-090-900 7.0_Build_6* with Footswitch (Powers Up) *0703100373* 1 Winning BidN/AStatusSold View details 10 1 x Olympus A2622 Outer Sheath with A70951A Inner Deflecting Obturator 1 Winning BidN/AStatusSold View details 11 Pentax EC-3890Li Video Colonoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A112030* (LP) 1 Winning BidN/AStatusSold View details 12 Pentax EG-2990i Video Gastroscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A116205* (LP) 1 Winning BidN/AStatusSold View details 13 Pentax EG-2990i Video Gastroscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A113876* (LP) 1 Winning BidN/AStatusSold View details 14 Pentax EG-2990i Video Gastroscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A113878* (LP) 1 Winning BidN/AStatusSold View details 15 Pentax EG-2990i Video Gastroscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A113879* (LP) 1 Winning BidN/AStatusSold View details 16 Pentax EC-3890Fi Video Colonoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A111073* (LP) 1 Winning BidN/AStatusSold View details 17 Pentax EG-2990i Video Gastroscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A113877* (LP) 1 Winning BidN/AStatusSold View details 18 Pentax EC-3490Li Video Colonoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A110741* (LP) 1 Winning BidN/AStatusSold View details 19 Pentax EC-3490Li Video Colonoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A110738* (LP) 1 Winning BidN/AStatusSold View details 20 Pentax EC-3490Li Video Colonoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Light Transmission - No Fault Found, Channels - Untested, Leak Check - No Fault Found *A110731* (LP) 1 Winning BidN/AStatusSold View details 21 MSI 454555 Rhinolaryngoscope with Light Guide Tube and Leak Tester in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - Unable to Inflate *503430NP* 1 Winning BidN/AStatusSold View details 22 Pentax FNL-7RP3 Rhinolaryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Slightly Strained, Minor Crush, Light Transmission - No Fault Found, Leak Check - Bending Section Rubber Leaking *H114624* 1 Winning BidN/AStatusSold View details 23 Pentax FB-18BS Bronchoscope with Mains Mini Light Source (Tested Working) and Leak Tested in Case - Engineer's Report : Optical System - Approx. 6 Broken Fibers and Dirt Particles, Angulation - Strained, Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A01127* 1 Winning BidN/AStatusSold View details 24 Olympus OSF-3 Sigmoidoscope in Case - Engineer's Report : Optical System - 50+ Broken Fibers, Misty View and Condensation, Angulation - Not Reaching Specification, Insertion Tube - Badly Worn, Light Transmission - 50% Light Loss, Channels - No Fault Found, Leak Check - No Fault Found *2103674* 1 Winning BidN/AStatusSold View details 25 Olympus CF-P10S Sigmoidoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Mist Image and Condensation, Angulation - Play in Controls, Insertion Tube - Hood Missing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2511210* 1 Winning BidN/AStatusSold View details 26 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - Unable to Check for Broken Fibers Due to Blurred and Distorted Image, Angulation - Strained, Insertion Tube - Twisted and Split, Light Transmission - No Fault Found, Channels - Unable to Check, Leak Check - Leaking Tube *W405224* 1 StatusUnsold View details 27 Olympus ENF-P4 Rhinolaryngoscope in Case - Engineer's Report : Optical System - 10+ Broken Fibers, Dirt Particles and Mask Upside Down, Angulation - Click in Action, Insertion Tube - Badly Wrinkled, Light Transmission - OK, Leak Check - Unable to Check, Other Comments, Control Body Sleeve Missing with Split Present, Plug Shell Missing 1 Winning BidN/AStatusSold View details 28 Olympus MH-977 Pigtail Connector 1 Winning BidN/AStatusSold View details 29 Karl Storz Telecam 20210130 NTSC Camera Head 1 Winning BidN/AStatusSold View details 30 Olympus OTV-S4 Camera Head with 1 x AR-TD2 Coupler and AR-SX12E Coupler 1 Winning BidN/AStatusSold View details 31 Stryker Stack System Including Stryker VisionPro LED Display (Untested Due to No Power Supply), 1 x Stryker SDC Ultra HD Information Management System *Version - 7.0G* (Powers Up with Application Critical Error), Stryker L9000 LED Light Source, Stryker 1288 HD High Definition Camera Control Unit and Stryker Pneumo Sure High Flow Insufflator (All Power Up) *FS0188717 / FS0108547 / FS0188731 / FS0108546 / FS0108553* **IR147** 1 Winning BidN/AStatusSold View details 32 Fujinon EVE E4000 Light Source and 2 x Fujinon EVE E400 Processor Units (All Power Up) 1 Winning BidN/AStatusSold View details 33 1 x Olympus OTV-F Camera Control Unit and 1 x Olympus OTV-F Camera Connector Unit (Both Power Up) 1 Winning BidN/AStatusSold View details 34 Olympus OTV-SX2 Camera with AR-SX12E Coupler in Case 1 Winning BidN/AStatusSold View details 35 Stryker Stack Trolley Including Stryker Vision Elect HDTV Surgical Viewing Monitor,Stryker Pneumo Sure High Flow Insufflator,Stryker SDC Ultra HD Information Management System *Hard Drive Removed*,Stryker 1288 HD Camera Control Unit,Stryker 1288 HD Camera Head,Stryker L9000 LED Light Source Unit and Light Source Cable (Powers Up) *IR152* 1 Winning BidN/AStatusSold View details 36 Stack Trolley Including Sony Trinitron Monitor,Storz Xenon Nova 201315 20 Light Source Unit,Storz Telecam SL Pal 202120 20 Camera Control Unit,Storz 20212031 Camera Head,Storz AIDA Control Neo 200461 20 Unit and Sony Color Video Printer (Powers Up) 1 Winning BidN/AStatusSold View details 38 Olympus Stack Trolley Including Olympus Visera OTV-S7 Camera Control Unit,Olympus OTV-S7 Camera Head,Olympus OES CLV-S30 Light Source Unit and Connector Cables (Powers Up) 1 Winning BidN/AStatusSold View details 39 Olympus Compact Stack Trolley Including Sony LCD Monitor,Olympus OTV-SI Digital Processor,Olympus OTV-S7 Camera Head,Medicapture MediCap USB200 Unit,Light Source Cable and Sony Color Video Printer UP-25MD (Powers Up) * SN 7325567 / 3002785 / 7356114 * 1 Winning BidN/AStatusSold View details 40 2 x Olympus Stack Trolleys Including Olympus OEV191H Monitor,Olympus Evis Lucera CV-260 Processor,Olympus Evis Lucera CLV-260 Processor/Light Source Unit,Olympus MAJ-1154 Pigtail Connector,Sony Color Video Printer UP-25MD,Olympus Keyboard and Connector Cables (Powers Up) * Asset No FS 0108606 / FS 0111548 / FS 0111549 / FS 0111555 * 1 Winning BidN/AStatusSold View details 41 Job Lot Including 1 x Olympus OTV-SC Digital Signal Processing Camera Control Unit, 1 x Olympus OES CLV-S20 Light Source, 1 x Olympus OES OTV-S6 Advanced Digital Multi Processor and 1 x Olympus OES OTV-SX2 Camera Control Unit (All Power Up) 1 Winning BidN/AStatusSold View details 42 Job Lot Including 1 x Stryker Q-5000 Light Source and 1 x Stryker 888i Medical Video Digital Camera Control Unit with Camera (Both Power Up) 1 Winning BidN/AStatusSold View details 43 Job Lot Including 1 x Stryker Q-5000 Light Source and 1 x Stryker 888i Medical Video Digital Camera Control Unit with Camera (Both Power Up) 1 Winning BidN/AStatusSold View details 44 Job Lot Including 1 x Stryker Q-5000 Light Source (Damaged Button - See Photo) and 1 x Stryker High Flow Insufflator (Both Power Up) 1 Winning BidN/AStatusSold View details 45 Job Lot Including 1 x Pentax LH-150PC Light Source and 1 x DePuy XL-300 M Light Source (Both Power Up with Good Bulbs) 1 Winning BidN/AStatusSold View details 46 Karl Storz 11272 Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Tube Sleeving Torn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Bending Section Rubber *2250197* 1 Winning BidN/AStatusSold View details 47 Olympus TJF-260V Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800656* 1 Winning BidN/AStatusSold View details 48 Olympus TJF-260V Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2001234* 1 Winning BidN/AStatusSold View details 49 Karl Storz 11101SP2 Pharyngoscope in Case - Engineer's Report : Optical System - 4 x Broken Fibers, Angulation - Seized, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Leak Check - Unable to Check Due to No Bending Section Rubber *2824034* 1 Winning BidN/AStatusSold View details 50 Fujinon EG-530FP Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak from Umbilical Cord *314A128* 1 Winning BidN/AStatusSold View details 51 Fujinon ED-530XT8 Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *103A591* 1 Winning BidN/AStatusSold View details 52 Fujinon ED-530XT8 Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *103A584* 1 Winning BidN/AStatusSold View details 53 Fujinon ED-530XT8 Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leakage Evident from Case Cover *103A581* 1 Winning BidN/AStatusSold View details 54 Fujinon ED-530XT8 Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Light Scuffing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *103A575* 1 Winning BidN/AStatusSold View details Items per page 102550100 Previous|1|Next Previous 1 Next