July 2021 Endoscopy 22/07/2021 12:45 PM BST - 29/07/2021 1:48 PM BST View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-49 of 49. Previous|1|Next Image Lot # Item Title Time Left Your Bids 1 Olympus TJF-260V Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2201795* 1 Winning BidN/AStatusSold View details 2 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800165* 1 Winning BidN/AStatusSold View details 3 Olympus BF-260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked / Crushed at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1300242* 1 Winning BidN/AStatusSold View details 4 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - 2 Broken Fibers and Minor Dirt Specks Present, Angulation - No Fault Found, Insertion Tube - Grip Split, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W602862* 1 Winning BidN/AStatusSold View details 5 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W602794* 1 Winning BidN/AStatusSold View details 6 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - Minor Hairline Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W602863* 1 Winning BidN/AStatusSold View details 7 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Minor Wear, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W9062X6* 1 Winning BidN/AStatusSold View details 8 Olympus BF-XP40 Bronchoscope in Case - Engineer's Report : Optical System - 30+ Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush Marks and Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Excessive Leak Present *1200565* 1 Winning BidN/AStatusSold View details 9 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Scratching, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Minor Leak Present *2033676* 1 Winning BidN/AStatusSold View details 10 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bite/Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930925* 1 Winning BidN/AStatusSold View details 11 Olympus MH-908 Ultrasound Scope / Probe in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Untested, Channels - Untested, Leak Check - No Fault Found *1410185* 1 Winning BidN/AStatusSold View details 12 Olympus ENF-GP Laryngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Kink at Grip, Light Transmission - No Fault Found, Leak Check - No Fault Found *W204034* 1 Winning BidN/AStatusSold View details 13 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - 1 Broken Fiber and Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W7104407* 1 Winning BidN/AStatusSold View details 14 Olympus ENF-GP Laryngoscope in Case - Engineer's Report : Optical System - 16 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found, Other Comments - Body Worn *1402143* 1 Winning BidN/AStatusSold View details 15 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W602838* 1 Winning BidN/AStatusSold View details 16 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W602797* 1 Winning BidN/AStatusSold View details 17 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900462* 1 Winning BidN/AStatusSold View details 18 Olympus TJF-260V Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2001301* 1 Winning BidN/AStatusSold View details 19 Olympus MH-908 Ultrasound Scope / Probe in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Untested, Channels - Untested, Leak Check - No Fault Found *1610204* 1 Winning BidN/AStatusSold View details 20 Olympus ENF-GP Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink at Bending Section, Bending Section Rubber Perforated, Light Transmission - No Fault Found, Leak Check - Leak at Bending Section Rubber *W204023* 1 Winning BidN/AStatusSold View details 21 Olympus ENF-P3 Laryngoscope in Case - Engineer's Report : Optical System - 4 Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Worn, Bending Section Rubber Stretched and Leaking, Light Transmission - No Fault Found, Leak Check - Bending Section Rubber Leaking *2103086* 1 Winning BidN/AStatusSold View details 22 Pentax FB-15BS Bronchoscope - Engineer's Report : Optical System - Small Cluster of Broken Fibers / Dirt on Mask Edge, Angulation - No Fault Found, Insertion Tube - Crush Mark Visible, Light Transmission - No Fault Found, Leak Check - No Fault Found *A01533* 1 Winning BidN/AStatusSold View details 23 Pentax FCY-15RBS Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Wear, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Will Not Inflate *A110080* 1 Winning BidN/AStatusSold View details 24 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - Multiple Broken Fibers, Angulation - No Fault Found, Insertion Tube - Severely Crushed, Light Transmission - No Fault Found *2814237* 1 Winning BidN/AStatusSold View details 25 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - 10 Broken Fibers, Angulation - Not Reaching Specification, Bending Section Fault in Link, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *2814203* 1 Winning BidN/AStatusSold View details 26 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush Mark Present, Light Transmission - No Fault Found *2814269* 1 Winning BidN/AStatusSold View details 27 Karl Storz 11101RP2 Pharyngoscope in Case - Engineer's Report : Optical System - Multiple Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *2814371* 1 Winning BidN/AStatusSold View details 28 Karl Storz 11004BC1 Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Strained, Insertion Tube - No Fault Fond, Light Transmission - No Fault Found *2185980* 1 Winning BidN/AStatusSold View details 29 Olympus LF-2 Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1820046* 1 Winning BidN/AStatusSold View details 30 Pentax FB-15RBS Bronchoscope - Engineer's Report : Optical System - No Fault Found, Loose Optics, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A111575* 1 Winning BidN/AStatusSold View details 31 Karl Storz 11302BDZ Laryngoscope - Engineer's Report : Optical System - Multiple Broken Fibers, Angulation - No Fault Found, Insertion Tube - Severely Crushed, Light Transmission - No Fault Found, Channels - No Fault Found *2207177* 1 Winning BidN/AStatusSold View details 32 Karl Storz 11302BDZ Laryngoscope - Engineer's Report : Optical System - 16 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Bad Crush Marks, Light Transmission - No Fault Found, Channels - No Fault Found *2183677* 1 Winning BidN/AStatusSold View details 33 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak Present *2134125* 1 Winning BidN/AStatusSold View details 34 Karl Storz 11302BDZ Laryngoscope in Case - Engineer's Report : Optical System - Stain on Mask Edge, Angulation - No Fault Found, Insertion Tube - Badly Crushed, Light Transmission - No Fault Found, Channels - No Fault Found *2239266* (RI) 1 Winning BidN/AStatusSold View details 35 Karl Storz 11576 Imaging Probe - Engineer's Report : Optical System - Present - Unable to Check Fully, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *766940* 1 Winning BidN/AStatusSold View details 36 Olympus OSF-2 Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - L/R Brake Slipping, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600499* 1 Winning BidN/AStatusSold View details 37 Olympus CHF-10 Choledocoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Sleeving Perished, Light Transmission - No Fault Found, Channels - No Fault Found *1810740* 1 Winning BidN/AStatusSold View details 38 Karl Storz 10331 B1 0 Degree Rigid Scope in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *761703* 1 Winning BidN/AStatusSold View details 39 Karl Storz 10331 B1 0 Degree Rigid Scope in Case - Engineer's Report : Optical System - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *1129135* 1 Winning BidN/AStatusSold View details 40 Karl Storz 11101RPZ Pharyngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Missing and Tube Worn, Light Transmission - No Fault Found *2814783* 1 Winning BidN/AStatusSold View details 41 Richard Wolf Choledocoscope - Engineer's Report : Optical System - Large Dirt Particles Obscuring Image, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found *190670* 1 Winning BidN/AStatusSold View details 42 Richard Wolf 7305 Choledocoscope - Engineer's Report : Optical System - 11 Broken Fibers and Some Grey Fibers, Angulation - Strained, Insertion Tube - Badly Kinked, Light Transmission - 50% Loss *209076* 1 StatusUnsold View details 43 Fentex 700700FX Pharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 44 Olympus CYF-4 Cystoscope in Carry Case Engineer's Report : Optics - 1 Broken Fibre, Angulation - Ok, Patient Tube - Ok, Light Transmission - 80% Loss, Channel System - Ok, Leak Check- Ok *S/N W203958* *Mfd 1994* 1 Winning BidN/AStatusSold View details 45 Olympus CYF-5 Video Cystoscope In Carry Case Engineer's Report : Optics - 10 Broken Fibres, Angulation - Ok , Patient Tube - Ok , Light Transmission - Ok, Channel System - Ok, Leak Check- Valve Blocked *S/N 2901049* *Mfd 2009* 1 Winning BidN/AStatusSold View details 46 Olympus MH-908 Esophageal Ultrasonic Probe *1710210* 1 Winning BidN/AStatusSold View details 47 Pentax ES-3870K Sigmoidoscope in Case - Engineer's Report : Optical System - Untested Due to No Processor, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested *A120026* 1 StatusUnsold View details 48 Pentax ECY-1570 Video Colonoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Strained, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - Unable to Check *A110025* 1 Winning BidN/AStatusSold View details 49 Pentax ES-3870K Sigmoidoscope in Case - Engineer's Report : Optical System - Untested Due to No Processor, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested *A120031* 1 StatusUnsold View details Items per page 102550100 Previous|1|Next Previous 1 Next