BRITISH MEDICAL AUCTIONS March 2025 Endoscopes and Endoscopy Equipment (#1106) 21/03/2025 11:00 AM GMT - 28/03/2025 3:32 PM GMT CLOSED Starts Ending 28/03/2025 11:08 AM GMT Sale closedView details Auction info BRITISH MEDICAL AUCTIONS Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViewsDefaultDefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Lot Number Filter By Categories Category match ANY of the aboveALL of the aboveANY of the aboveANY of the aboveALL of the above Featured Price Exclude closed lots View Search ▼ Results: Viewing items 101-137 of 137. Previous|12|Next Items per page 102550100100 Lot 101 Olympus Visera A50000A Endoeye 10mm 0 Degree Video Laparoscope in Case View details Winning BidN/A Lot 102 Karl Storz Hopkins 27005 CA 70 Degree 4.0mm 302mm Length Cystoscope in Box - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 103 Karl Storz Hopkins 27005 CA 70 Degree 4.0mm 302mm Length Cystoscope in Tray - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 104 Karl Storz 8705 CKA 70 Degree 4.0mm 175mm Length ENT Scope in Tray - Engineer's Report : Optical System - Blurry, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 105 Karl Storz 7230 CA 70 Degree 4.0mm 165mm Length ENT Scope in Tray - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 106 Karl Storz 7218 BA 30 Degree 2.7mm 119mm Length ENT Scope in Tray - Engineer's Report : Optical System - Lens Damage 30% Loss of Image, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 107 Karl Storz 7218 BA 30 Degree 2.7mm 195mm Length ENT Scope in Tray - Engineer's Report : Optical System - Slightly Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 108 Karl Storz 7208 BA 30 Degree 2.7mm 115mm Length ENT Scope in Tray - Engineer's Report : Optical System - Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 109 Karl Storz 8705 CKA 70 Degree 4.0mm 165mm Length Arthroscope in Tray - Engineer's Report : Optical System - Slightly Cloudy, Light Transmission - 30% Loss, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 110 Karl Storz 7207 BA 30 Degree 2.7mm 115mm Length ENT Scope in Case - Engineer's Report : Optical System - Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 111 Karl Storz 7218 BA 30 Degree 2.7mm 195cm Length ENT Scope in Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 112 Karl Storz 7218 BA 30 Degree 2.7mm 195mm Length ENT Scope in Tray - Engineer's Report : Optical System - Slightly Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 113 Karl Storz 7218 BA 30 Degree 2.7mm 195mm Length ENT Scope in Tray - Engineer's Report : Optical System - No Image, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 114 Microscopix 30 Degree 2.7mm ENT Scope in Tray - Engineer's Report : Optical System - Blurry Image, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 115 Karl Storz 7218 BA 30 Degree 2.7mm 195mm Length ENT Scope in Case - Engineer's Report : Optical System - 50% Image Missing, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 116 Microscopix 70 Degree 4.0mm 165mm Length ENT Scope in Tray - Engineer's Report : Optical System - Slightly Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *IPS* View details StatusUnsold Lot 117 Karl Storz 2705 CKA 70 Degree 4.0mm 165mm Length Arthroscope in Tray - Engineer's Report : Optical System - Cloudy, Light Transmission - 30% Loss, Insertion Tube - No Fault Found *IPS* View details Winning BidN/A Lot 118 Richard Wolf 4840.501 30 Degree 10.0mm 290mm Laparoscope - Engineer's Report : Optical System - Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 119 Dyonics 720592 30 Degree 150mm Length Arthroscope with Light Cable and Smith & Nephew 470H Camera in Tray - Engineer's Report : Optical System - Untested, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 120 Rudolf 0360-48130 30 Degree 2.7mm 330mm Length Hysteroscope in Box - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - Slight Dent View details Winning BidN/A Lot 121 Richard Wolf 6854.402 25 Degree 4.0mm 330mm Length Cystoscope in Box - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 122 Gimmi Alphascope GM540A 0 Degree 1.9mm 330mm Length Hysteroscope in Box - Engineer's Report : Optical System - Dirt Marks in Image, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 123 Gimmi Alphascope GM540A 0 Degree 1.9mm 330mm Length Hysteroscope in Box - Engineer's Report : Optical System - No Fault Found, Light Transmission - Slight Damage, Insertion Tube - No Fault Found View details Winning BidN/A Lot 124 Olympus A4677A 30 Degree 1.9mm 330mm Length Hysteroscope in Box - Engineer's Report : Optical System - Slightly Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 125 Richard Wolf Panoview 8650.435 70 Degree 4.0mm 330mm Length Cystoscope in Box - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 126 Gimmi Alphascope GM540A 0 Degree 1.9mm 330mm Length Hysteroscope in Box - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 127 Karl Storz 27005 CA 70 Degree 4.0mm 330mm Length Cystoscope in Box - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 128 ASAP HD 48963 0 Degree 2.0mm 60mm Length ENT Scope with Cover - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 129 Olympus A70961A 30 Degree 2.7mm 160mm Length ENT Scope in Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 130 ASAP HD 459231 30 Degree 2.7mm 125mm Length ENT Scope in Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 131 ASAP HD 48963 0 Degree 2.7mm 125mm Length ENT Scope with Cover - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 132 Olympus WA49601A 30 Degree 4.0mm 150mm Length Arthroscope in Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 133 Olympus WA49601A 30 Degree 4.0mm 150mm Length Arthroscope - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 134 Olympus WA96621A 30 Degree 4.0mm 150mm Length Arthroscope in Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 135 Olympus WA96621A 30 Degree 4.0mm 150mm Length Arthroscope - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 136 Olympus A70961A 30 Degree 2.7mm 170mm Length Arthroscope in Case - Engineer's Report : Optical System - Slightly Dark, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 137 Olympus A70961A 30 Degree 2.7mm 170mm Length Arthroscope in Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Items per page 102550100100 Previous|12|Next Previous 122 Next Previous 122 Next