BRITISH MEDICAL AUCTIONS January 2025 Endoscopy Equipment (#1064) 21/01/2025 4:00 PM GMT - 27/01/2025 1:30 PM GMT CLOSED Starts Ending 27/01/2025 10:04 AM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-98 of 98. Previous|1|Next Lot 1 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2344327* View details Winning BidN/A Lot 2 Olympus TJF-240 Video Duodenoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Bending Rubber, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Excessive From Bending Section *SN 2030189* View details Winning BidN/A Lot 3 Olympus XGIF-N240Y1 Prototype Gastroscope - Engineer's Report : Optical System - No Image, Angulation - No Fault Found , Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - Restricted Biopsy Channel , Leak Check - No Fault Found *SN A1432* View details Winning BidN/A Lot 4 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2800177* View details Winning BidN/A Lot 5 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Play In Controls Not Reaching Specification - To Be Adjusted , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Excessive Body Leak *SN 2-33672* View details Winning BidN/A Lot 6 Olympus LF-2 Laryngoscope - Engineer's Report : Optical System - 3 Broken Fibers, Angulation - No Fault Found , Insertion Tube - Kinked at Grip , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2512784* View details StatusUnsold Lot 7 Olympus BF-XT30 Fiber Bronchoscope - Engineer's Report : Optical System - Broken Fibers, Angulation - No Fault Found , Insertion Tube - Kinked at Grip and Minor Crush , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2500617* View details StatusUnsold Lot 8 Olympus GIF-XP260N Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2017266* View details Winning BidN/A Lot 9 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2035066* View details Winning BidN/A Lot 10 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2800174* View details Winning BidN/A Lot 11 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2800171* View details Winning BidN/A Lot 12 Olympus GF-UCT240 Ultrasound Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1900237* View details Winning BidN/A Lot 13 Olympus GIF-IT240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - L-R Brake Faulty, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2030118* View details Winning BidN/A Lot 14 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - Intermittent Plug Leak, Channels - No Fault Found, Leak Check - Plug Leak *SN 2834288* View details Winning BidN/A Lot 15 Olympus GIF-XQ260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2035078* View details Winning BidN/A Lot 16 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Strained L/R Brake Faulty, Insertion Tube - Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2033671* View details Winning BidN/A Lot 17 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2846733* View details Winning BidN/A Lot 18 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2846691* View details Winning BidN/A Lot 19 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification, Play in Control - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2500992* View details Winning BidN/A Lot 20 Olympus GIF-2T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2830960* View details Winning BidN/A Lot 21 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2846738* View details Winning BidN/A Lot 22 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2846617* View details Winning BidN/A Lot 23 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - No Image, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2500991* View details Winning BidN/A Lot 24 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2800173* View details Winning BidN/A Lot 25 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2011385* View details Winning BidN/A Lot 26 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted Play in Controls , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2800188* View details Winning BidN/A Lot 27 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 28466775* View details Winning BidN/A Lot 28 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found , Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2800184* View details Winning BidN/A Lot 29 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Monor Kink at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2410128* View details Winning BidN/A Lot 30 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2622929* View details Winning BidN/A Lot 31 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2557735* View details Winning BidN/A Lot 32 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2845995* View details Winning BidN/A Lot 33 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2735640* View details Winning BidN/A Lot 34 Olympus PCF-P240AL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Badly Strained, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2400141* View details Winning BidN/A Lot 35 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - Not Reaching Specification - To be Adjusted, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2512102* View details StatusUnsold Lot 36 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2847123* View details Winning BidN/A Lot 37 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2846993* View details Winning BidN/A Lot 38 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900422* View details Winning BidN/A Lot 39 Olympus ENF GP Pharyngoscope In Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2812880* View details Winning BidN/A Lot 40 Olympus ENF-GP Pharyngoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2612672* View details Winning BidN/A Lot 41 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN View details StatusUnsold Lot 42 Fujinon Paediatric Colonoscope (I.D Missing) - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked at Body, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2C377A017* View details Winning BidN/A Lot 43 Olympus MH-247 Ultrasonic Probe Set - Engineers Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 1911499* View details StatusUnsold Lot 44 Olympus 290 Series Twin Stack System Including 1 x Olympus WM-NP2 Stack Trolley with Olympus OEV262H Monitor, Olympus Evis Lucera Elite CV-290, Olympus Evis Lucera Elite CLV-290SL, Olympus UPD-3, Olympus OFP-2 and Sony Printer and 1 x Olympus WM-NP2 Stack Trolley with Olympus OEV262H Monitor (Powers Up, Scope Used for Demonstration Purposes Only, Scope Not Included) *7982733 / 7982734* View details Winning BidN/A Lot 45 Fujinon EG29-i10 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *A110461* View details Winning BidN/A Lot 46 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report : Optical System - Blurred Image, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2336873* View details Winning BidN/A Lot 47 Olympus PCF-240S Video Sigmoidoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2500193* View details Winning BidN/A Lot 48 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - Air/Water Outlet Tip Missing, Leak Check - No Fault Found *2913391* View details Winning BidN/A Lot 49 Olympus ENF-P4 Pharyngoscope in Case - Engineer's Report : Optical SYstem - 5 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks, Light Transmission - No Fault Found, Leak Check - No Fault Found *W211977* View details StatusUnsold Lot 50 Olympus LF-TP Laryngoscope in Case - Engineer's Report : Optical System - 2 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W901008* View details Winning BidN/A Lot 51 Olympus LF-GP Laryngoscope in Fujinon Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W000991* View details Winning BidN/A Lot 52 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Wrinkles Present Near Body, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2610404* View details Winning BidN/A Lot 53 Karl Storz 11278 A1 Urethroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak from Insertion Tube *2203869* View details Winning BidN/A Lot 54 Karl Storz 11278 A1 Urethroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Bending Section Rubber and Crush Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak from Insertion Tube *2224650* View details Winning BidN/A Lot 55 Olympus ENF-GP Pharyngoscope with Mini Light Source - Engineer's Report : Optical System - 6 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found, Other Comments - Light Source Untested Due to No Batteries *W901931* View details Winning BidN/A Lot 56 Olympus ENF-GP Pharyngoscope with Mini Light Source - Engineer's Report : Optical System - Minor Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found, Other Comments - Light Source Untested Due to No Batteries *W901932* View details Winning BidN/A Lot 57 Olympus ENF-GP Pharyngoscope with Mini Light Source - Engineer's Report : Optical System - 2 x Broken Fibers, Angulation - No Fault Found, Insertion Tube - Kinks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found, Other Comments - Light Source Untested Due to No Batteries *W901923* View details Winning BidN/A Lot 58 Olympus ENF-GP Pharyngoscope with Mini Light Source - Engineer's Report : Optical System - Minor Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Leak Check - No Fault Found, Other Comments - Light Source Untested Due to No Batteries *W901934* View details Winning BidN/A Lot 59 Olympus ENF-GP Pharyngoscope with Mini Light Source - Engineer's Report : Optical System - 2 x Broken Fibers and Minor Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks Present, Light Transmission - No Fault Found, Leak Check - No Fault Found, Other Comments - Light Source Untested Due to No Batteries *W901736* View details StatusUnsold Lot 60 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 61 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 62 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 63 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 64 Stryker 1488HD Camera Ref 1488310130 (Tested Working - See Photos) View details StatusUnsold Lot 65 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - Not Reaching Specification - Strained Bending Section, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W040685* View details StatusUnsold Lot 66 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W341331* View details Winning BidN/A Lot 67 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W341335* View details Winning BidN/A Lot 68 Olympus CYF-V2 Video Cystoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W341336* View details Winning BidN/A Lot 69 Olympus CF-240DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300091* View details Winning BidN/A Lot 70 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1300205* View details Winning BidN/A Lot 71 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *1400267* View details StatusUnsold Lot 72 Olympus BF-260 Video Bronchoscope - Engineer's Report : Optical System - No Fault FOund, Angulation - No Fault Found, Insertion Tube - Crush Marks Present, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2501002* View details Winning BidN/A Lot 73 74 x Defendo Disposable Air/Water, Suction and Biopsy Valves for Pentax 90 Series G1 Endoscopes (All Expire 10/2026) *BRE* View details Winning BidN/A Lot 74 Olympus LF-TP Laryngoscope in Case - Engineer's Report : Optical System - 1 x Broken Fiber, Angulation - No Fault Found, Insertion Tube - Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *W901009* View details Winning BidN/A Lot 75 Karl Storz 11278 A1 Urethroscope in Case - Engineer's Report : Optical System - 4 Broken Fibers and Fluid Stain Present, Angulation - Distorted, Insertion Tube - No Bending Section Rubber, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leaking Insertion Tube *2207187* View details Winning BidN/A Lot 76 Karl Storz 11272 VN Video Cystoscope in Case - Engineer's Report : Optical System - See Photo, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Serial Number Erased View details Winning BidN/A Lot 77 Karl Storz 11272 VN Video Cystoscope in Case - Engineer's Report : Optical System - See Photo, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Serial Number Erased View details Winning BidN/A Lot 78 Karl Storz 11272 VNU Video Cystoscope in Case - Engineer's Report : Optical System - See Photo, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Serial Number Erased View details Winning BidN/A Lot 79 Karl Storz 11272 VN Video Cystoscope in Case - Engineer's Report : Optical System - See Photo, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Serial Number Erased View details Winning BidN/A Lot 80 Karl Storz 11272 VN Video Cystoscope in Case - Engineer's Report : Optical System - See Photo, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Serial Number Erased View details Winning BidN/A Lot 81 Karl Storz 11272 VN Video Cystoscope in Case - Engineer's Report : Optical System - See Photo, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Serial Number Erased View details Winning BidN/A Lot 82 Karl Storz 11272 VN Video Cystoscope in Case - Engineer's Report : Optical System - See Photo, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found, Other Comments - Serial Number Erased View details Winning BidN/A Lot 83 Olympus CYF-240 Video Cystoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2400921* View details Winning BidN/A Lot 84 Olympus BF-P60 Bronchoscope in Case - Engineer's Report : Optical System - 2 x Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - E.T.O Valve Jammed *2802119* View details Winning BidN/A Lot 85 Olympus JF-V2 Video Duodenoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Excessive Play, Not Reaching Specification, Insertion Tube - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2700031* View details Winning BidN/A Lot 86 Olympus BF-P60 Bronchoscope in Case - Engineer's Report : Optical System - 3 x Broken Fibers and Fluid Stain Present, Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2143862* View details Winning BidN/A Lot 87 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *2300757* View details Winning BidN/A Lot 88 Job Lot Including 1 x Olympus WA91502A Mini Light Source, 1 x Pentax BS-LH2 Mini Light Source, 1 x Olympus MAJ922 Mini Light Source and 1 x Olympus WA03200A S Light Source Cable in Case (All Untested) View details Winning BidN/A Lot 89 Dale 301 Rigid Scope Tester in Tray View details Winning BidN/A Lot 90 Corin 4.0mm Diameter 70 Degree 185mm Length Arthroscope in Case - Engineer's Report : Optical System - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *510.470* **HOL** View details Winning BidN/A Lot 91 Richard Wolf Panoview 8934.441 10.0mm Diameter 0 Degree 310mm Length Laparoscope in Box - Engineer's Report : Optical Image - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found *42901* View details Winning BidN/A Lot 92 Olympus A4674A 2.7mm Diameter 30 Degree 302mm Length Cystoscope - Engineer's Report : Optical Image - Cloudy, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 93 Olympus A4674A 2.9mm Diameter 30 Degree 302mm Length Cystoscope in Box - Engineer's Report : Optical Image - No Image, Light Transmission - No Fault Found, Insertion Tube - 1 x Dent Present View details Winning BidN/A Lot 94 Richard Wolf 893.4461 Panoview Ultra 10.0mm Diameter 0 Degree 315mm Length Laparoscope in Box - Engineer's Report : Optical Image - No Image, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 95 Karl Storz 10320 AA 5.4mm Diameter 0 Degree 50cm Bronchoscope in Case - Engineer's Report : Optical Image - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 96 Karl Storz 10320 BA 5.4mm Diameter 30 Degree 50cm Bronchoscope in Case - Engineer's Report : Optical Image - No Fault Found, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 97 Clarus 5197-200 4.7mm Diameter 0 Degree 250mm Bronchoscope - Engineer's Report : Optical Image - Out of Focus, Light Transmission - No Fault Found, Insertion Tube - No Fault Found View details Winning BidN/A Lot 98 Karl Storz Image 1 X-Link HD TC 301 Unit (Powers Up) *SN SU732709-P* View details StatusUnsold Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next