BRITISH MEDICAL AUCTIONS December 2024 Endoscopy (#1043) 28/11/2024 11:00 AM GMT - 06/12/2024 3:02 PM GMT Starts Ending 06/12/2024 1:00 PM GMT Auction info BRITISH MEDICAL AUCTIONS View Search ▼ Items per page 102550100 Search Sort by DefaultTime LeftLot#Lot NameNewestHighest PriceLowest PriceBidsViews Filter By Categories Category match ANY of the aboveALL of the above Featured Exclude closed lots Price Lot Number Results: Viewing items 1-62 of 62. Previous|1|Next Lot 1 Olympus BF Type UC260F-OL8 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 1500034* Login to bid Starting£ 700 Lot 2 Olympus BF-IT260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN Login to bid Starting£ 300 Lot 3 Olympus BF-IT260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2302362* Login to bid Starting£ 300 Lot 4 Olympus GIF-H260Z Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2801820* Login to bid Lot 5 Olympus GIF-FCQ2602 Video Scope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2710212* Login to bid Starting£ 400 Lot 6 Olympus BF Type 6C260 Bronchoscope In Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Minor Crush to Reform, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900270* Login to bid Starting£ 100 Lot 7 Olympus BF-IT260 Video Bronchoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2302316* Login to bid Starting£ 300 Lot 8 Olympus GIF-XP260N Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2117412* Login to bid Starting£ 300 Lot 9 Olympus GIF-H260Z Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2011685* Login to bid Lot 10 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2244081* Login to bid Lot 11 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 290A622* Login to bid Starting£ 500 Lot 12 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 290474* Login to bid Lot 13 Fujinon EC-530WL Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 447A353* Login to bid Lot 14 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 29A461* Login to bid Lot 15 Fujinon EC-530WL Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 4547A323* (Model Badge Missing) Login to bid Lot 16 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Badly Kinked , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN N/A* (Model I.D Worn) Login to bid Lot 17 Fujinon EG-530WR Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN Worn Away* Login to bid Lot 18 Pentax EC-EC3890LK Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A1200887* Login to bid Starting£ 200 Lot 19 Pentax EC-EC3890LK Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A120065* Login to bid Starting£ 200 Lot 20 Pentax EC-EC3890LK Video Colonoscope - Engineer's Report : Optical System - No Image, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN Missing* Login to bid Starting£ 100 Lot 21 Pentax EC-EC3890LK Video Colonoscope (Scope In Dismantled Condition) *SN A120069* Login to bid Lot 22 Pentax EC-EC3890LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A120062* Login to bid Starting£ 200 Lot 23 Pentax EG-2970K Video Gastroscope in Case (Scope in Dismantled Condition) *SN A121474* Login to bid Lot 24 Pentax EG-2990K Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A120148* Login to bid Starting£ 500 Lot 25 Pentax EG-2990K Video Gastroscope in Case (Scope in Dismantled Condition) *SN A120217* Login to bid Lot 26 Pentax EG-2990K Video Gastroscope in Case (Scope in Dismantled Condition) *SN A120218* Login to bid Lot 27 Pentax EC-EC3890LK Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN A120472* Login to bid Starting£ 200 Lot 28 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 1 Broken Fibre / Misty, Angulation - No Fault Found, Insertion Tube - Crush and Kink Marks, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN W700814* Login to bid Lot 29 Olympus ENF-GP Pharyngoscope - Engineer's Report : Optical System - 1 Broken Fibre, Angulation - No Fault Found, Insertion Tube - Minor Kink , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2305580* Login to bid Lot 30 Olympus GIF-H260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2049288* Login to bid Starting£ 500 Lot 31 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2911348* Login to bid Starting£ 300 Lot 32 Olympus GIF-Q260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2532915* Login to bid Lot 33 Olympus CF-Q260DL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2510283* Login to bid Lot 34 Olympus GIF-1T240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Left / Right Brake Faulty, Insertion Tube - Minor Crush Mark , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2320536* Login to bid Starting£ 400 Lot 35 Olympus PCF-Q260AL Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Strained and Distorted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2910504* Login to bid Starting£ 300 Lot 36 Olympus GIF-IT240 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2930476* Login to bid Starting£ 200 Lot 37 Olympus BF-P260F Video Bronchoscope in Case - Engineer's Report : Optical System - 0 Broken Fibre / Minor Stain Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2700512* Login to bid Lot 38 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2200850* Login to bid Lot 39 Olympus CF-Q240L Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900357* Login to bid Lot 40 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2300855* Login to bid Lot 41 Olympus CF-H260DL Video Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2200699* Login to bid Starting£ 600 Lot 42 Olympus GIF-1T240 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - Kink at Body, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2030121* Login to bid Starting£ 300 Lot 43 Olympus CYF-240 Video Cystoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Strained, Insertion Tube - Crush Mark, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2100789* Login to bid Starting£ 100 Lot 44 Olympus BF-260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2601171* Login to bid Lot 45 Olympus GIF-XQ260 Video Gastroscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification - To Be Adjusted, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2913343* Login to bid Lot 46 Fujinon EC-530WL Colonoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 447A155* Login to bid Lot 47 Olympus MH-908 Ultrasound Probe - Engineer's Report : Optical System - Unable to Check , Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - Unable *SN Erased* Login to bid Starting£ 100 Lot 48 Olympus GIF-H260 Video Gastroscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2734789* Login to bid Starting£ 500 Lot 49 Fujinon EC-590WI4 Video Scope- Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 665d062* Login to bid Lot 50 Olympus BF-260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - Crush Mark at Body, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2701448* Login to bid Starting£ 100 Lot 51 ACMI AUR-7 Urethroscope in Case - Engineer's Report : Optical System - Bad Fluid Stain, Angulation - Not Reaching Specification, Insertion Tube - Torn Bending Section Rubber, Light Transmission - 50% Loss, Channels - No Fault Found, Leak Check - No Fault Found Login to bid Lot 52 Toshiba PEF-510SB Transesophageal Echo Probe - Engineer's Report : Optical System - Unable to Check, Angulation - No Fault Found (Requires Clean Due to Bad Connection) Login to bid Starting£ 5 Lot 53 Olympus CF-1T200L Video Colonoscope in Case - Engineer's Report : Optical System - No Fault Found, Angulation - Not Reaching Specification , Insertion Tube - Stained, Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2400170* Login to bid Lot 54 2 x Olmpsu VE-1 Endo Capsules with 1 x Recorder Cradle Login to bid Lot 55 Olympus BF-P60 Bronchoscope in Case - Engineers Report : Optical System - 2 Broken Fibres , Angulation - No Fault Found, Insertion Tube - Badly Kinked, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN Login to bid Starting£ 40 Lot 56 Olympus NPF-54 Pharyngoscope in Case - Engineers Report : Optical System - Stain , Angulation - No Fault Found, Insertion Tube - Sleeving Perished, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 710129* Login to bid Lot 57 Olympus ENF-P4 Pharyngoscope In Case - Engineers Report : Optical System - Speckled Fluid Stain, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - Tube Strained, Channels - No Fault Found Leak Check - No Fault Found *SN 1024380* Login to bid Lot 58 Olympus ENF-GP Pharyngoscope in Case - Engineers Report : Optical System - 9 Broken Fibres , Angulation - No Fault Found, Insertion Tube - Peeling, Leak From Tube, Tear Present, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - Leak From Tube *SN W505435* Login to bid Lot 59 Olympus MH-247 Ultrasonic Probe Set - Engineers Report : Optical System - Unable to Check, Angulation - No Fault Found, Insertion Tube - No Fault Found, Light Transmission - No Fault Found, Channels - No Fault Found Leak Check - No Fault Found *SN 1911499* Login to bid Starting£ 250 Lot 60 Baxter Model VS7530-P Universal Camera *Untested* Login to bid Lot 61 Olympus BF-F260 Video Bronchoscope - Engineer's Report : Optical System - No Fault Found, Angulation - No Fault Found, Insertion Tube - No Fault Found , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2900492* Login to bid Starting£ 400 Lot 62 Olympus TJF-240 Video Duodenoscope - Engineer's Report : Optical System - No Fault Found, Angulation - Play in Controls, Insertion Tube - Worn , Light Transmission - No Fault Found, Channels - No Fault Found, Leak Check - No Fault Found *SN 2541724* Login to bid Starting£ 400 Items per page 102550100 Previous|1|Next Previous 1 Next Previous 1 Next