BRITISH MEDICAL AUCTIONS March 2021 Endoscopes (#325) 18/03/2021 2:00 PM GMT - 24/03/2021 1:48 PM GMT CLOSED Starts Ending 24/03/2021 1:00 PM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-43 of 43. Previous|1|Next Lot 1 Olympus CHF-Type P10 Fiber Choledochoscope Engineer's Report : Optics - One Broken Fiber, Angulation - Badly Strained, Patient Tube - Severely Kinked, Light Transmission - Ok, Channel System - Restricted, *S/N 2701689 Mfd- 1987* View details StatusUnsold Lot 2 Olympus BF Type P200 Video Bronchoscope In Carry Case Engineer's Report : Optics - Ok, Angulation - Excessive Play, Patient Tube - Severely Kinked, Light Guide Tube - Ok, Light Transmission - Ok, Leak Check - Ok *S/N 2300233 Mfd 1983* View details StatusUnsold Lot 3 Olympus CF Type P10S Sigmoidoscope in Case Engineer's Report : Optics - One Broken Fibre with Moisture in Optics , Angulation - Ok, Patient Tube - No Distal Hood, Light Guide Tube - Ok , Light Transmission - Ok, Channel System - Ok, *S/N 2511210 Mfd 1985* View details StatusUnsold Lot 4 Olympus CHF Type 240 Video Bronchoscope in Carry Case Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube -,Kink on Body, Light Transmission -Ok , Channel System - Ok, Leak Check - Ok, *S/N 2900650 Mfd 2009* View details StatusUnsold Lot 5 Olympus BF Type P10 Flexible Bronchoscope - Engineer's Report: Optics -Three Broken Fibres, Angulation -Ok, Patient Tube - Most of Sleeving Perished and Missing, Light Guide Tube - Ok, Light Transmission - Ok , Channel System -Ok, Leak Check - Unable to Hold Pressure *S/N 2501433 Mfd 1985* View details Winning BidN/A Lot 6 Olympus GIF XQ20 Video Gastroscope in Carry Case - Engineer's Report : Optics - Over 100+ Broken Fibres with Fluid Stain , Angulation - Not Reaching Specification, Patient Tube - Serverley Crushed, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Restricted, Leak Check - Leaking *S/N 2602692 Mfd 1986* View details StatusUnsold Lot 7 Olympus GIF-2T10 Video Gastroscope in Carry Case - Engineer's Report : Optics - Three Broken Fibres with Fluid Stain, Angulation - Not Reaching Specification, Patient Tube - Badly Kinked at Grip, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Small Leak- *S/N 2032115 Mfd 1990 * View details StatusUnsold Lot 8 Fujifilm EG-590 Video Gastroscope in Carry Case - Engineer's Report : Optics - Ok, Angulation - Not Reaching Specification, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 348K906* View details Winning BidN/A Lot 9 Fujifilm EC-530FL Video Gastroscope in Carry Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 654A139* View details Winning BidN/A Lot 10 Olympus GIF XQ240 Video Gastroscope - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2033327* **Mfd 2000** View details Winning BidN/A Lot 11 Olympus GIF XQ240 Video Gastroscope - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2336581* **Mfd 2003** View details Winning BidN/A Lot 12 Olympus GIF XQ240 Video Gastroscope - Engineer's Report : Optics - Unable to Check Due to Pigtail Lead not Able to Attach to Scope, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2134278* **Mfd 2001** View details Winning BidN/A Lot 13 Olympus GIF XQ240 Video Gastroscope - Engineer's Report : Optics - Ok, Angulation - Not Reaching Specification, Patient Tube - Indentations, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2033013* **Mfd 2000** View details Winning BidN/A Lot 14 Olympus GIF XQ240 Video Gastroscope - Engineer's Report : Optics - Ok, Angulation - Not Reaching Specification - Spongy, Patient Tube - Indentations, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2235159* **Mfd 2004** View details Winning BidN/A Lot 15 Olympus CF 240AL Colonoscope in Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2420747* **Mfd 2004** View details Winning BidN/A Lot 16 Olympus CF-Q240L Colonoscope in Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2800116* **Mfd 1998** View details Winning BidN/A Lot 17 Olympus CF 240AL Colonoscope in Box - Engineer's Report : Optics - Ok, Angulation - Not Reaching Specification, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2999777* **Mfd 2009** View details Winning BidN/A Lot 18 Olympus GIF XQ240 Video Gastroscope in Box - Engineer's Report : Optics - Ok, Angulation - Not Reaching Specification, Patient Tube - Indentations, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2032181* **Mfd 2000** View details Winning BidN/A Lot 19 Olympus CF 240AL Colonoscope in Box - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2972762* **Mfd 1999** View details Winning BidN/A Lot 20 Fujinon EG-590WR Video Gastroscope in Carry Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 348A403* View details Winning BidN/A Lot 21 Fujinon EC 450WL5 Video Colonoscope in Carry Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok *S/N 308A269 Mfd 2004* View details StatusUnsold Lot 22 Fujinon EG-590WR Video Colonoscope in Carry Case - Engineer's Report : Optics - Ok, Angulation -Not Reaching Specification, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 348A404* View details Winning BidN/A Lot 23 Fujinon EC 450WL5 Video Colonoscope in Carry Case - Engineer's Report : Optics - Ok, Angulation - Up Angulation Broken, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok *S/N 303A268 Mfd 2005* View details Winning BidN/A Lot 24 Olympus CF 240AL Colonoscope in Box - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Indentations, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2210552* **Mfd 2002** View details Winning BidN/A Lot 25 Fujinon Video Unknown Model Endoscope in Carry Case Engineer's Report : Optics - Some Interference Lines, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - (Unknown Model Due to Missing Model Plate-See Photo) *S/N 2G201A255 Mfd 2005* View details Winning BidN/A Lot 26 Olympus GIF XQ240 Video Gastroscope in Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Indentation, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2336582* **Mfd 2003** View details Winning BidN/A Lot 27 Fujinon EY-470S/B Video Cystoscope in Carry Case- Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Indentation, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 135A406 Mfd- 2005* View details Winning BidN/A Lot 28 Olympus GIF XQ240 Video Gastroscope in Case - Engineer's Report : Optics - Ok, Angulation - Not Reaching Specification, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2236493* **Mfd 2002** View details Winning BidN/A Lot 29 Fujinon EB 530S Video Bronchoscope in Carry Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Kinked at Grip, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 061A004 Mfd 2009* View details Winning BidN/A Lot 30 Olympus CF 240AL Colonoscope in Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2210530* **Mfd 2002** View details Winning BidN/A Lot 31 Fujinon EY-470S/B Video Cystoscope in Carry Case- Engineer's Report : Optics - Ok, Indentation - Ok, Patient Tube - Indentation, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 135A059 Mfd- 2006* View details Winning BidN/A Lot 32 Olympus Evis Lucera CF H260DL Colonoscope in Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - with Forceps and Accessories*S/N 2900418* **Mfd 2009** View details Winning BidN/A Lot 33 Fujinon EY-470S/B Video Cystoscope in Carry Case- Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Crush Marks, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 135A05 Mfd 2006* View details Winning BidN/A Lot 34 Olympus CYF-5 Fiberscope - Engineer's Report : Optics - 30 Broken Fibres, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok - *S/N 2900116* **Mfd 2009** View details Winning BidN/A Lot 35 Fujinon EY-470S/B Video Cystoscope in Case *Mfd 2011* **RY135AO35** View details Winning BidN/A Lot 36 Olympus CYF-2 Video Cystoscope in Case (Multiple Broken Fibres) *W101000* View details StatusUnsold Lot 37 Pentax FI-13RBS Intubation Scope (No Broken Fibres) *S/N A110059* View details Winning BidN/A Lot 38 Pentax FNL-10RP3 Rhinolaryngoscope in Case (Cloudy View with Multiple Broken Fibres) *H141796* View details StatusUnsold Lot 39 Job Lot Including 1 x Olympus MAJ-953 Probe Drive Processor, 1 x Pentax PVA-1000 Endoscope Video Converter (Damaged Outer Cable-See Photo) and 2 x Olympus Light Cables View details StatusUnsold Lot 40 Karl Storz 7200B 30 Degree Arthroscope (No View- Damaged Optic) View details Winning BidN/A Lot 41 Pentax EC-380LP Video Colonoscope in Case * SN A01073* View details Winning BidN/A Lot 42 Olympus BF Type P20D Fiber Bronchoscope in Case *S/N 2001281 Mfd-1992* *Engineers Report: Optical System- One Broken Fibre, Angulation- Not Reaching Specification, Insertion Tube- Dull Sheath, Minor Kink, Light Transmission- Ok, Channels- Ok* View details StatusUnsold Lot 43 Fujinon ES-450WES Video Gastroscope In Case Engineer's Report : Optics - No Fault Found, Angulation - Ok Will Require Slight Adjustment , Patient Tube - No Fault Found, Light Guide Tube - No Fault Found, Light Transmission - No Fault Found, Channel System - No Fault Found. Leak Check- No Leak *S/N 20357A065* *Mfd 2007* View details Winning BidN/A Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next