December 2024 Endoscopy Part 2 17/12/2024 1:00 PM GMT - 27/12/2024 11:49 PM GMT View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-100 of 110. Previous|12|Next Image Lot # Item Title Time Left Your Bids 1 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2622202* 1 Starting£ 500 Login to bidLogin to buy 2 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Monor Kink at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2410128* 1 Starting£ 500 Login to bidLogin to buy 3 Olympus CF-H260DL Video Colonoscope in Case Engineer's - Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900425* 1 Login to bidLogin to buy 4 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2557732* 1 Starting£ 500 Login to bidLogin to buy 5 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2040153* 1 Starting£ 500 Login to bidLogin to buy 6 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinked at Grip , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2211516* 1 Starting£ 500 Login to bidLogin to buy 7 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Excessive Play Left Right - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2400908* 1 Starting£ 500 Login to bidLogin to buy 8 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bad Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2846836* 1 Login to bidLogin to buy 9 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2557748* 1 Login to bidLogin to buy 10 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2622222* 1 Starting£ 500 Login to bidLogin to buy 11 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2611652* 1 Starting£ 500 Login to bidLogin to buy 12 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2732291* 1 Starting£ 500 Login to bidLogin to buy 13 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2911238* 1 Starting£ 500 Login to bidLogin to buy 14 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2622929* 1 Login to bidLogin to buy 15 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2557735* 1 Login to bidLogin to buy 16 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2934564* 1 Login to bidLogin to buy 17 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2732292* 1 Starting£ 500 Login to bidLogin to buy 18 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2948033* 1 Login to bidLogin to buy 19 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2141267* 1 Login to bidLogin to buy 20 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2622221* 1 Starting£ 500 Login to bidLogin to buy 21 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN- Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2845995* 1 Login to bidLogin to buy 22 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN- Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2735640* 1 Login to bidLogin to buy 23 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - Number One Button Not Working, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900440* 1 Starting£ 500 Login to bidLogin to buy 24 Olympus PCF-P240AL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Badly Strained, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2400141* 1 Login to bidLogin to buy 25 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - Not Reaching Specification - To Be Adjusted, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2800206* 1 Starting£ 500 Login to bidLogin to buy 26 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - Not Reaching Specification - To be Adjusted, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2512102* 1 Starting£ 500 Login to bidLogin to buy 27 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2411913* 1 Starting£ 500 Login to bidLogin to buy 28 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2510166* 1 Starting£ 300 Login to bidLogin to buy 29 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2800168* 1 Login to bidLogin to buy 30 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2846991* 1 Login to bidLogin to buy 31 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2400909* 1 Login to bidLogin to buy 32 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2710796* 1 Starting£ 500 Login to bidLogin to buy 33 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kink at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2847123* 1 Starting£ 500 Login to bidLogin to buy 34 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2846993* 1 Login to bidLogin to buy 35 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2811073* 1 Starting£ 500 Login to bidLogin to buy 36 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2811075* 1 Starting£ 500 Login to bidLogin to buy 37 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - 2 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W906840* 1 Starting£ 100 Login to bidLogin to buy 38 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - 6 Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W459088** 1 Starting£ 100 Login to bidLogin to buy 39 Olympus GIF-XQ260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2723564* 1 Login to bidLogin to buy 40 Pentax FNL-10RBS Rhinolaryngoscope in Case - Engineer's Report : Optical System - Excessive Fluid Contamination / No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 113520* 1 Starting£ 10 Login to bidLogin to buy 41 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2622203* 1 Starting£ 500 Login to bidLogin to buy 42 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2512090* 1 Starting£ 500 Login to bidLogin to buy 43 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2412032* 1 Starting£ 500 Login to bidLogin to buy 44 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2634309* 1 Starting£ 500 Login to bidLogin to buy 45 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Image, Interference, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2622220* 1 Login to bidLogin to buy 46 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2634308* 1 Login to bidLogin to buy 47 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2948027* 1 Login to bidLogin to buy 48 Olympus CF-H260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900422* 1 Login to bidLogin to buy 49 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - Kinks in Light Guide Tube at Plug End, Channels - No Fault Found, Leak Check - No Fault Found *SN 2411956* 1 Starting£ 400 Login to bidLogin to buy 50 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - Kinks in Light Guide Tube at Plug End, Channels - No Fault Found, Leak Check - No Fault Found *SN 2710814** 1 Starting£ 500 Login to bidLogin to buy 51 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - Kinks in Light Guide Tube at Plug End, Channels - No Fault Found, Leak Check - No Fault Found *SN 2211517* 1 Starting£ 500 Login to bidLogin to buy 52 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2668414* 1 Login to bidLogin to buy 53 Olympus BF-F260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1400388* 1 Starting£ 200 Login to bidLogin to buy 54 Olympus BF 240 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1140750* 1 Login to bidLogin to buy 55 Olympus BF-IT260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2700940* 1 Starting£ 200 Login to bidLogin to buy 56 Pentax EC34-i10F Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110085* 1 Starting£ 400 Login to bidLogin to buy 57 Pentax EC34-i10F Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110084* 1 Starting£ 400 Login to bidLogin to buy 58 Pentax EC34-i10F Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - Excess Play, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110054* 1 Starting£ 300 Login to bidLogin to buy 59 Pentax EG29-i10 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110449* 1 Starting£ 400 Login to bidLogin to buy 60 Pentax EC38-i10L Video Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110108* 1 Starting£ 500 Login to bidLogin to buy 61 Pentax EG29-i10 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110458* 1 Starting£ 500 Login to bidLogin to buy 62 Pentax EC34-i10F Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - Down Movement Strained, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110068* 1 Starting£ 500 Login to bidLogin to buy 63 Pentax EC38-i10L Video Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1 Starting£ 500 Login to bidLogin to buy 64 Pentax EG29-i10 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Strained , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110241* 1 Starting£ 500 Login to bidLogin to buy 65 Pentax EC34-i10F Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - Play Evident, Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 110070* 1 Starting£ 500 Login to bidLogin to buy 66 Pentax EG-3490K Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A120172* 1 Starting£ 500 Login to bidLogin to buy 67 Pentax EG29-i10 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - Excessive Play Strained Bending Section, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1 Starting£ 300 Login to bidLogin to buy 68 Pentax EC34-i10F Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110067* 1 Starting£ 500 Login to bidLogin to buy 69 Pentax EG27-i10 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110219* 1 Starting£ 500 Login to bidLogin to buy 70 Pentax ECY-1575K Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Bad Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN H120313* 1 Starting£ 100 Login to bidLogin to buy 71 Pentax ECY-1575K Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Body Grip Loose and Leaking, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Leak at Body Grip *SN G120112* 1 Starting£ 100 Login to bidLogin to buy 72 Olympus CF-240L Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Kink at Grip, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900380* 1 Login to bidLogin to buy 73 Pentax EC34-i10F Colonoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Bending Section Strained, Insertion Tube - Tube Strained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110069* 1 Starting£ 200 Login to bidLogin to buy 74 Pentax EG29-i10 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - Minor Crush Mark @ 70cms , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110422* 1 Starting£ 400 Login to bidLogin to buy 75 Pentax ECY-1575K Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Crush Marks in Bending Section, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN G120110* 1 Starting£ 100 Login to bidLogin to buy 76 Pentax EC34-i10F Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A11009* 1 Starting£ 500 Login to bidLogin to buy 77 Pentax EC-3490Li Video Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - Badly Strained, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110730* 1 Starting£ 400 Login to bidLogin to buy 78 Pentax EG29-i10 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - Down Not Reaching Specification / To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A110453* 1 Starting£ 500 Login to bidLogin to buy 79 Olympus CF-240L Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2030391* 1 Login to bidLogin to buy 80 Olympus TJF-240 Video Duodenoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2431076* 1 Login to bidLogin to buy 81 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2344307* 1 Login to bidLogin to buy 82 Olympus PCF-240S Video Sigmoidoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2700250* 1 Login to bidLogin to buy 83 Olympus GIF-XQ240 Video Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2133973* 1 Login to bidLogin to buy 84 Olympus CF-240AL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Bending Section Strained, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2110199* 1 Login to bidLogin to buy 85 Olympus CF-240AL Video Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2110247* 1 Login to bidLogin to buy 86 Olympus GIF-2T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Kinked at Grip , Light Transmission - No Fault Found, Channels - Biopsy Channel Raiser Seized, Leak Check - No Fault Found *SN 29441404* 1 Login to bidLogin to buy 87 Olympus CYF Type V2 Video Cystoscope in Case - Engineer's Report : Optical System - Unable to Check, Angulation - Strained - To Be Adjusted, Insertion Tube - Kinks at Grip , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W341263* 1 Starting£ 100 Login to bidLogin to buy 88 Olympus PCF-240S Video Sigmoidoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2700251* 1 Login to bidLogin to buy 89 Olympus ENF-P4 Pharyngoscope In Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2612662* 1 Starting£ 40 Login to bidLogin to buy 90 Olympus ENF GP Pharyngoscope In Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2812880* 1 Starting£ 40 Login to bidLogin to buy 91 Olympus ENF-GP Pharyngoscope in Case - Engineer's Report : Optical System - Excessive Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2612672* 1 Starting£ 40 Login to bidLogin to buy 92 Karl Storz 11274AA1 Ureteroscope in Case - Engineer's Report : Optical System - 1 Broken Fiber , Angulation - Not Reaching Specification, Insertion Tube - Crush Mark , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 207651* 1 Login to bidLogin to buy 93 Olympus CF-Q260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2811074* 1 Starting£ 500 Login to bidLogin to buy 94 Olympus LF-GP Laryngoscope - Engineer's Report : Optical System - 0 Broken Fibers, Angulation - No Fault Found, Insertion Tube - Crush Marks , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A800577* 1 Starting£ 30 Login to bidLogin to buy 95 Olympus CYF-4 Cystoscope - Engineer's Report : Optical System - Fluid Stain, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 101978* 1 Starting£ 30 Login to bidLogin to buy 96 Olympus CYF-4 Cystoscope - Engineer's Report : Optical System - Excess Fluid Stain, Angulation - No Fault Found, Insertion Tube - Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W101972* 1 Starting£ 30 Login to bidLogin to buy 97 Karl Storz 13806PKS Video - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN G28/34* 1 Starting£ 60 Login to bidLogin to buy 98 Olympus CYF-5 Cystoscope - Engineer's Report : Optical System - Broken Fibers, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1 Starting£ 60 Login to bidLogin to buy 99 Karl Storz 13925 PKS Video Colonoscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 03046* 1 Starting£ 200 Login to bidLogin to buy 100 Karl Storz 13820PKS Gastroscope - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 18325* 1 Starting£ 200 Login to bidLogin to buy Items per page 102550100 Previous|12|Next Previous 12 Next