BRITISH MEDICAL AUCTIONS April 2021 Endoscopy Equipment (#340) 09/04/2021 6:45 PM BST - 16/04/2021 2:01 PM BST CLOSED Starts Ending 16/04/2021 1:00 PM BST Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-69 of 69. Previous|1|Next Lot 1 Olympus LF-GP Laryngoscope Fiber Intubation Scope in Case - Engineer's Report : Optical System - No Broken Fibres , Angulation - Ok- Insertion Tube - Ok, Light Transmission - Ok, Channels - Ok Leak Check - Ok, 1 x Olympus WA91502A Portable Light Source Unit (Powers Up) *S/N 2620926 Mfd 2006* View details Winning BidN/A Lot 2 Olympus CF-240AL Video Colonoscope in Case - Engineer's Report : Optical System - Ok , Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - Ok, Light Transmission - Ok , Channels - Ok, Leak Check - Ok *S/N2210151 Mfd 2002* View details Winning BidN/A Lot 3 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System -Ok , Angulation - Ok, Insertion Tube - Ok , Light Transmission - Ok, Channels - Ok,Leak Check - Ok *S/N 2813004 Mfd 1998* View details Winning BidN/A Lot 4 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System -Ok , Angulation - Ok, Insertion Tube - Indentations Visible , Light Transmission - Ok, Channels - Ok,Leak Check - Ok *S/N 2913260 Mfd 1999* View details Winning BidN/A Lot 5 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System -Ok , Angulation - Ok, Insertion Tube - Ok, Light Transmission - Ok, Channels - Ok,Leak Check - Ok *S/N 2235272 Mfd 2002* View details Winning BidN/A Lot 6 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System -Ok , Angulation - Ok, Insertion Tube - Ok, Light Transmission - Ok, Channels - Ok,Leak Check - Intermittent Leak *S/N 2336985 Mfd 2003* View details Winning BidN/A Lot 7 Olympus GIF-XQ240 Video Gastroscope in Case - Engineer's Report : Optical System -Ok , Angulation - Ok, Insertion Tube - Ok , Light Transmission - Ok, Channels - Ok,Leak Check - Ok *S/N 2913258 Mfd 1999* View details Winning BidN/A Lot 8 Olympus CF-240AL Video Gastroscope in Case - Engineer's Report : Optical System -Ok , Angulation - Not Reaching Specification / To be Adjusted, Insertion Tube - Ok , Light Transmission - Ok, Channels - Ok,Leak Check - Ok *S/N 2110297 Mfd 2001* View details Winning BidN/A Lot 9 Olympus OSF-3 Sigmoidoscope In Case Engineer's Report : Optical System - Multiple Broken Fibres, Angulation - Ok, Insertion Tube - Ok , Light Transmission - Ok, Channels - Ok, Leak Check - Ok *S/N 2800096 Mfd 2008 * View details Winning BidN/A Lot 10 Olympus CF-240AL Video Gastroscope in Case - Engineer's Report : Optical System -Ok, Angulation - Ok, Insertion Tube - Ok , Light Transmission - Ok, Channels - Ok,Leak Check - Ok *S/N 2210566 Mfd 2002* View details Winning BidN/A Lot 11 Olympus GIF XQ240 Video Gastroscope in Case - Engineer's Report : Optical System -Ok , Angulation - Not Reaching Specification / To be Adjusted, Insertion Tube - Badly Twisted at Grip , Light Transmission - Restricted, Channels - Ok,Leak Check - Ok *S/N 2913365 Mfd 1999* View details Winning BidN/A Lot 12 Olympus CHF Type P20 Cholodoscope- Engineer's Report : Optical System - 50+ Broken Fibres , Angulation - Ok, Insertion Tube - Severely Kinked, Light Transmission - Ok, Channels - Leak Check - *S/N 2521401 Mfd 1995* View details StatusUnsold Lot 13 Olympus GIF XQ240 Video Gastroscope - Engineer's Report : Optical System -Ok , Angulation - Bending Section Spongy, Insertion Tube - Minor Kink at Grip , Light Transmission - Ok, Channels - Ok, Leak Check - Ok *S/N 2235676 Mfd 2002* View details Winning BidN/A Lot 14 Olympus GIF XQ240 Video Gastroscope- Engineer's Report : Optical System - Ok , Angulation - Bendy Section Strained, Not Reaching Specification, Insertion Tube - Ok, Light Transmission - Ok, Channels - Ok Leak Check - Ok *S/N 2913252 Mfd 1999* View details Winning BidN/A Lot 15 Olympus GIF XQ240 Video Gastroscope- Engineer's Report : Optical System - Ok , Angulation - Not Reaching Specification, To be Adjusted, Insertion Tube - Ok, Light Transmission - Ok, Channels - Ok Leak Check - Ok *S/N 2913450 Mfd 2009* View details Winning BidN/A Lot 16 Olympus PCF 240L Video Colonoscope- Engineer's Report : Optical System - Slightly Misty, Angulation - Not Reaching Specification , To be Adjusted, Insertion Tube - Ok , Light Transmission - Ok, Channels - Ok, Leak Check - Ok *S/N 2800042 Mfd 1998* View details Winning BidN/A Lot 17 Olympus CF-240DL Video Colonoscope - Engineer's Report : Optical System - No Image, Angulation - Not Reaching Specification, Insertion Tube - Ok, Light Transmission - Ok, Channels - Ok, Leak Check - Ok*S/N 2300134 Mfd 2003* View details Winning BidN/A Lot 18 Olympus PCF 240L Video Colonoscope- Engineer's Report : Optical System - Very Minor Stain, Angulation - Ok, Insertion Tube - Ok , Light Transmission - Ok, Channels - Ok, Leak Check - Ok *S/N 2800066 Mfd 1998* View details Winning BidN/A Lot 19 Pentax EG 383OUT Ultrasound Gastroscope - Engineer's Report : Optical System - Untested, Angulation - Ok , Insertion Tube - Ok, Light Transmission - Ok, Channels -Untested, Leak Check - Untested *S/N E110203 Mfd Unknown* View details Winning BidN/A Lot 20 Pentax EC34-i10F Video Colonoscope - Engineer's Report : Optical System - Untested, Angulation - Ok , Insertion Tube - Crush Mark, Light Transmission - Ok , Channels - Untested, Leak Check - Ok *S/N A110096* View details Winning BidN/A Lot 21 Pentax EC34-i10F Video Colonoscope - Engineer's Report : Optical System - Untested, Angulation - Ok, Insertion Tube - Ok, Light Transmission - Ok, Channels - Ok, Leak Check - Ok *S/N A110283* View details Winning BidN/A Lot 22 Olympus Evis Lucera TJF-260V Duodenoscope in Case - Engineer's Report : Optical System - Ok, Angulation - Ok, Insertion Tube - Kinks and Indents, Light Transmission - Ok, Channels - Ok, Leak Check - Leakage Evident *S/N 2700456* **Mfd 2007** View details Winning BidN/A Lot 23 Olympus CF-240L Colonoscope in Case - Engineer's Report : Optical System - Ok, Angulation - Not Reaching Specification / To Be Adjusted , Insertion Tube - 1 x Kink, Light Transmission - Ok, Channels - Ok, Leak Check - Ok, Accessories - 1 x A/W Valve - Faulty *S/N 2800266* **Mfd 1998** View details Winning BidN/A Lot 24 Olympus PCF-230 Colonoscope in Case (Missing Handle) Engineer's Report : Optical System - Slight Stain on R/H Side of Image, Angulation - Not Reaching Specification / To Be Adjusted, Insertion Tube - Kinks and Indents, Light Transmission - Ok, Channels - Ok, Leak Check - Leakage Evident *S/N 2500122* **Mfd 1995** View details Winning BidN/A Lot 25 Pentax EG 29-i10 Video Colonoscope-Engineer's Report : Optical System - Untested, Angulation -Ok , Insertion Tube -Ok , Light Transmission - Ok, Channels - Untested, Leak Check - Ok *S/N 110469* View details Winning BidN/A Lot 26 Olympus CTF-5 Cystoscope - Engineer's Report : Optical System - 1 x Broken Fibre, Angulation - Ok, Insertion Tube - Bad Crush Mark, Light Transmission - Ok, Channels - Ok, Leak Check - Ok *S/N W704380* **Mfd 2007** View details Winning BidN/A Lot 27 Olympus CTF-5 Cystoscope - Engineer's Report : Optical System - 2 x Broken Fibres and Very Minor Stain, Angulation - Ok, Insertion Tube - Ok, Light Transmission - Ok, Channels - Ok, Leak Check - Ok *S/N W804489* **Mfd 2008** View details Winning BidN/A Lot 28 Olympus CTF-5 Cystoscope - Engineer's Report : Optical System - 1 x Broken Fibre and Slightly Misty, Angulation - Ok, Insertion Tube - Crush Mark, Light Transmission - Ok, Channels - Ok, Leak Check - Excessive Leak *S/N W804447* **Mfd 2008** View details Winning BidN/A Lot 29 Olympus CTF-5 Cystoscope - Engineer's Report : Optical System - 1 x Broken Fibre and Slightly Misty, Angulation - Ok, Insertion Tube - Crush Mark, Light Transmission - Ok, Channels - Ok, Leak Check - Excessive Leak *S/N W804447* **Mfd 2008** View details Winning BidN/A Lot 30 Karl Storz 11302BD2 Intubation Endoscope in Case with Some Parts Dismantled - Engineer's Report : Optical System - No Broken Fibres, Angulation - N/A Dismantled, Insertion Tube - Crush Mark, Light Transmission - Ok, Channels - Ok, Leak Check - Ok, *S/N 2147342* **Mfd N/A** View details Winning BidN/A Lot 31 Pentax EG-3870UTK Video Ultrasound Gastroscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found *A120316* View details Winning BidN/A Lot 32 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 0 Broken Fibers, No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G114276* View details Winning BidN/A Lot 33 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 0 Broken Fibers, No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111896* View details Winning BidN/A Lot 34 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 0 Broken Fibers, No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G111509* View details Winning BidN/A Lot 35 Pentax FNL-10RBS Laryngoscope - Engineer's Report : Optical System - 0 Broken Fibers, No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found *G113372* View details Winning BidN/A Lot 36 Pentax FNL-10RP3 Nasolaryngoscope with Light Lead - Engineer's Report : Optical System - 0 Broken Fibers, No Fault Found, Angulation - Crush in Bending Section, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found *H1411148 View details Winning BidN/A Lot 37 Karl Storz 11301BN1 Flexible Intubation Scope - Engineer's Report : Optical System - 0 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found *2129945* View details Winning BidN/A Lot 38 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Strain on Shape, Light Transmission - No Fault Found, Channels - No Fault Found *2600403* View details Winning BidN/A Lot 39 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Indentation Present, Light Transmission - No Fault Found, Channels - No Fault Found *2900653* View details Winning BidN/A Lot 40 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found *2900654* View details Winning BidN/A Lot 41 Olympus OVC-200 Lecture Scope Attachment in Case - Engineer's Report : Optical System - No Fault Found View details StatusUnsold Lot 42 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 2 Broken Fibers, Minor Stain, Angulation - Not Reaching Specification and Strained, Insertion Tube - Kink Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W001273* View details StatusUnsold Lot 43 DP Medical Intubation Scope with Leak Tester and Light Cable in Case - Engineer's Report : Optical System - 1 Broken Fiber, Halo Mark on Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found View details Winning BidN/A Lot 44 Pentax FNL 10RBS Laryngoscope in Case - Engineer's Report : Optical System - No Broken Fibres, Angulation - Ok, Insertion Tube - Crush Marks, Light Transmission - Ok, Channels - Ok, Leak Check - Ok , Accessories Mini Light Sources *S/N G114543* **Mfd 1999** View details Winning BidN/A Lot 45 Pentax 3.2 EG29-i10 - Engineer's Report : Optical System - Untested, Angulation - Ok, Insertion Tube - Badly Kinked, Light Transmission - Ok, Channels - Ok, Leak Check - Ok *S/N A111428* **Mfd N/A** View details Winning BidN/A Lot 46 Olympus GF-UCT240 Ultrasonic Gastroscope - Engineer's Report : Optical System - Ok, Angulation - Not Reaching Specification / To be Adjusted, Insertion Tube - Bad Crush Mark, Light Transmission - Ok, Channels - Ok, Leak Check - Ok, Unable to Test Ultrasound *S/N 1800211* **Mfd 2008** View details Winning BidN/A Lot 47 Fujinon EG-450WRS Video Gastroscope in Case - Engineer's Report : Optical System - No Image, Angulation - Ok, Insertion Tube - Poly Peeling at Prox, Light Transmission - Ok, Channels - Ok, Leak Check - Excessive Leak *S/N 201A174* **Mfd 2004** View details Winning BidN/A Lot 47a Fujinon EG-530FP Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *374A392* View details Winning BidN/A Lot 48 Fujinon EG-530FP Video Gastroscope - Engineer's Report : Optical System - Function Buttons Not Engaging, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *314A134* View details Winning BidN/A Lot 49 Fujinon EG-530FP Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, To Be Adjusted, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *314A132* View details Winning BidN/A Lot 50 Fujinon EG-530FP Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *314A114* View details Winning BidN/A Lot 51 Fujinon EG-530FP Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *314A138* View details Winning BidN/A Lot 52 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault FOund *1300209* View details Winning BidN/A Lot 53 Fujinon EG-530FP Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush at Proximal End, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *314A1368 View details Winning BidN/A Lot 54 Karl Storz Stack System Including 1 x Karl Storz WideView HD Monitor, 1 x Storz 200903 31 Monitor, 1 x Karl Storz SCB Electronic Endoflator 264305 20 1 x Karl Storz Aida Control 200961 20 Unit, 2 x Karl Storz Xenon Nova 300 201340 20 Light Sources, 1 x Karl Storz Image 1 Hub 22010 20 Camera Control Unit, 1 x Sony UP-DR80MD Digital Graphic Printer (Powers Up) View details Winning BidN/A Lot 55 Karl Storz Stack System Including 1 x Karl Storz WideView HD Monitor, 1 x Storz 200905 19 Monitor, 1 x Karl Storz SCB Electronic Endoflator 264305 20, 2 x Karl Storz Xenon 300 201331 20 Light Sources, 1 x Karl Storz Aida Control 200961 20 Unit (HDD Removed), 1 x Karl Storz SCB Image 1 Hub 222010 20 Camera Control Unit and 1 x Sony UP-DR80MD Digital Colour Printer (Powers Up) View details Winning BidN/A Lot 56 Karl Storz Stack System Including 1 x Karl Storz WideView HD Monitor, 1 x Karl Storz 200903 31 Monitor, 1 x Karl Storz SCB Electronic Endoflator 264305 20, 1 x Storz S3 Image 1 Camera, 1 x Storz Aida Control 200961 20 Unit, 1 x Karl Storz Xenon Nova 300 201340 20 Light Source, 1 x Karl Storz SCB Image 1 Hub 222010 20 Camera Control Unit and 1 x Sony UP-DR80MD Digital Colour Printer (Powers Up) View details Winning BidN/A Lot 57 Karl Storz Stack System Including 1 x Karl Storz Radiance HD Monitor, 1 x Karl Storz 200905 19 Monitor, 1 x Karl Storz Aida Control NEO 200461 20 Unit (HDD Removed) 1 x Stryker X7000 Light Source, 1 x Karl Storz SCB Image 1 Hub 222010 20 Camera Control Unit and 1 x Karl Storz Electronic Endoflator 264305 20 (Powers Up) View details Winning BidN/A Lot 100 Olympus BF-1T260 Video Bronchoscope in Case *2302312* View details Winning BidN/A Lot 101 Olympus BF-1T260 Video Bronchoscope in Case *2302310* View details Winning BidN/A Lot 102 Olympus BF-XP260F Video Bronchoscope in Case *1400173* View details Winning BidN/A Lot 103 Olympus ENF-GP Endoscope in Case *1402013* View details Winning BidN/A Lot 104 Olympus CF-Q260DL Video Colonoscope in Case *2011459* View details Winning BidN/A Lot 105 Olympus CF-Q260DL Video Colonoscope in Case *2510251* View details Winning BidN/A Lot 106 Riester 3900 Pharyngoscope in Case *543848* View details Winning BidN/A Lot 107 Karl Storz 11278 SV Videoscope in Case View details Winning BidN/A Lot 108 Fujinon EC-760R Video Colonoscope in Case *729/198* View details Winning BidN/A Lot 109 Olympus GIF E Video Gastroscope in Case *2802118* View details Winning BidN/A Lot 110 Karl Storz 11272CU1 Cystoscope in Case *2165198* View details Winning BidN/A Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next