May 2021 Endoscopy 17/05/2021 12:00 PM BST - 27/05/2021 3:26 PM BST View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 175. Previous|12|Next Image Lot # Item Title Time Left Your Bids 1 Olympus CYF-3 Fibre Optic Cystoscope in Case - Engineer's Report : Optical System - Badly Stained, Angulation - Strained, Insertion Tube - Worn, Light Transmission - Ok, Channels - Ok, Leak Check - Ok *SN W703741* *Mfd 1987* 1 StatusUnsold View details 2 Olympus PCF-P240AL Video Colonoscope in Case - Engineer's Report : Optical System - Ok, Angulation - Not Reaching Specification, to be Adjusted , Insertion Tube - Ok, Light Transmission - Ok , Channels - Ok, Leak Check - Ok, Accessories 1 x Waterproof Cap *SN 2300128* 1 Winning BidN/AStatusSold View details 3 Olympus ENF Type L3 Flexible Fibre Rhinolaryngoscope in Case - Engineer's Report : Optical System - Five Broken Fibre, Angulation - Brake will Not Release, Insertion Tube - Worn, Light Transmission - Ok, Channels - Ok, Leak Check - Leaking *SN 1110116* *Mfd 1991* (Body Badly Squashed) 1 Winning BidN/AStatusUnsold View details 4 Olympus Type CYF-240 Video Cystoscope in Case- Engineer's Report : Optical System - No Image, Angulation - Strained Not Reaching Specification, Insertion Tube - Crush Marks , Light Transmission - Ok , Channels - Ok, Leak Check - Excessive Leak 1 StatusUnsold View details 5 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained, Not Reaching Specification, Insertion Tube - No Fault Found, Light Transmission - No Fault FOund, Channels - No Fault Found, Included Valves, Leak Check - No Fault Found *2800240* 1 Winning BidN/AStatusSold View details 6 Olympus BT-IT240 Video Bronchoscope in Case - Engineer's Report : Optical System - OK, Angulation - OK, Insertion Tube -Minor Indentations, Light Transmission - OK, Channels -OK , Leak Check - OK *S/N 1130815* 1 StatusUnsold View details 7 Olympus GIF H260 Video Gastroscope in Case - Engineer's Report : Optical System - OK, Angulation - OK, Insertion Tube - B.S.R. Cement Needs Refreshing, Light Transmission - OK, Channels - No Fault Found Including Valves , Leak Check - OK *S/N 2040678* 1 Winning BidN/AStatusSold View details 8 Olympus ENF Type L3 in Case - Engineer's Report : Optical System - No Broken Fibres, Angulation - OK, Insertion Tube - Torn B.S.R., Light Transmission - OK, Channels -OK , Leak Check - Leak from Tube *S/N 1410181* 1 Winning BidN/AStatusSold View details 9 Olympus BF Type P240 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1940265* 1 Winning BidN/AStatusSold View details 10 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2745449* 1 Winning BidN/AStatusSold View details 11 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Requires Adjustment. Insertion Tube - Bending Section Rubber Glue Requires Refreshing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2011452* 1 Winning BidN/AStatusSold View details 12 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2745459* 1 Winning BidN/AStatusSold View details 13 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Minor Kink Present, Channels - No Fault Found, Leak Check - No Fault Found *2141106* 1 Winning BidN/AStatusSold View details 14 Pentax ES-3870K Sigmoidoscope in Case - Engineer's Report : Optical System - Untested Due to No Processor, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested *A120026* 1 StatusUnsold View details 15 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2644161* 1 Winning BidN/AStatusSold View details 16 Olympus GIF-XP260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2923523* 1 Winning BidN/AStatusSold View details 17 Riester 3900 Pharyngoscope in Case - Engineer's Report : Optical System - 0 Broken Fibers, No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *536089* 1 Winning BidN/AStatusSold View details 18 Accutronic EF-N Pharyngoscope with Light Guide Cable in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 19 Olympus LF-TP Laryngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Scratches Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Severe Leak at Body *W700364* 1 Winning BidN/AStatusSold View details 20 Riester 3900 Pharyngoscope in Case - Engineer's Report : Optical System - 0 Broken Fibers, No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *541258* 1 Winning BidN/AStatusSold View details 21 Atmos 950.0243 Pharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber and Misty View, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *406430* 1 Winning BidN/AStatusSold View details 22 Olympus URF Type P5 Urethroscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - Severely Strained Bending Section, Insertion Tube - Perishing at Proximal End, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking Tube *2902185* 1 Winning BidN/AStatusSold View details 23 Pentax EC-3840L Video Colonoscope in Case - Engineer's Report : Optical System - Untested Due to No Processor, Angulation - No Fault Found, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - Untested, Leak Check - Untested *A10255* 1 StatusUnsold View details 24 LSVP E-22VGS 99X17 1.6 Metre Scope in Case - Engineers Report : Optical System - Excessive Broken Fibers and Severe Fluid Stain, Angulation - No Fault Found, Insertion Tube - Collapsed, Light Transmission - Poor, Channels - A/W Valve Broken, Leak Check - Untested 1 Winning BidN/AStatusSold View details 25 Fujinon FR-120OF Pharyngoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *B025* 1 StatusUnsold View details 26 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Slightly Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found (ID Label Removed - See Photo) *348K905* 1 Winning BidN/AStatusSold View details 27 Fujinon EG-530 Slim Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube- Kinks and Indentations Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found (ID Label Removed - See Photo) *1G366K058* 1 Winning BidN/AStatusSold View details 28 Olympus GIF-XP260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2310880* 1 Winning BidN/AStatusSold View details 29 Olympus GIF-XP260 Video Gastroscope in Case - Engineer's Report : Optical System - Slightly Misty, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2723364* 1 Winning BidN/AStatusSold View details 30 Olympus CHF-P10 Choledocoscope - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - Severely Strained, Insertion Tube - Severley Rucked and Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking *2701689* 1 StatusUnsold View details 31 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2830420* 1 Winning BidN/AStatusSold View details 32 Olympus BF-P200 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Down Angulation Inoperative, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak Evident *2510884* 1 StatusUnsold View details 33 Olympus GIF-1T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2903458* 1 Winning BidN/AStatusSold View details 34 Olympus GIF-IT240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930044* 1 Winning BidN/AStatusSold View details 35 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Included Valves, Leak Check - No Fault Found *2100154** 1 Winning BidN/AStatusSold View details 36 Olympus JF-1T20 Duodenoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber and Fluid Stain Present, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found (Raiser Control Missing) *2215474* 1 Winning BidN/AStatusSold View details 37 Olympus BF-1T200 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Down Angulation Inoperative, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2510615* 1 Winning BidN/AStatusSold View details 38 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Minor Leak Present *W203961* 1 Winning BidN/AStatusSold View details 39 Olympus GIF-2T10 Gastroscope in Case - Engineer's Report : Optical System - 3 Broken Fibers and Fluid Stain Present, Angulation - Not Reaching Specification and Badly Strained, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Leak Check - No Fault Found *2032115* 1 Winning BidN/AStatusSold View details 40 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2530285* 1 Winning BidN/AStatusSold View details 41 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Indentations Presents, Light Transmission - No Fault Found, Leak Check - No Fault Found *H114983* 1 Winning BidN/AStatusSold View details 42 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Presents, Light Transmission - No Fault Found, Leak Check - No Fault Found *H114680* 1 Winning BidN/AStatusSold View details 43 Olympus GIF-1T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Bending Section Strained, L/R Brake Faulty, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930448* 1 StatusUnsold View details 44 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - 30 Broken Fibers, Angulation - Strained, Insertion Tube - Bending Section Rubber Rucked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2901065* 1 Winning BidN/AStatusSold View details 45 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W405445* 1 Winning BidN/AStatusSold View details 46 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers and Focus Fault, Angulation - Not Reaching Specification, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - Excessive Leak at Eyepiece *2041942* 1 Winning BidN/AStatusSold View details 47 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2900650* 1 StatusUnsold View details 48 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2668573* 1 Winning BidN/AStatusSold View details 49 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber and Fluid in Optics, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Torn, Leak Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Bending Section Rubber Leaking *2668602* 1 Winning BidN/AStatusSold View details 50 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 5 Broken Fibers and Misty View, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking (S) *W102101* 1 Winning BidN/AStatusSold View details 51 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111772* 1 Winning BidN/AStatusSold View details 52 Vision Sciences ENT-200 Pharyngoscope in Case - Engineer's Report : Optical System - 4 Broken Fibers and Loose Eyepiece, Angulation - No Fault Found, Insertion Tube - Collapsed, Torn and Severed, Light Transmission - 20% Loss, Leak Check - Leak Present, Other Comments - Light Guide Tube Perishing 1 Winning BidN/AStatusSold View details 53 Acutronic Laryngoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked and Bending Section Rubber Missing, Light Transmission - No Fault Found 1 Winning BidN/AStatusSold View details 54 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - 0 Broken Fibers, Minor Mark, Angulation - No Fault Found, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2668548* 1 Winning BidN/AStatusSold View details 55 Olympus GIF-XQ20 Gastroscope in Case - Engineer's Report : Optical System - Approximately 200 Broken Fibers and Severe Fluid Stain, Angulation - Not Reaching Specification, Insertion Tube - Severely Crushed, Light Transmission - Poor, Channels - No Fault Found, Leak Check - Leaking *2802692* 1 Winning BidN/AStatusSold View details 56 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W602955* 1 Winning BidN/AStatusSold View details 57 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers and Severe Fluid Stain, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking *W405440* 1 Winning BidN/AStatusSold View details 58 Olympus CYF-3 Cystoscope in Case - Engineer's Report : Optical System - Approximately 200 Broken Fibers, Angulation - Not Reaching Specification, Insertion Tube - Minor Kinks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking *W400033* 1 Winning BidN/AStatusSold View details 59 Olympus CF-P20L Colonoscope in Case - Engineer's Report : Optical System - Approximately 120 Broken Fibers and Bad Fluid Stain Present, Angulation - Not Reaching Specification, Insertion Tube - Split, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking *2910407* 1 Winning BidN/AStatusSold View details 60 Olympus CF-200HL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600051* 1 Winning BidN/AStatusSold View details 61 Olympus CYF-5 Cystoscope with Light Guide Cable in Case - Engineer's Report : Optical System - 10 Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W602594* 1 Winning BidN/AStatusSold View details 62 Olympus GIF-2T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2530807* 1 Winning BidN/AStatusSold View details 63 Olympus CF-P10S Sigmoidoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber and Misty View, Angulation - No Fault Found, Insertion Tube, No Fault Found, Other Comments - Distal Hood Missing *2511210* 1 StatusUnsold View details 64 Olympus CF-1TS2 Sigmoidoscope in Case - Engineer's Report : Optical System - 1 Broken Fiber, Angulation - Play in Controls, Insertion Tube - Worn, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Untested Due to Non-Submersible Scope *111492* 1 StatusUnsold View details 65 Olympus GIF-2T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Requires Adjustment, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2630834* 1 Winning BidN/AStatusSold View details 66 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulatiom - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2544015* 1 Winning BidN/AStatusSold View details 67 Olympus PCF-H190DI Video Colonoscope with Valves in Case - Engineer's Report : Optical System - Untested Due to No Processor, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check, Leak Check - No Fault Found *2830424* 1 Winning BidN/AStatusSold View details 68 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Bending Section Rubber Cement Requires Refreshing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2532886* 1 Winning BidN/AStatusSold View details 69 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2123210* 1 Winning BidN/AStatusSold View details 70 Olympus GIF-Q240Z Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Bending Section Rubber Cement Requires Refreshing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Excessive Leak Present *2400302* 1 Winning BidN/AStatusSold View details 71 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2745461* 1 Winning BidN/AStatusSold View details 72 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2856641* 1 Winning BidN/AStatusSold View details 73 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Jump in L/R Brake, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300116* 1 StatusUnsold View details 74 Olympus TJF-260V Duodenoscope in Case - Engineer's Report : Optical System - Minor Shadow Mark on Centre Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2800562* 1 Winning BidN/AStatusSold View details 75 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2544025* 1 Winning BidN/AStatusSold View details 76 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - 2 Broken Fibers and Minor Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - I.D. Badge Worn Away *W147613* 1 StatusUnsold View details 77 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *7856635* 1 Winning BidN/AStatusSold View details 78 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600209* 1 Winning BidN/AStatusSold View details 79 Olympus JF-240 Video Duodenoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2230960* 1 Winning BidN/AStatusSold View details 80 Olympus GIF-Q240Z Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Bending Section Rubber Cement Requires Refreshing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2100144* 1 Winning BidN/AStatusSold View details 81 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300099* 1 Winning BidN/AStatusSold View details 82 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - L/R Brake Jumping, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600214* 1 StatusUnsold View details 83 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2411186* 1 Winning BidN/AStatusSold View details 84 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2856796* 1 Winning BidN/AStatusSold View details 85 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300104* 1 Winning BidN/AStatusSold View details 86 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - L/R Brake Slight Jump, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300106* 1 StatusUnsold View details 87 Olympus PCF-240S Video Sigmoidoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300117* 1 StatusUnsold View details 88 Olympus GIF-Q240Z Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Bending Section Rubber Cement Requires Refreshing, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2600486* 1 Winning BidN/AStatusSold View details 89 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found. Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2510238* 1 Winning BidN/AStatusSold View details 90 Olympus CYF-5 Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W247986* 1 Winning BidN/AStatusSold View details 91 Olympus BF-1T240 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1030642* 1 Winning BidN/AStatusSold View details 92 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault FOund, Channels - No Fault Found, Leak Check - No Fault Found *2040671* 1 Winning BidN/AStatusSold View details 93 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *290B088* 1 Winning BidN/AStatusSold View details 94 Fujinon EC-410HL Video Colonoscope in Case - Engineer's Report : Optical System - No Image, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *164D040* 1 StatusUnsold View details 95 Pentax FNL-10RP3 Laryngoscope in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *114233* 1 Winning BidN/AStatusSold View details 96 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *290B078** 1 Winning BidN/AStatusSold View details 97 Pentax EG-2970K Video Gastroscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Unable to Check *A121933* 1 Winning BidN/AStatusSold View details 98 Pentax ECY-1570 Video Colonoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Strained, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - Unable to Check *A110025* 1 StatusUnsold View details 100 Pentax ES-3870K Sigmoidoscope in Case - Engineer's Report : Optical System - Untested Due to No Processor, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Untested *A120031* 1 StatusUnsold View details 101 Pentax FNL-10RBS Laryngoscope in Case - Engineer's Report : Optical System - Approximately 200 Broken Fibers, Angulation - Severe Crush in Bending Section, Insertion Tube - Severe Crush in Bending Section, Light Transmission - 100% Light Loss *G111423* 1 Winning BidN/AStatusSold View details Items per page 102550100 Previous|12|Next Previous 12 Next