BRITISH MEDICAL AUCTIONS February 2021 Timed Endoscopy Equipment *Ending Friday 19th February* (#306) 13/02/2021 1:21 PM GMT - 19/02/2021 1:52 PM GMT CLOSED Starts Ending 19/02/2021 1:01 PM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-53 of 53. Previous|1|Next Lot 1 Olympus CF-240L Colonoscope in Case with Olympus MAJ-977 Pigtail Connector *Engineers Report: Optical System- Severe Interference, Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok, Accessories- MIT-997 Pigtail Cable* View details Winning BidN/A Lot 2 Olympus BF Type XP40 Bronchoscope in Case *S/N 1L0056T Mfd-2002* *Engineers Report: Optical System- 30 Plus BF, Angulation- Ok, Insertion Tube- Scratched, Stained, Minor Indentations, Light Transmission- Ok, Channels- Ok, Leak Check-Major Leak* View details Winning BidN/A Lot 3 Olympus TJF Type 260V Duodenoscope in Case *S/N 2700456 Mfd-2007* *Engineers Report: Optical System- Ok, Angulation- Ok, Insertion Tube- Ok , Light Transmission- Ok, Channels- Ok* View details StatusUnsold Lot 4 Fujinon EC-530WL Colonoscope in Case *S/N 447A554 Mfd-2008* *Engineers Report: Optical System-Ok , Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 5 Olympus GF Type UCT-240-AL5 Ultrasonic Gastroscope in Case *S/N 100005 Mfd-2001* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification, To be Adjusted , Insertion Tube- Ok, Light Transmission- Ok, Channels* View details Winning BidN/A Lot 6 Fujinon EB-470S Bronchoscope in Case *S/N 046A178 Mfd-2008* *Engineers Report: Optical System- Ok, Angulation- Ok, Insertion Tube- Kink at Grip, Light Transmission- Ok, Channels- Ok Including Valves* View details Winning BidN/A Lot 7 Fujinon EC-530WL Colonoscope in Case *S/N 447A324* *Engineers Report: Optical System- Unable to Check Image, Angulation- Ok, Insertion Tube- Ok , Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 9 Fujinon EC-450LP5 Slim Colonoscope in Case *S/N 285A222 Mfd- 2004* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification, To be Adjusted, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 10 Olympus BF Type P20D Fiber Bronchoscope in Case *S/N 2001281 Mfd-1992* *Engineers Report: Optical System- One Broken Fibre, Angulation- Not Reaching Specification, Insertion Tube- Dull Sheath, Minor Kink, Light Transmission- Ok, Channels- Ok* View details StatusUnsold Lot 13 Olympus CF Type 200HL Colonoscope in Case *S/N 2600005 Mfd-1986* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification, Insertion Tube- Strained, Light Transmission- Ok, Channels- 260 Series Valves* View details StatusUnsold Lot 14 Pentax VNL-1170K Nasondoscope in Case *S/N G120174* *Engineers Report: Optical System- Unable to Check, Angulation- Ok , Insertion Tube- Split in Sheath, Minor Crush Marks, Light Transmission- Ok, Channels- Ok, Leak Check- Leak from Insertion Tube* View details Winning BidN/A Lot 15 Olympus GIF-Q200 Gastroscope in Case *S/N 2000273 Mfd-1990* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification To Be Adjusted, Insertion Tube- Ok, Light Transmission- Ok , Channels- Including Valves* View details StatusUnsold Lot 16 Olympus CF-200S Sigmoidoscope in Case *S/N 2510939 Mfd- 1985* *Engineers Report: Optical System- Ok, Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 17 Olympus PCF-240S Video Sigmoidoscope *S/N 2300148 Mfd- 2003* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification To Be Adjusted, Insertion Tube- Ok , Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 18 Pentax VNL-1170K Nasoendoscope in Case *S/N G120178* *Engineers Report: Optical System- Unable To Check, Angulation- Ok, Insertion Tube- Badly Kinked, Light Transmission- Ok, Channels- Ok, Leak Check- Leak From Plug, Comments- Light Guide Tube Kinked and Grip Misplaced* View details Winning BidN/A Lot 19 Olympus GIF-XP260 Video Gastroscope in Case *S/N 2411065 Mfd 2004* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification, Insertion Tube- Poly Coating Peeling, Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 21 Olympus ENF Type P4 Rhinolaryngoscope in Case *S/N 2139091 Mfd-2003* *Engineers Report: Optical System- Multiple Broken Fibres, Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok , Channels- Ok* View details Winning BidN/A Lot 22 Olympus LF-TP Intubation Fiberscope (1 x Broken Fiber) with Olympus MAJ-524 Portable Light Source (Untested Due to No Battery) View details Winning BidN/A Lot 23 Olympus OES CYF-5 Cysto-Nephro Fiberscope (2 x Broken Fibers and Mark on Lense) View details Winning BidN/A Lot 24 Olympus OES CYF-5 Cysto-Nephro Fiberscope (No Broken Fibers) View details Winning BidN/A Lot 25 Olympus OES CYF-5 Cysto-Nephro Fiberscope (No Broken Fibers) View details Winning BidN/A Lot 26 Job Lot Including 2 x Sopro Comeg 161271760 0 Degree Rigid Scopes and 1 x Sopro Comeg 161401802 30 Degree Rigid Scope (All Spares and Repairs) View details Winning BidN/A Lot 27 Olympus CF-20HI Colonoscope in Box (3 x Broken Fibers) View details Winning BidN/A Lot 28 Olympus PCF-230 Video Colonoscope in Case View details Winning BidN/A Lot 29 Olympus Vet-3M Video Gastroscope in Case View details Winning BidN/A Lot 30 Pentax EC-3840LK Video Colonoscope in Case View details Winning BidN/A Lot 31 Pentax EC-3870LK 4.2 Video Colonoscope in Case View details Winning BidN/A Lot 32 Olympus CF-10M Colonoscope in Case (Multiple Broken Fibers) View details Winning BidN/A Lot 33 Olympus GIF-PQ20 Gastroscope in Case (Multiple Broken Fibers) View details Winning BidN/A Lot 34 Olympus CF-100L Video Colonoscope in Case View details Winning BidN/A Lot 35 Fujinon EG-470N5 Video Nasopharyngoscope in Case View details Winning BidN/A Lot 36 Fujinon EC-3870LK Video Colonoscope in Case View details Winning BidN/A Lot 37 Olympus OEV261H Monitor (Untested Due to No Power Supply) View details Winning BidN/A Lot 38 Pentax EPK-i Video Processor (Powers Up, Scratch on Screen - See Photo) View details Winning BidN/A Lot 39 Pentax PCF 230 Colonoscope *S/N 2601191 Mfd-1996* *Engineers Report: Optical System- Ok, Angulation- Not Reaching Specification To be Adjusted, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 40 Acutronic 10410 Laryngoscope *S/N 10410* *Engineers Report: Optical System- No Broken Fibres, Angulation- Ok , Insertion Tube- Kinked At Grip, Light Transmission- Ok, Channels- Ok , Comments Light Guide Tube Not Present* View details Winning BidN/A Lot 41 Pentax FNL 10RP3 Fibre Naso Pharyngo Laryngoscope in Case *S/N G115308* *Engineers Report: Optical System- No Broken Fibres, Angulation- Ok, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 42 Olympus BF20D Bronchoscope *S/N 2900575 Mfd- 1989* *Engineers Report: Optical System- No Broken Fibres, Fluid Stain, Angulation- Ok, Insertion Tube- Kinked, Light Transmission- Ok* View details Winning BidN/A Lot 43 Olympus HYF Type P Hysteroscope In Case *S/N W500497 Mfd- 1995* *Engineers Report: Optical System- One Broken Fiber, Angulation- Not Reaching Specification To Be Adjusted, Insertion Tube- Ok, Light Transmission- Ok, Channels- Ok* View details Winning BidN/A Lot 44 Karl Storz 11301 BN1 Flexible Intubation Endoscope In Case *S/N 2187397* *Engineers Report: Optical System- No Broken Fibres, Angulation- Ok , Insertion Tube- Ok , Light Transmission- Ok* View details Winning BidN/A Lot 45 Atmos Pharyngo *S/N 406430* *Engineers Report: Optical System- Two Broken Fiber, Angulation- Ok, Insertion Tube-Bending Section Rubber Torn, Light Transmission- Ok, Channels- Ok, Leak Check- Leaking Bending Section Rubber, Accessories- 1 x Leak Tester, Comments- Light Guide Tube Not Present* View details Winning BidN/A Lot 46 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W203958* View details Winning BidN/A Lot 47 3 x Olympus Endoscope Cases View details Winning BidN/A Lot 48 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optical System - 3 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W203961* View details Winning BidN/A Lot 49 Pentax FCY-15P2 Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Insertion Tube - Crush in Bending Section, Light Transmission - No Fault Found, Channels - No Fault Found, Other Comments - Light Guide Tube Perishing and Grip at Body Adrift View details Winning BidN/A Lot 50 Olympus CF-ITS2 Sigmoidoscope in Case - Engineer's Report : Optical System - 3 x Broken Fibers and Misty View, Angulation - Not Reaching Specification, Insertion Tube - Badly Worn, Light Transmission - No Fault Found, Channels - No Fault Found View details StatusUnsold Lot 51 Richard Wolf 7305.006 Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found View details Winning BidN/A Lot 52 Pentax ES-3870K Sigmoidoscope in Case - Engineer's Report : Optical System - Untested, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, View details Winning BidN/A Lot 53 Pentax FNL-10RBS Laryngoscope with Pentax BS-LL1 Light Source in Case - Engineer's Report : Optical System - Multiple Broken Fibers, Angulation - Badly Crushed Bending Section, Insertion Tube - Crush Marks, Light Transmission - Broken Light Guide Bundle, Other Comments - Part of Control Body Broken Away View details StatusUnsold Lot 54 Olympus ECS-260 Connection Cable View details StatusUnsold Lot 55 Olympus CYF-3 Cystoscope in Carry Case - Engineer's Report : Optics - No Broken Fibres, No Fault Found, Angulation - Down Short of Specification, Requires Adjustment, Insertion Tube - Bad Kink, Light Transmission - No Fault Found, Channels- Catch, Leak Test- No Fault Found, Accessories - None *S/N W400116* View details Winning BidN/A Lot 56 Olympus CF-H260DL Colonoscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found View details StatusUnsold Lot 57 Olympus GIF-H260 Gastroscope in Case - Engineer's Report : Optics - Condensation in Optics, Angulation - Not Reaching Specification, Requires Adjustment, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Includes Valves View details Winning BidN/A Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next