BRITISH MEDICAL AUCTIONS January 2021 Timed Endoscopy Equipment Auction *Ending Friday 22nd January* (#2640) 15/01/2021 1:20 PM GMT - 22/01/2021 2:01 PM GMT CLOSED Starts Ending 22/01/2021 1:00 PM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-55 of 55. Previous|1|Next Lot 1 Pentax EC-3840L Colonoscope with Waterproof Cap in Case - Engineer's Report - Optical System - Untested Due to No Processor, Angulation - No Fault Fou View details StatusUnsold Lot 2 Olympus CYF-3 Cystoscope in Carry Case - Engineer's Report : Optics - No Broken Fibres, No Fault Found, Angulation - Down Short of Specification, Requ View details StatusUnsold Lot 3 Pentax FNL-10RBS Intubation Scope - Engineer's Report : Optics -Much Dirt Around Mask Edge, Angulation - No Fault Found , Insertion Tube - Torn at Gri View details Winning BidN/A Lot 4 Pentax VSB-2900 Gastroscope In Case *Mfd 2000* Engineer's Report - Optical System - Intermittent, Angulation - Not Reaching Specification, Insertion T View details Winning BidN/A Lot 5 Olympus LF-DP Laryngoscope in Case - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush Marks, View details Winning BidN/A Lot 6 Olympus ENF Type GP Nasopharyngoscope with Light Guide Adapter in Case - Engineer's Report : Optical System - 5 Broken Fibers, Angulation - No Fault F View details Winning BidN/A Lot 7 Olympus CYF-3 Fiber Optic Cystoscope in Case - Engineer's Report : Optical System - Bad Fluid Stain and Approximately 30 Broken Fibers, Angulation - S View details StatusUnsold Lot 8 Olympus CYF-3 Fiber Optic Cystoscope in Case - Engineer's Report : Optical System - Severe Fluid Stain, Angulation - Not Reaching Specification, Inser View details Winning BidN/A Lot 9 Fujinon EY-470S/B Video Cystoscope in Case with Accessories - Engineer's Report : Optical System - Image Interference, Angulation - No Fault Found, In View details Winning BidN/A Lot 10 Fujinon EY-470S/B Video Cystoscope in Case with Accessories - Engineer's Report : Optical System - Image Interference, Angulation - No Fault Found, In View details Winning BidN/A Lot 11 Fujinon EB-470T Video Bronchoscope in Case with Accessories - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insert View details Winning BidN/A Lot 12 Fujinon EG-530WR Video Gastroscope In Case - Engineers Report : Optics - No Fault Found, Angulation- No Fault Found, Patient Tube - No Fault Found, Li View details Winning BidN/A Lot 13 Olympus CF 230L Colonoscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light View details Winning BidN/A Lot 14 LSVP E-22VGS 99X17 1.6 Metre Scope in Case - Engineers Report : Optics - 60+ Broken Fibers and Bad Fluid Stain, Angulation - Satisfactory, Insertion T View details StatusUnsold Lot 15 Olympus CF-P20L Colonoscope in Case - Engineer's Report : Optics - 70+ Broken Fibers and Severe Fluid Stain, Angulation - Bending Section Strained, No View details StatusUnsold Lot 16 Olympus CYF-4 Cystoscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - Strained, Light Transmis View details Winning BidN/A Lot 17 Olympus CYF Type V Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - Not Reaching Specification, Insertion Tube - Dull a View details Winning BidN/A Lot 18 Olympus CF-H260DL Colonoscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Lig View details Winning BidN/A Lot 19 Olympus CF-H260DL Colonoscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Lig View details StatusUnsold Lot 20 Olympus GIF-H260 Gastroscope in Case - Engineer's Report : Optics - Condensation in Optics, Angulation - Not Reaching Specification, Requires Adjustme View details StatusUnsold Lot 21 Olympus GIF-H260 Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Ligh View details Winning BidN/A Lot 22 Olympus CYF-3 Cystoscope in Case - Engineer's Report : Optics - 1 x Broken Fiber, Angulation - Not Reaching Specification, Insertion Tube - Sleeving P View details Winning BidN/A Lot 23 Olympus ENF Type L3 Intubation Scope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Fou View details Winning BidN/A Lot 24 Pentax FB-15RBS Bronchoscope in Case - Engineer's Report : Optics - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - Minor Flat Mark, L View details Winning BidN/A Lot 25 Pentax FB-I5V Bronchoscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light View details Winning BidN/A Lot 26 Pentax ECY-1570K Cystoscope - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - Worn, Light Transmission - N View details Winning BidN/A Lot 27 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Ligh View details Winning BidN/A Lot 28 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Ligh View details Winning BidN/A Lot 29 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinks and Worn, Ligh View details Winning BidN/A Lot 30 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - Strained, Insertion Tube - Worn, Light Transmission - View details Winning BidN/A Lot 31 Pentax ECY-1530 Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kink at Grip, Light T View details Winning BidN/A Lot 32 Pentax ECY-1575K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Ligh View details Winning BidN/A Lot 33 Pentax ECY-1570 Cystoscope in Case - Engineer's Report : Optics - Unable to Check - Angulation - No Fault Found, Insertion Tube - No Fault Found, Ligh View details Winning BidN/A Lot 34 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - Kinks and Worn, Ligh View details Winning BidN/A Lot 35 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - Strained, Insertion Tube - Worn, Light Transmission - View details Winning BidN/A Lot 36 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - Minor Kink, Light Tr View details Winning BidN/A Lot 37 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - Minor Kink, Light Tr View details Winning BidN/A Lot 38 Pentax ECY-1570K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - Minor Kink Midway, L View details Winning BidN/A Lot 39 Pentax ECY-1575K Cystoscope in Case - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Ligh View details Winning BidN/A Lot 40 Pentax ECY-1570K Cystoscope - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transm View details Winning BidN/A Lot 41 Pentax ECY-1570K Cystoscope - Engineer's Report : Optics - Unable to Check, Angulation - No Fault Found, Insertion Tube - Slightly Worn, Light Transmi View details Winning BidN/A Lot 42 Fujinon EG-530NW Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - Poly Coating B View details Winning BidN/A Lot 43 Fujinon EG-450WR5 Video Colonoscope - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light View details Winning BidN/A Lot 44 Fujinon EG-530NW Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - Bending Section Strained, Not Reaching Specific View details Winning BidN/A Lot 45 Fujinon EC-450WL5 Video Colonoscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - Not Reaching Specification, Bending Section St View details Winning BidN/A Lot 46 Fujinon EC-450WL5 Video Colonoscope in Case - Engineer's Report : Optics - No Fault Found but Function Buttons Inoperative, Angulation - Not Reaching View details Winning BidN/A Lot 47 Fujinon EG-450WR5 Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Indenta View details Winning BidN/A Lot 48 Fujinon EG-450WR5 Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - Poly Coating View details Winning BidN/A Lot 49 Fujinon EG-530NW Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - Not Reaching Specification, Requires Adjustment View details Winning BidN/A Lot 50 Fujinon EG-450WR5 Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found but Function Buttons Inoperative, Angulation - No Fault Foun View details Winning BidN/A Lot 51 Fujinon EG-530NW Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - Not Reaching Specification, Requires Adjustment View details StatusUnsold Lot 52 Fujinon EG-530NW Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 53 Fujinon EG-530N Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - Not Reaching Specification, Requires Adjustment, View details Winning BidN/A Lot 54 Fujinon EG-530N Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Bite Mark View details Winning BidN/A Lot 55 Fujinon EG-530N Video Gastroscope in Case - Engineer's Report : Optics - No Fault Found, Angulation - Not Reaching Specification, Requires Adjustment, View details Winning BidN/A Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next