April 2021 Two Day Live Medical Equipment Auction April 8, 2021 View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 101. Previous|12|Next Image Lot # Item Title Time Left Your Bids 11 CTL Medical Stack Trolley Including Olympus OTV-SI Digital Processor (Powers Up) * SN 7356116 * 1 Winning BidN/AStatusSold View details 33 1 x Stryker Stack Trolley with Stryker SDC HD High Definition Digital Capture Unit and 1 x Pentax Stack Trolley 1 Winning BidN/AStatusSold View details 42 Karl Storz Stack Trolley with Tangent Flat Screen Monitor with Power Supply 1 Winning BidN/AStatusSold View details 49 Karl Storz Stack Trolley Including Karl Storz Dx-cam ntsc 202301 20,Karl Storz Tricam SL ntsc 202221 20,Karl Storz SCB Equimat 203020 20,Karl Storz Flash 201330 30,Karl Storz Xenon 300 201331 20 and Sony Digital Color Printer UP-DR80MD (Powers Up) 1 Winning BidN/AStatusSold View details 51 Olympus Compact Stack Trolley Including Olympus OEV181H Monitor,Olympus OTV-SI Digital Processor and Olympus UHI-2 Insufflator (Powers Up) 1 Winning BidN/AStatusSold View details 100 Karl Storz Stack Trolley With Storz 20090331 Monitor And Storz Carry Case With Accessories (Powers Up) *SN GA1108* 1 Winning BidN/AStatusSold View details 101 Karl Storz Stack Trolley 1 Winning BidN/AStatusSold View details 106 2 x Olympus Stack Trolleys With Olympus OEV261H LCD Monitor, Olympus EVIS Lucera CV-260SL Digital Processor, Olympus EVIS Lucera CLV-260SL Processor/Light Source Unit, Olympus MAJ-1154 Pigtail Connector, Olympus Keyboard, Sony Color Video Printer UP-21MD And Olympus Connector Cables (Powers Up) * SN 7002174/59887/7047538/7035768* 1 Winning BidN/AStatusSold View details 113 Karl Storz Stack Trolley Including Storz SCB AIDA DVD 202040 20 Unit and Connector Cable (Powers Up) *GH* 1 Winning BidN/AStatusSold View details 118 Stryker Stack Trolley With Stryker Vision Elect HD Monitor (Powers Up) 1 Winning BidN/AStatusSold View details 147 2 x Karl Storz Stack Trolleys with 1 x Storz AIDA Control 200960 20 Unit 1 Winning BidN/AStatusSold View details 148 EUK Stack Trolley with 3 x Sony UP-21MD Colour Video Printers and Olympus OES UHI-3 Insufflator (Powers Up) 1 Winning BidN/AStatusSold View details 149 1 x Olympus TC-C1 Clinical Trolley and 1 x Olympus Keymed Video Trolley TV-2 with Sony Trinitron Monitor * Monitor Damaged-See Photos * 1 Winning BidN/AStatusSold View details 151 2 x Stryker Stack Trolleys with 1 x Sony Trinitron Monitor and Sony Color Video Printer (Powers Up) 1 Winning BidN/AStatusSold View details 152 CTL Medical Stack Trolley with Sony Trinitron Monitor, Zeiss MediLive Advanced Digital Camera Control Unit and Cables (Powers Up) *C* 1 Winning BidN/AStatusSold View details 153 1 x Fujinon Stack Trolley with Sony Color Video Printer and 1 x Olympus WM-SC Workstation Stack Trolley 1 Winning BidN/AStatusSold View details 155 DP Medical Stack Trolley with Mediscan Kestrel Monitor, Sony DSR-20MDP Digital Video Cassette Recorder, Kappa DVC 750 Camera Control Unit, Footswitch and Samsung Printer (Powers Up) *S/N 10510* 1 Winning BidN/AStatusSold View details 157 Laryngograph Ltd Mini Stack Trolley with Keyboard,Laryngograph Processor with Hitachi CCD Color Camera Head Model KP-D20BP,LxStrobe Light Source and Printer 1 Winning BidN/AStatusSold View details 160 2 x Karl Storz Stack Trolleys 1 Winning BidN/AStatusSold View details 162 Laryngograph Stack Trolley with Monitor, Perkin Elmer Cermax Xenon Fiber-Optic Light Source, Laryngograph LXC-2010 Digital Video Camera Control Unit and Camera Head (Powers Up - HDD Removed) *09HXL3000D3452* 1 Winning BidN/AStatusSold View details 175 Stack Trolley with Sony Trinitron Monitor and Olympus OTV-S6 Camera Control Unit (Powers Up- Damage to Back of Monitor-See Photos) 1 Winning BidN/AStatusSold View details 176 Karl Storz Stack Trolley Including Sony LCD Monitor,Richard Wolf Endolight LED 1.2 Light Source Unit,Richard Wolf Endocam Performance HD Camera Control Unit, Richard Wolf 5514901 PAL Camera Head and Gynecare Versapoint Unit with Footswitch (Powers Up-Unable to Test Camera Due to Damaged Screen-See Photos) * SN 3206302 / 1100195250 / 1100219314 * 1 Winning BidN/AStatusSold View details 177 2 x Olympus Stack Trolleys Including Richard Wolf 2232 Laparo CO2 PNEU Insufflator Unit and Olympus Evis CLV-U40 Light Source Processor (Powers Up) 1 Winning BidN/AStatusSold View details 178 Olympus WM-30 Mobile Workstation Stack Trolley Including Olympus Surgical CO2 Insufflator 9L and Connector Cables (Powers Up) 1 Winning BidN/AStatusSold View details 361 2 x Linvatec IM3331 3CCD Autoclave Camera Heads 1 Winning BidN/AStatusSold View details 362 Job Lot Including 1 x Storz 263310 20 hamou endomat Unit (Powers Up) and 1 x Storz WideView HD Monitor (Unable to Power Up due to No Power Supply) 1 Winning BidN/AStatusSold View details 370 Mixed Lot Including 2 x Gynecare Thermachoice II Units and 2 x Explorent 810150 Halogen Light Source Units *8743 / 8745 / R23367 / R27205* 1 Winning BidN/AStatusSold View details 385 Olympus A50002A 30 Degree 10mm EndoEye in Case 1 Winning BidN/AStatusSold View details 447 1 x Dyonics ED-3 Enhanced Digital 3-Chip Camera Unit, 3 x Smith and Nephew 460P 3-CCD Digital Camera Control Units and 1 x Smith and Nephew 450P 3-CCD Digital Camera Control Unit (All Power Up) 1 Winning BidN/AStatusSold View details 448 1 x Gyrus G400 WorkStation Version V2.07, 1 x ArthroCare Quantum 2 Electrosurgical System and 1 x Smith and Nephew Dyonics Access 15 Fluid Management System (All Power Up) 1 Winning BidN/AStatusSold View details 449 1 x Aesculap 3 CCD-Camera Control Unit and 1 x Aesculap ELAN-E Surgical Power Tool (Both Power Up) 1 StatusCLOSED View details 455 Stryker L9000 Light Source (Powers Up) 1 Winning BidN/AStatusSold View details 456 2 x DePuy Mitek VAPR Vue Radiofrequency System Version 01.03 (Both Power Up) 1 Winning BidN/AStatusSold View details 457 Karl Storz 200430 20 tele pack pal Light Source / Processor Unit in Carry Case (Powers Up) 1 Winning BidN/AStatusSold View details 493 Storz WideView HD Monitor (Unable to Power Test Due to No Power Supply - Marks on Screen and Surround) 1 Winning BidN/AStatusSold View details 569 2 x Medi-Tech 0 Degree Ref 19.551.020.000.3120 Rigid Endoscopes with 2 x Light Source Cables and 2 x Sheaths * 2 x Image Cloudy * 1 Winning BidN/AStatusSold View details 570 2 x Medi-Tech 0 Degree Ref 19.551.020.000.3120 Rigid Endoscopes with 2 x Light Source Cables and 1 x Sheath * 1 x Image Cloudy 1 x Image Ok * 1 Winning BidN/AStatusSold View details 584 Olympus OTV-SP IH-NA-12E 3CCD Camera Head *1400235* 1 Winning BidN/AStatusSold View details 585 2 x Olympus OTV-S7 Camera Heads (Missing Couplers) 1 Winning BidN/AStatusSold View details 586 2 x Olympus OTV-S7 Camera Heads (Missing Couplers) 1 Winning BidN/AStatusSold View details 587 2 x Olympus OTV-S7 Camera Heads (Missing Couplers) 1 Winning BidN/AStatusSold View details 595 R.Wolf 8650.405 70 Degree Panoview Plus Arthroscope (Slightly Cloudy View) 1 StatusUnsold View details 596 1 x Karl Storz 27015C 70 Degree Hopkins Telescope (Cloudy View) and 1 x Aesculap PE 528A Telescope (Slightly Cloudy View) 1 Winning BidN/AStatusSold View details 597 Aesculap 30 Degree E 508A Telescope (Slightly Cloudy View) 1 StatusUnsold View details 598 Job Lot of 7 x Endoscopes Including 3 x Atlantech and 1 x Aesculap (All Damaged / Cloudy View) 1 Winning BidN/AStatusSold View details 642 Stryker 1188HD Endoscopy Camera Head Ref 1188-210-105 * SN 06J075384* 1 Winning BidN/AStatusSold View details 643 Stryker 1188HD Endoscopy Camera Head Ref 1188-210-105 * SN 09B001264* 1 Winning BidN/AStatusSold View details 645 Job Lot Including 2 x Machida LY-C30 Rigid Rhinolaryngoscopes and 1 x Nagashima SFT-I Rigid Scope in Case *9796 1 Winning BidN/AStatusSold View details 665 Olympus Evis Exera II CV-180 Camera Control Unit (Powers Up) *7778913* 1 Winning BidN/AStatusSold View details 666 Olympus Evis Exera II CLV-180 Xenon Light Source *7805396* 1 Winning BidN/AStatusSold View details 667 Olympus Evis Exera II CLV-180 Xenon Light Source *7601919* 1 Winning BidN/AStatusSold View details 669 Karl Storz Image 1 S3 Camera Head 22220030 PAL *S/N FF616335-H* 1 Winning BidN/AStatusSold View details 740 Olympus CLK-4 Light Source (Powers Up with Good Bulb) 1 Winning BidN/AStatusSold View details 1059 2 x Olympus Stack Trolleys with Olympus OEV191H Monitor, Olympus Evis Lucera CV-260 Digital Processor, Olympus Evis Lucera CLV-260SL Light Source, Olympus ECS-260 Connector Cable and Olympus MAJ-1154 Pigtail Connector (Powers Up) 1 Winning BidN/AStatusSold View details 1069 Storz Stack System with Storz Monitor, Storz 201315 20 Xenon Nova Light Source, Storz 222000 20 SCB Image 1 Hub Camera Control Unit and Sony Colour Video Printer (Powers Up) 1 Winning BidN/AStatusSold View details 1080 Lemke Urology Stack Trolley with Lemke XR 140 Monitor, Richard Wolf 2233 LAPARO CO2 Pneu Insufflator, Cuda LED 2000 Light Source, Lemke Vision TC840 Camera Control Unit, Lemke XL202 Light Source and C480705 Camera Head (Powers Up) 1 Winning BidN/AStatusSold View details 1085 Storz Stack System with Storz Monitor (Powers Up) 1 Winning BidN/AStatusSold View details 1111 Stryker Stack Trolley Including Sony HR Trinitron Monitor (Powers Up) 1 Winning BidN/AStatusSold View details 1203 Olympus Stack Trolley with Sony Monitor (Unable to Power Test Due to No Power Supply) 1 Winning BidN/AStatusSold View details 1209 Pentax Stack Trolley with Pentax EPK-i Video Processor (Powers Up - Blank Screen) 1 Winning BidN/AStatusSold View details 1236 Stack Trolley Including Sony Trinitron Monitor, Storz Telecam SL Pal 202120 20 Camera Control Unit.Storz Xenon Nova 201315 20 Light Source Unit,Storz Telecam 20212030 PAL Camera Head,Storz Telecam-B 20212031 PAL Camera Head and Sony Multimedia Interface Unit (Powers Up-Unable To Test Correctly Due to No Output from Camera Control Unit-Light Source No Power-Damage to Side of Monitor) * SN 2011663 / LI10459 / LIP035827 * 1 Winning BidN/AStatusSold View details 1237 Stack Trolley Including Sony Trinitron Monitor,Keyboard and Connector Cables (Powers Up) * SN 2009320 * 1 Winning BidN/AStatusSold View details 1382 2 x Storz Cases and 1 x Olympus Case 1 Winning BidN/AStatusSold View details 1407 Job Lot Including 1 x Karl Storz Medipack Pal 200430 20 Light Source / Processor Unit (Powers Up) 2 x Karl Storz 201340 20 Xenon Nova 300 Light Source Units (1 Powers Up with Faulty Bulb, 1 No Power) 1 x Karl Storz 201331 20 SCB xenon 300 Light Source Unit (No Power) 1 Winning BidN/AStatusSold View details 1418 Autoclave C3288 Camera Head 1 Winning BidN/AStatusSold View details 1419 Dyonics HD 900 Camera Head 1 Winning BidN/AStatusSold View details 1420 Dyonics HD 900 Camera Head 1 Winning BidN/AStatusSold View details 1430 5 x Olympus Leakage Testers 1 Winning BidN/AStatusSold View details 1466 Olympus EVIS OVC-200 Video Converter in Carry Case 1 StatusUnsold View details 1474 Olympus Job Lot Including 1 x Olympus EVIS Exera II CLV-180 Light Source, 1 x Olympus EVIS CV-240 Processor Unit and 1 x Olympus EVIS CV-200 Processor Unit (All Power Up) 1 Winning BidN/AStatusSold View details 1476 Olympus OTV-SX2 Digital 3CCD Camera in Carry Case 1 Winning BidN/AStatusSold View details 1497 Mixed Lot Including 1 x Sony Trinitron PVM-145MDE Color Video Monitor and 1 x Sony SV0-9500MDP Video Cassette Recorder with 1 x Sony SVRM-100A Remote Control (Both Power Up) 1 Winning BidN/AStatusSold View details 1506 5 x Light Source Cables 1 Winning BidN/AStatusSold View details 1507 5 x Light Source Cables 1 Winning BidN/AStatusSold View details 1520 Olympus A220065A Working Element with 1 x Olympus A200777A Obturator 1 Winning BidN/AStatusSold View details 1522 Richard Wolf 7mm 0 Degree Laparoscope *Cloudy View* 1 Winning BidN/AStatusSold View details 1523 Olympus O Degree 5mm Laparoscope *Cloudy View* 1 Winning BidN/AStatusSold View details 1526 Olympus EVIS Type 100L Video Colonoscope in Carry Case 1 Winning BidN/AStatusSold View details 1612 Olympus CHF-Type P10 Fiber Choledochoscope Engineer's Report : Optics - One Broken Fiber, Angulation - Badly Strained, Patient Tube - Severely Kinked, Light Transmission - Ok, Channel System - Restricted, *S/N 2701689 Mfd- 1987* 1 StatusUnsold View details 1613 Olympus BF Type P200 Video Bronchoscope In Carry Case Engineer's Report : Optics - Ok, Angulation - Excessive Play, Patient Tube - Severely Kinked, Light Guide Tube - Ok, Light Transmission - Ok, Leak Check - Ok *S/N 2300233 Mfd 1983* 1 Winning BidN/AStatusSold View details 1614 Olympus CF Type P10S Sigmoidoscope in Case Engineer's Report : Optics - One Broken Fibre with Moisture in Optics , Angulation - Ok, Patient Tube - No Distal Hood, Light Guide Tube - Ok , Light Transmission - Ok, Channel System - Ok, *S/N 2511210 Mfd 1985* 1 StatusUnsold View details 1615 Olympus CHF Type 240 Video Bronchoscopy in Carry Case Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube -,Kink on Body, Light Transmission -Ok , Channel System - Ok, Leak Check - Ok, *S/N 2900650 Mfd 2009* 1 StatusUnsold View details 1616 Olympus GIF XQ20 Video Gastroscope in Carry Case - Engineer's Report : Optics - Over 100+ Broken Fibres with Fluid Stain , Angulation - Not Reaching Specification, Patient Tube - Serverley Crushed, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Restricted, Leak Check - Leaking *S/N 2602692 Mfd 1986* 1 StatusUnsold View details 1617 Olympus GIF-2T10 Video Gastroscope in Carry Case - Engineer's Report : Optics - Three Broken Fibres with Fluid Stain, Angulation - Not Reaching Specification, Patient Tube - Badly Kinked at Grip, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Small Leak- *S/N 2032115 Mfd 1990 * 1 StatusUnsold View details 1618 Fujinon EC 450WLS Video Colonoscope in Carry Case - Engineer's Report : Optics - Ok, Angulation - Ok, Patient Tube - Ok, Light Guide Tube - Ok, Light Transmission - Ok, Channel System - Ok, Leak Check - Ok *S/N 308A269 Mfd 2004* 1 Winning BidN/AStatusSold View details 1619 Olympus CYF-2 Video Cystoscope in Case (Multiple Broken Fibres) *W101000* 1 StatusUnsold View details 1620 Pentax FNL-10RP3 Rhinolaryngoscope in Case (Cloudy View with Multiple Broken Fibres) *H141796* 1 Winning BidN/AStatusSold View details 1621 Job Lot Including 1 x Olympus MAJ-953 Probe Drive Processor, 1 x Pentax PVA-1000 Endoscope Video Converter (Damaged Outer Cable-See Photo) and 2 x Olympus Light Cables 1 Winning BidN/AStatusSold View details 1622 Olympus BF Type P20D Fiber Bronchoscope in Case *S/N 2001281 Mfd-1992* *Engineers Report: Optical System- One Broken Fibre, Angulation- Not Reaching Specification, Insertion Tube- Dull Sheath, Minor Kink, Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 1659 1 x Karl Storz 201315 20 Xenon Nova Light Source Unit (Powers Up with Missing Cover-See Photo) 1 x Karl Storz 202320 20 Telecam DX pal Camera Control Unit(Powers Up) *S/N 03925 / LLP021467* 1 Winning BidN/AStatusSold View details 1711 Pentax EPK-1000 Video Processor Unit (Powers Up) *EC012092 / 014465* 1 Winning BidN/AStatusSold View details 3003 Olympus Stack System with Olympus OEV191H Monitor, Olympus MAJ-1924 Keyboard, Olympus Evis Lucera Elite CV-290 Control Unit, Olympus Evis Lucera Elite CLV-290SL Light Source and Olympus MAJ-1911 Pigtail Connector Winning BidN/AStatusSold View details 3004 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found *W704372* Winning BidN/AStatusSold View details 3005 Olympus ENF-PF Enteroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *W111830* Winning BidN/AStatusSold View details 3006 Olympus GIF-2T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Requires Adjustment, Insertion Tube - Badly Kinked at Body, Bending Section Rubber Glue Poor, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2030245* Winning BidN/AStatusSold View details 3007 Olympus GIF-2T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Requires Adjustment, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2930105* Winning BidN/AStatusSold View details 3008 Olympus GIF-2T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Cement Poor and Snaking Tube, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2030187* Winning BidN/AStatusSold View details 3009 Pentax EG-29iLO Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found *110471* Winning BidN/AStatusSold View details 3010 Pentax EC-34iLOF Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bending Section Rubber Glue Very Bulbous *A110095* Winning BidN/AStatusSold View details 3011 Pentax EC-34iLOF Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A10100* Winning BidN/AStatusSold View details Items per page 102550100 Previous|12|Next Previous 12 Next