February 2021 Timed Endoscopy Equipment *Ending Friday 19th February* 13/02/2021 1:21 PM GMT - 19/02/2021 1:52 PM GMT View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-50 of 50. Previous|1|Next Image Lot # Item Title Time Left Your Bids 1 Olympus CF-240L Colonoscope in Case with Olympus MAJ-977 Pigtail Connector *Engineers Report: Optical System- Severe Interference, Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok, Accessories- MIT-997 Pigtail Cable* 1 Winning BidN/AStatusSold View details 2 Olympus BF Type XP40 Bronchoscope in Case *S/N 1L0056T Mfd-2002* *Engineers Report: Optical System- 30 Plus BF, Angulation- Ok, Insertion Tube- Scratched, Stained, Minor Indentations, Light Transmission- Ok, Channels- Ok, Leak Check-Major Leak* 1 Winning BidN/AStatusSold View details 3 Olympus TJF Type 260V Duodenoscope in Case *S/N 2700456 Mfd-2007* *Engineers Report: Optical System- Ok, Angulation- Ok, Insertion Tube- Ok , Light Transmission- Ok, Channels- Ok* 1 StatusUnsold View details 4 Fujinon EC-530WL Colonoscope in Case *S/N 447A554 Mfd-2008* *Engineers Report: Optical System-Ok , Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 5 Olympus GF Type UCT-240-AL5 Ultrasonic Gastroscope in Case *S/N 100005 Mfd-2001* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification, To be Adjusted , Insertion Tube- Ok, Light Transmission- Ok, Channels* 1 Winning BidN/AStatusSold View details 6 Fujinon EB-470S Bronchoscope in Case *S/N 046A178 Mfd-2008* *Engineers Report: Optical System- Ok, Angulation- Ok, Insertion Tube- Kink at Grip, Light Transmission- Ok, Channels- Ok Including Valves* 1 Winning BidN/AStatusSold View details 7 Fujinon EC-530WL Colonoscope in Case *S/N 447A324* *Engineers Report: Optical System- Unable to Check Image, Angulation- Ok, Insertion Tube- Ok , Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 9 Fujinon EC-450LP5 Slim Colonoscope in Case *S/N 285A222 Mfd- 2004* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification, To be Adjusted, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 10 Olympus BF Type P20D Fiber Bronchoscope in Case *S/N 2001281 Mfd-1992* *Engineers Report: Optical System- One Broken Fibre, Angulation- Not Reaching Specification, Insertion Tube- Dull Sheath, Minor Kink, Light Transmission- Ok, Channels- Ok* 1 StatusUnsold View details 13 Olympus CF Type 200HL Colonoscope in Case *S/N 2600005 Mfd-1986* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification, Insertion Tube- Strained, Light Transmission- Ok, Channels- 260 Series Valves* 1 StatusUnsold View details 14 Pentax VNL-1170K Nasondoscope in Case *S/N G120174* *Engineers Report: Optical System- Unable to Check, Angulation- Ok , Insertion Tube- Split in Sheath, Minor Crush Marks, Light Transmission- Ok, Channels- Ok, Leak Check- Leak from Insertion Tube* 1 Winning BidN/AStatusSold View details 15 Olympus GIF-Q200 Gastroscope in Case *S/N 2000273 Mfd-1990* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification To Be Adjusted, Insertion Tube- Ok, Light Transmission- Ok , Channels- Including Valves* 1 StatusUnsold View details 16 Olympus CF-200S Sigmoidoscope in Case *S/N 2510939 Mfd- 1985* *Engineers Report: Optical System- Ok, Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 17 Olympus PCF-240S Video Sigmoidoscope *S/N 2300148 Mfd- 2003* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification To Be Adjusted, Insertion Tube- Ok , Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 18 Pentax VNL-1170K Nasoendoscope in Case *S/N G120178* *Engineers Report: Optical System- Unable To Check, Angulation- Ok, Insertion Tube- Badly Kinked, Light Transmission- Ok, Channels- Ok, Leak Check- Leak From Plug, Comments- Light Guide Tube Kinked and Grip Misplaced* 1 Winning BidN/AStatusSold View details 19 Olympus GIF-XP260 Video Gastroscope in Case *S/N 2411065 Mfd 2004* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification, Insertion Tube- Poly Coating Peeling, Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 21 Olympus ENF Type P4 Rhinolaryngoscope in Case *S/N 2139091 Mfd-2003* *Engineers Report: Optical System- Multiple Broken Fibres, Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok , Channels- Ok* 1 Winning BidN/AStatusSold View details 22 Olympus LF-TP Intubation Fiberscope (1 x Broken Fiber) with Olympus MAJ-524 Portable Light Source (Untested Due to No Battery) 1 Winning BidN/AStatusSold View details 23 Olympus OES CYF-5 Cysto-Nephro Fiberscope (2 x Broken Fibers and Mark on Lense) 1 Winning BidN/AStatusSold View details 24 Olympus OES CYF-5 Cysto-Nephro Fiberscope (No Broken Fibers) 1 Winning BidN/AStatusSold View details 25 Olympus OES CYF-5 Cysto-Nephro Fiberscope (No Broken Fibers) 1 Winning BidN/AStatusSold View details 26 Job Lot Including 2 x Sopro Comeg 161271760 0 Degree Rigid Scopes and 1 x Sopro Comeg 161401802 30 Degree Rigid Scope (All Spares and Repairs) 1 Winning BidN/AStatusSold View details 27 Olympus CF-20HI Colonoscope in Box (3 x Broken Fibers) 1 Winning BidN/AStatusSold View details 28 Olympus PCF-230 Video Colonoscope in Case 1 Winning BidN/AStatusSold View details 29 Olympus Vet-3M Video Gastroscope in Case 1 Winning BidN/AStatusSold View details 30 Pentax EC-3840LK Video Colonoscope in Case 1 Winning BidN/AStatusSold View details 31 Pentax EC-3870LK 4.2 Video Colonoscope in Case 1 Winning BidN/AStatusSold View details 32 Olympus CF-10M Colonoscope in Case (Multiple Broken Fibers) 1 Winning BidN/AStatusSold View details 33 Olympus GIF-PQ20 Gastroscope in Case (Multiple Broken Fibers) 1 Winning BidN/AStatusSold View details 34 Olympus CF-100L Video Colonoscope in Case 1 Winning BidN/AStatusSold View details 35 Fujinon EG-470N5 Video Nasopharyngoscope in Case 1 Winning BidN/AStatusSold View details 36 Fujinon EC-3870LK Video Colonoscope in Case 1 Winning BidN/AStatusSold View details 37 Olympus OEV261H Monitor (Untested Due to No Power Supply) 1 Winning BidN/AStatusSold View details 38 Pentax EPK-i Video Processor (Powers Up, Scratch on Screen - See Photo) 1 Winning BidN/AStatusSold View details 39 Pentax PCF 230 Colonoscope *S/N 2601191 Mfd-1996* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification To be Adjusted, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 40 Acutronic 10410 Laryngoscope *S/N 10410* *Engineers Report: Optical System- No Broken Fibres, Angulation- Ok , Insertion Tube- Kinked At Grip, Light Transmission- Ok, Channels- Ok , Comments Light Guide Tube Not Present* 1 Winning BidN/AStatusSold View details 41 Pentax FNL 10RP3 Fibre Naso Pharyngo Laryngoscope in Case *S/N G115308* *Engineers Report: Optical System- No Broken Fibres, Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 42 Olympus BF20D Bronchoscope *S/N 2900575 Mfd- 1989* *Engineers Report: Optical System- No Broken Fibres, Fluid Stain, Angulation- Ok, Insertion Tube- Kinked, Light Transmission- Ok* 1 Winning BidN/AStatusSold View details 43 Olympus HYF Type P Hysteroscope In Case *S/N W500497 Mfd- 1995* *Engineers Report: Optical System- One Broken Fiber, Angulation- Not Reaching Specification To Be Adjusted, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* 1 Winning BidN/AStatusSold View details 44 Karl Storz 11301 BN1 Flexible Intubation Endoscope In Case *S/N 2187397* *Engineers Report: Optical System- No Broken Fibres, Angulation- Ok , Insertion Tube- Ok , Light Transmission- Ok* 1 Winning BidN/AStatusSold View details 45 Atmos Pharyngo *S/N 406430* *Engineers Report: Optical System- Two Broken Fiber, Angulation- Ok, Insertion Tube-Bending Section Rubber Torn, Light Transmission- Ok, Channels- Ok, Leak Check- Leaking Bending Section Rubber, Accessories- 1 x Leak Tester, Comments- Light Guide Tube Not Present* 1 Winning BidN/AStatusSold View details 46 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W203958* 1 Winning BidN/AStatusSold View details 47 3 x Olympus Endoscope Cases 1 Winning BidN/AStatusSold View details 48 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 3 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W203961* 1 Winning BidN/AStatusSold View details 49 Pentax FCY-15P2 Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Insertion Tube - Crush in Bending Section, Light Transmission - No Fault Found, Channels - No Fault Found, Other Comments - Light Guide Tube Perishing and Grip at Body Adrift 1 Winning BidN/AStatusSold View details 50 Olympus CF-ITS2 Sigmoidoscope in Case - Engineer's Report : Optical System - 3 x Broken Fibers and Misty View, Angulation - Not Reaching Specification, Insertion Tube - Badly Worn, Light Transmission - No Fault Found, Channels - No Fault Found 1 StatusUnsold View details 51 Richard Wolf 7305.006 Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found 1 Winning BidN/AStatusSold View details 52 Pentax ES-3870K Sigmoidoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, 1 Winning BidN/AStatusSold View details 53 Pentax FNL-10RBS Laryngoscope with Pentax BS-LL1 Light Source in Case - Engineer's Report : Optical System - Multiple Broken Fibers, Angulation - Badly Crushed Bending Section, Insertion Tube - Crush Marks, Light Transmission - Broken Light Guide Bundle, Other Comments - Part of Control Body Broken Away 1 StatusUnsold View details 54 Olympus ECS-260 Connection Cable 1 StatusUnsold View details Items per page 102550100 Previous|1|Next Previous 1 Next